AQ-N
ORDERING INFORMATION
TYPES
1. Standard type
High capacity SSR
up to 40A
with wide variation
AQ-N RELAYS
Type Load current Load voltage Part No.
Zero-cross type
10A
75 to 250V AC
AQN111
15A AQN211
20A AQN311
25A AQN411
40A AQN611
Random type
10A
75 to 250V AC
AQN121
15A AQN221
20A AQN321
25A AQN421
40A AQN621
FEATURES
1. Five types available from 10A to 40A
2. Built-in varistor
3. Includes operation LED (red)
4. Dielectric voltage of 4,000V
5. 4 to 32V DC input voltage
6. Both zero-cross and random types
available
TYPICAL APPLICATIONS
1. Molding machine (heater control)
2. Temperature controlled bath (heater
control)
3. Printing machines (heater control)
4. Wrapping and packing machine
(heater control)
5. Machine tools (Motor control)
Compliance with RoHS Directive
AQ-N Solid State Relays
Load current
1: 10 A
2: 15 A
3: 20 A
4: 25 A
6: 40 A
AQN
Load voltage
1: 75 to 250 V AC, Zero-cross
2: 75 to 250 V AC, Random
Function
Nil:
V:
L:
VL:
None
Built-in varistor
With LED indication
Built-in varistor and with LED indication
Input voltage
1: 4 to 32 V DC
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AQ-N
2. With LED indication type
3. With varistor type
4. With varistor and LED indication type
Standard packing; carton: 2 pcs., case: 100 pcs.
5. Accessories
RATINGS
1. Ratings (Measurement condition: at 20°C 68°F, Input ripple: 1% or less)
1) Zero-cross type
Notes: *1. Please refer to REFERENCE DATA, “3. Input current vs. input voltage”.
*2. Please refer to REFERENCE DATA, “1. Load current vs. ambient temperature”.
*3. Please refer to REFERENCE DATA, “2. Non-repetitive surge current vs. carrying time”.
*4. When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”.
Type Load current Load voltage Part No.
Zero-cross type
10A
75 to 250V AC
AQN111L
15A AQN211L
20A AQN311L
25A AQN411L
40A AQN611L
Random type
10A
75 to 250V AC
AQN121L
15A AQN221L
20A AQN321L
25A AQN421L
40A AQN621L
Type Load current Load voltage Part No.
Zero-cross type
10A
75 to 250V AC
AQN111V
15A AQN211V
20A AQN311V
25A AQN411V
40A AQN611V
Random type
10A
75 to 250V AC
AQN121V
15A AQN221V
20A AQN321V
25A AQN421V
40A AQN621V
Type Load current Load voltage Part No.
Zero-cross type
10A
75 to 250V AC
AQN111VL
15A AQN211VL
20A AQN311VL
25A AQN411VL
40A AQN611VL
Random type
10A
75 to 250V AC
AQN121VL
15A AQN221VL
20A AQN321VL
25A AQN421VL
40A AQN621VL
Type Part No. Packaged quantity
Standard heat sink (10A, 15A and 20A) AQP-HS-J10A 5 in a carton, 20 in a case
Standard heat sink (25A) AQP-HS-30/40A 5 in a carton, 20 in a case
Standard heat sink (40A) AQP-HS-J25A No carton, 5 in a case
Slim heat sink (45mm wide) (Mountable on a DIN rail) AQP-HS-SJ20A No carton, 8 in a case
DIN rail mounting plate AQP-DP 10 in a carton, 100 in a case
Te r minal cover AQP-NPC 2 in a carton, 100 in a case
Item
Type 10A 15A 20A 25A 40A Remarks
Part No.
AQN111
AQN111L
AQN111V
AQN111VL
AQN211
AQN211L
AQN211V
AQN211VL
AQN311
AQN311L
AQN311V
AQN311VL
AQN411
AQN411L
AQN411V
AQN411VL
AQN611
AQN611L
AQN611V
AQN611VL
Input side
Input voltage 4 to 32V *1
Input current Max. 20mA *1
Drop-out voltage Min. 1V
Output side
Max. load current 10A 15A 20A 25A 40A *2
Load voltage 75V to 250V
Frequency 45Hz to 65Hz
Non-repetitive surge current 100A 150A 200A 250A 400A In one cycle at 60Hz *3
Max. “OFF-state” leakage current Max. 10mA at 60Hz
Max. “ON-state” voltage drop 1.6V at Max. carrying current
Min. load current 100mA *4
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AQ-N
2) Random type
Notes: *1. Please refer to REFERENCE DATA, “3. Input current vs. input voltage”.
*2. Please refer to REFERENCE DATA, “1. Load current vs. ambient temperature”.
*3. Please refer to REFERENCE DATA, “2. Non-repetitive surge current vs. carrying time”.
*4. When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”.
2. Characteristics (Measurement condition: at 20°C 68°F, Input ripple: 1% or less)
1) Zero-cross type
2) Random type
Item
Type 10A 15A 20A 25A 40A Remarks
Part No.
AQN121
AQN121L
AQN121V
AQN121VL
AQN221
AQN221L
AQN221V
AQN221VL
AQN321
AQN321L
AQN321V
AQN321VL
AQN421
AQN421L
AQN421V
AQN421VL
AQN621
AQN621L
AQN621V
AQN621VL
Input side
Input voltage 4 to 32V *1
Input current Max. 20mA *1
Drop-out voltage Min. 1V
Output side
Max. load current 10A 15A 20A 25A 40A *2
Load voltage 75V to 250V
Frequency 45Hz to 65Hz
Non-repetitive surge current 100A 150A 200A 250A 400A In one cycle at 60Hz *3
Max. “OFF-state” leakage current Max. 10mA at 60Hz
Max. “ON-state” voltage drop 1.6V at Max. carrying current
Min. load current 100mA *4
Type 10A 15A 20A 25A 40A Remarks
Part No.
AQN111
AQN111L
AQN111V
AQN111VL
AQN211
AQN211L
AQN211V
AQN211VL
AQN311
AQN311L
AQN311V
AQN311VL
AQN411
AQN411L
AQN411V
AQN411VL
AQN611
AQN611L
AQN611V
AQN611VL
Operate time, max. 1/2 cycle of voltage sine wave + 1ms
Release time, max. 1/2 cycle of voltage sine wave + 1ms
Insulation resistance, min. 100M between input and output at 500 V DC
Breakdown voltage 4,000 Vrms between input and output; 2,500 Vrms between input, output and case for 1min.
Vibration resistance (Functional) 10 to 55Hz double amplitude of 1.5mm X, Y, Z axes
Shock resistance (Functional) Min. 980 m/s2X, Y, Z axes
Ambient temperature –20°C to +80°C –4°F to +176°F*2Non-condensing at low
temperatures
Storage temperature –25°C to +85°C –13°F to +185°F
Operational method Zero-cross (Turn-ON and Turn-OFF)
Type 10A 15A 20A 25A 40A Remarks
Part No.
AQN121
AQN121L
AQN121V
AQN121VL
AQN221
AQN221L
AQN221V
AQN221VL
AQN321
AQN321L
AQN321V
AQN321VL
AQN421
AQN421L
AQN421V
AQN421VL
AQN621
AQN621L
AQN621V
AQN621VL
Operate time, max. 1ms
Release time, max. 1/2 cycle of voltage sine wave + 1ms
Insulation resistance, min. 100M between input and output at 500 V DC
Breakdown voltage 4,000 Vrms between input and output; 2,500 Vrms between input, output and case for 1min.
Vibration resistance (Functional) 10 to 55Hz double amplitude of 1.5mm X, Y, Z axes
Shock resistance (Functional) Min. 980 m/s2X, Y, Z axes
Ambient temperature –20°C to +80°C –4°F to +176°FNon-condensing at low
temperatures
Storage temperature –25°C to +85°C –13°F to +185°F
Operational method Random Turn-ON, Zero-cross Turn-OFF
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AQ-N
REFERENCE DATA
1. Load current vs. ambient temperature
Use load current within range specified in the figure below.
Tested condition
With external heat sink
1) (1) 10A, 15A, 20A type
Shown with standard heat sink
(AQP801)
(2) Shown with 25A type standard heat sink
(AQP804)
(3) Shown with 40A type standard heat sink
(AQP806)
(4) In the case of the AQP812 slim heat-sink
types, characteristics data are available
for each type. Please refer to (6).
2) If attached to a heat sink, use a heat
conductive compound (Ex. Toshiba silicone
YG6111 or TSK5303) of similar coating to
improve cooling.
Without external heat sink
If the mounting surface is not metallic and a
heat sink is not used, expose the bottom
surface and plate surface to improve heat
dissipation.
(1) 10A type
4
2
6
8
10
12
00-20 20 40 60 80 100
Ambient temperature, °C
Load current, A
When using AQP-HS-J10A or a steel
plate of 100×100×t0.8 (mm) or greater
When using as
stand-alone
(2) 15A type (3) 20A type (4) 25A type
10080604020-20 0
5
10
15
20
0
Ambient temperature, °C
Load current, A
When using a steel
plate of 100×100×t1.6
(mm) or greater
When using as stand-alone
When using AQP-HS-J10A or a steel plate
of 150×150×t1.6 (mm) or greater
Ambient temperature, °C
Load current, A
10080604020-20 0
5
10
15
20
25
0
When using as stand-alone
When using a steel plate
of 75×75×t1.6 (mm) or greater
When using AQP-HS-J10A
When using a steel
plate of 100×100×t1.6
(mm) or greater
When using a steel
plate of 150×150×t1.6
(mm) or greater
10080604020-20 0
5
10
15
20
25
30
0
When using a steel
plate of 150×150×t1.6
(mm) or greater
When using a steel
plate of 100×100×t1.6
(mm) or greater
When using as stand-alone
When using
AQP-HS-30/40A
When using
AQP-HS-J10A
Ambient temperature, °C
Load current, A
(5) 40A type (6) Data when mounted on an AQP-HS-SJ20A
slim heat sink
2. Non-repetitive surge current vs. carrying
time
10080604020-20 0
5
10
15
20
25
30
35
40
45
0
When using a steel plate
of 150×150×t1.6 (mm)
or greater
When using a steel plate of
100×100×t1.6 (mm) or greater
When using a steel plate of
75×75×t1.6 (mm) or greater
When using as stand-alone
When using
AQP-HS-J25A
When using
AQP-HS-30/40A
Ambient temperature, °C
Load current, A
0
5
30
15
20
25
10
02040 1008060
40 A type
25 A type
20 A type
15 A type
10 A type
Ambient temperature, °C
Load current, A
0
100
500
400
300
200
110100
No. of cycles at 60 Hz
Non-repetitive surge current, A
10 A type
15A type
20A type 25A type
40A type
3. Input current vs. input voltage
10A, 15A, 20A, 25A, 40A common
2
6
4
8
12
10
14
16
10 155020253530
Input voltage, V
Input current, mA
Without LED
With LED
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AQ-N
DIMENSIONS (mm inch)
ACCESSORIES
The CAD data of the products with a CAD Data mark can be downloaded from: http://panasonic-electric-works.net/ac
* The right figure is the
LED indication type.
The standard type has
the same dimensions.
External dimensions
58.0
4.5 dia.
.177 dia.
47.5
43.2
22.0
20.0
27.0 max.
4.5
25.445.0 11.4 27.9
2.283
1.870
1.701
2-M3 2-M4
.866
.787
1.063 max.
.177
1.0001.772 .449 1.098
Schematic
Mounting dimensions
Load power
source
1
2
4
3
Input power
source
+
_Load
1.870 +.008
.004
47.5 +0.2
0.1
2-.069 dia. or M4
2-4.3 dia. or M4
CAD Data
AQP-HS-SJ20A Slim Heat Sink
AQP812
4.6×5.6 elliptical hole
.181×.220
.181 dia.
4.6 dia.
5-M4
(Effective screw depth: 6mm .236inch)
47.6 1.874
40
100
45
1.772
90
78
1.575
3.937
3.543
3.071
30
1.181
30
1.181
70707
“A” part
.063
1.6
6
.236
78
3.071 83
3.268
Mounting dimensions
2-.181 dia. or M4
2-4.6 dia. or M4
90±0.2
3.543±.008
6
.236
General tolerance: ±1.0 ±.039
Note:
When using on a DIN rail, please install so that the “A” part is on top.
CAD Data
AQP-HS-J10A Standard Heat Sink
1.5
2
2
11.1
1.5
4.4
.173
.059
.079
.079
.437
.059
3-M4
R2.2
.087
4.4
.173
90
3.543
100
3.937
47.6
1.874
30
1.181
50
1.969
33.3
1.311
54
2.126
80
3.150
100+0.5
1.5
+.020
.059
3.937
45
1.772
28.5
1.122
24.5
.965
9
.354
Mounting dimensions
4-M4 or 4.4 dia.
50±0.2
90±0.1
4-M4 or .173 dia.
1.969±.008
3.543±.004
CAD Data
AQP-HS-30/40A Standard Heat Sink
90
4.4 4.4
50
54 100+0.5
1.5
3.937+.020
.059
80
33.3
47.6
56
150 24.5
1.5
2
2
11.1
1.5
28.5
45
9
R 2.2 .087
3-M4
3.543
.173 .173
1.969
2.126
3.150
1.311
1.874
2.205
5.906 .965
.059
.079
.079
.437
.059
1.122
1.772
.354
General tolerance: ±0.5 ±.020
Mounting dimensions
4-M4 or 4.4 dia.
50±0.2
90±0.1
4-M4 or .173 dia.
1.969±.008
3.543±.004
CAD Data
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AQ-N
AQP-HS-J25A Standard Heat Sink
120
.079
2
100
82
64
46
7
.276
3-M4
132
5.197
142
4.724
3.937
3.228
2.520
1.811
5.591
13
.512
5
.197
30
1.181
52
2.047
3
.118
150
5.906
119
4.685
47.5
1.870
4-R2.5
4-R.098
Mounting dimensions
4-M4.5 or .197 dia.
4-M4.5 or 5 dia.
132±0.1
5.197±.004
119±0.1
4.685±.004
CAD Data
AQP-DP DIN Rail Mounting Plate
General tolerance: ±0.5 ±.020
86
44
18.1
M4
70
56
47.6
13.6
M4
M4
3.386
1.732
.713
2.765
2.205
1.874
.535
AT8-DLA1 Mounting Rail
15
5 5
10
1,000
5.5
35
1.5
27
24
15
40-5.5×15 slot
15 10 15
7.5
2.75R
.591
.197 .394
39.37
.217
1.378
.059
1.063
.945
.591 .591 .394 .591.108R
40-.217×.591 slot
.197
.295
CAD Data CAD Data
ATA4806 Fastening Plate
12
50
M4
10
10
ATA4806
UP
.472
1.969
.394
.394
AQP-NPC Terminal Cover
4-7 dia.
44.6
10
27.9
43.2
25.4 2
57.5
24
1.5
4-.276 dia.
1.756
.394
1.098
1.701
1.000 .079
2.264
.945
.059
CAD Data CAD Data
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
AQ-N
Recommended Temperature Controllers
For Cautions for Use
48mm
56mm
1.890inch
2.205inch
48mm
1.890inch
<KT4H Temperature Controller>
Our temperature controller is recommended for use with our Solid State Relays.
Features
• Data can be collected using the RS485 communications interface via a PLC.
• Improved visibility using a negative type LCD and backlight.
• Depth-wise length (chassis dimension) is 56 mm 2.205 inch.
Substitute part numbers
*For detailed product information about temperature controllers, please refer to our website:
http://panasonic-denko.co.jp/ac/e/fasys/component/temperature_controller/
Power supply Control output Part No.
100 to 240 V AC Relay contact AKT4H111100
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Panasonic:
AQP-HS-30/40A AQP-HS-J25A