http://www.tracopower.com
DC/DC Converters
TEN 40WIN Series 40 Watt
Input Specifications
Input current at no load 24 Vin; 3.3 & 5.0 VDC models: 90 mA typ.
(nominal input voltage) 24 Vin; 12 VDC models: 95 mA typ.
24 Vin; 15 & 24 VDC models: 105 mA typ. / 115 mA typ.
24 Vin; dual output models: 65 mA typ.
48 Vin; 3.3 & 5.0 VDC models: 55 mA typ.
48 Vin; 12 & 15 VDC models: 60 mA typ. / 65 mA typ.
48 Vin; 24 VDC models: 75 mA typ.
48 Vin; dual output models: 45 mA typ.
Surge voltage (100 msec. max.) 24 V models: 50 V max.
48 V models: 100 V max.
Reflected input ripple current 24 V models: 30 mA typ.
48 V models: 20 mA typ.
Conducted noise (input) EN 55022 level A, FCC part 15, level A with
external capacitor see: application note
Start-up voltage / under voltage shut down 24 V models: 9 VDC / 8.3 VDC (or lower)
48 V models: 18 VDC / 16.5 VDC (or lower)
Recommended input fuse (slow blow) 24 V models: 8000 mA
48 V models: 4000 mA
Output Specifications
Voltage set accuracy single output models: ±1.0 %
dual output models (balanced load): ±2.0 %
Output voltage adjustment range ±10 % with external resistor (see page 3)
Regulation – Input variation Vin min. to Vin max. ±0.5 % max.
– Load variation single output models (0 – 100%): ±0.5 % max.
dual output models (9 – 100%): ±1.0 % max.
Minimum load single output models: 0 %
dual output models: 9 % of rated max current
(operation at lower
load condition will not damage the converters.
However, they may not meet all listed specifications)
Temperature coefficient ±0.02 %/K
Ripple and noise (20 MHz Bandwidth) 3.3 & 5.0 VDC models: 100 mVpk-pk. typ.
with external capacitors 1 µF M/C 10 µF T/C other models: 150 mVpk-pk typ.
Transient response (25 % load step change) 250 µs typ.
Short circuit protection hiccup mode, indefinite (automatic recovery)
Over power protection at 150 %
Over voltage protection at 120 % of Vout nom. typ.
Capacitive load 3.3 VDC models: 21’000 µF max.
5.0 VDC models: 13’600 µF max.
12.0 VDC models: 2’400 µF max.
15.0 VDC models: 1’500 µF max.
24.0 VDC models: 600 µF max.
±12.0 VDC models: 1’200 µF max. (each output)
±15.0 VDC models: 750 µF max. (each output)
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Page 2 of 4
Application note: www.tracopower.com/overview/ten40win