E5_C General purpose temperature controllers
12
Specifications
E5CC/E5EC/E5AC
Item E5CC E5EC E5AC
Power supply voltage A in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range 85% to 110% of rated supply voltage
Power consumption 6.5 VA max. at 100 to 240 VAC, and
4.1 VA max. at 24 VAC or
2.3 W max. at 24 VDC
8.3 VA max. at 100 to 240 VAC, and
5.5 VA max. at 24 VAC or
3.2 W max. at 24 VDC
9.0 VA max. at 100 to 240 VAC, and
5.6 VA max. at 24 VAC or
3.4 W max. at 24 VDC
Sensor input • Temperature inputs
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
• Analog inputs
Current input (mA): 4 to 20 or 0 to 20
Voltage input (V): 1 to 5, 0 to 5, or 0 to 10
Input impedance Current input: 150 max., Voltage input: 1 M min.
(Use a 1:1 connection when connecting the ES2-HB/THB.)
Control method ON/OFF control or 2-PID control (with auto-tuning)
Indication accuracy Thermocouple input: (±0.3% of indicated
value or ±1°C, whichever is greater)
±1 digit max.
Platinum resistance thermometer input:
(±0.2% of indicated value or ±0.8°C,
whichever is greater) ±1 digit max.
Analog input: ±0.2% FS ±1 digit max.
CT input: ±5% FS ±1 digit max.
Thermocouple input: (±0.3% of indicated value or ±1°C, whichever is greater)
±1 digit max.
Platinum resistance thermometer input: (±0.2% of indicated value or ±0.8°C, which-
ever is greater) ±1 digit max.
Analog input: ±0.2% FS ±1 digit max.
CT input: ±5% FS ±1 digit max.
Potentiometer input: ±5% FS ±1 digit max.
Auto-Tuning Yes, 40%/100% MV output limit selection. When using Heat/Cool: Automatic cool gain adjustment
Self-Tuning Yes
Control outputs Relay output SPST-NO, 250 VAC, 3 A (resistive load),
electrical life: 100,000 operations,
minimum applicable load: 5 V, 10 mA
SPST-NO, 250 VAC, 5 A (resistive load),
electrical life: 100,000 operations,
minimum applicable load: 5 V, 10 mA
Voltage output (for driving SSR) Output voltage: 12 VDC ±20% (PNP), max.
load current: 21 mA, with short-circuit
protection circuit
Output voltage: 12 VDC ±20% (PNP),
max. load current: 40 mA, with short-circuit protection circuit
(The maximum load current is 21 mA for models with two control outputs.)
Linear current output 4 to 20 mA DC/0 to 20 mA DC, load: 500 max., resolution: approx. 10,000
Auxiliary outputs Number of outputs 2,3 4
Output specifications N.O. relay outputs, 250 VAC,
Models with 3 outputs: 2 A (resistive
load), electrical life: 100,000 operations,
minimum applicable load: 5 V, 10 mA
N.O. relay outputs, 250 VAC,
Models with 4 outputs: 2 A (resistive load),
electrical life: 100,000 operations,
minimum applicable load: 5 V, 10 mA
Event inputs Number of inputs 2 or 4 or 6 max (depends on the model)
External contact input specifications Contact input: ON: 1 k max., OFF: 100 k min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: approx. 7 mA per contact
Setting method Digital setting using front panel keys or via Remote Software CX-Thermo V4.5
Indication method 11-segment digital display and individual indicators
Multi SP Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key operations, or serial communications.
Other functions Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout detection (includ-
ing SSR failure detection), 40% AT, 100% AT, MV limiter, input digital filter, self-tuning, temperature input shift, run/stop, pro-
tection functions, extraction of square root, MV change rate limit, logic operations, PV/SV status display, simple program,
automatic cooling coefficient adjustment
Ambient operating temperature –10 to 55°C (with no condensation or icing)
Ambient operating humidity 25% to 85%
Storage temperature –25 to 65°C (with no condensation or icing)
Degree of protection Front panel: IP66, Rear case: IP20, Terminals: IP00
Sampling period 50 ms
Size in mm (H×W×D) 48×48×64 48×96×64 96×96×64
E5_C+tecPart+brochure_03_2016.fm Seite 12 Donnerstag, 17. März 2016 10:23 10
E5_C General purpose temperature controllers
13
E5GC
E5DC
Item E5GC
Power supply voltage A in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Sensor input • Temperature input
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
• Analog input
Current input: 4 to 20 mA or 0 to 20 mA
Voltage input: 1 to 5 V, 0 to 5 V, or 0 to 10 V
Control method ON/OFF control or 2-PID control (with auto-tuning)
Control output Relay output SPST-NO, 250 VAC, 2 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA (reference value)
Voltage output (for driving SSR) Output voltage 12 VDC ±20% (PNP), max. Load current: 21 mA, with short-circuit protection circuit
Linear current output 4 to 20 mA DC/0 to 20 mA DC, load: 500 Ω max., resolution: Approx. 10,000
Auxiliary output Number of outputs 1 or 2 (depends on model)
Output specifications SPST-NO relay outputs, 250 VAC, 2 A (resistive load),
Electrical life: 100,000 operations, Minimum applicable load: 10 mA at 5 V (reference value)
Indication method 11-segment digital displays and individual indicators
Character height: PV: 10.5 mm, SV: 5.0 mm
Multi SP Up to eight set points (SP0 to SP7) can be saved and selected using the event inputs, key operations, or serial communications.*1
*1 Only four set points are selectable for event inputs.
Other functions Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout (HB) alarm (includ-
ing SSR failure (HS) alarm), 40% AT, 100% AT, MV limiter, input digital filter, self tuning, robust tuning, PV input shift, run/stop,
protection functions, extraction of square root, MV change rate limit, logic operations, temperature status display, simple pro-
gramming, moving average of input value, display brightness setting, simple transfer output, and work bit message.*2
*2 Simple transfer output and work bit message are only for E5GC.
Size in mm (H×W×D) 24×48×93
Item E5DC
Power supply voltage A in model number: 100 to 240 VAC, 50/60 Hz
D in model number: 24 VAC, 50/60 Hz; 24 VDC
Operating voltage range 85% to 110% of rated supply voltage
Power consumption 4.9 VA max. at 100 to 240 VAC, and
2.8 VA max. at 24 VDC or
1.5 W max. at 24 VDC
Sensor input • Temperature inputs
Thermocouple: K, J, T, E, L, U, N, R, S, B, W, or PL II
Platinum resistance thermometer: Pt100 or JPt100
Infrared temperature sensor (ES1B): 10 to 70°C, 60 to 120°C, 115 to 165°C, or 140 to 260°C
• Analog inputs
Current input (mA): 4 to 20 or 0 to 20
Voltage input (V): 1 to 5, 0 to 5, or 0 to 10
Input impedance Current input: 150 max., Voltage input: 1 M min. (Use a 1:1 connection when connecting the ES2-HB/THB.)
Control method ON/OFF control or 2-PID control (with auto-tuning)
Indication accuracy Thermocouple input: (±0.3% of PV or ±1°C, whichever is greater) ±1 digit max.
Platinum resistance thermometer input: (±0.2% of PV or ±0.8°C, whichever is greater) ±1 digit max.
Analog input: ±0.2% FS ±1 digit max.
CT input: ±5% FS ±1 digit max.
Auto-Tuning Yes, 40%/100% MV output limit selection. When using Heat/Cool: Automatic cool gain adjustment
Self-Tuning Yes
Control outputs Relay output SPST-NO, 250 VAC, 3 A (resistive load), electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA
Voltage output (for driving SSR) Output voltage: 12 VDC ±20% (PNP), max. load current: 20 mA, with short-circuit protection circuit
Linear current output 4 to 20 mA DC/0 to 20 mA DC, load: 500 max., resolution: approx. 10,000
Auxiliary outputs Number of outputs 2 (depends on model)
Output specifications SPST-NO relay outputs: 250 VAC, 2 A (resistive load),
Electrical life: 100,000 operations, minimum applicable load: 5 V, 10 mA
Event inputs Number of inputs 1 (depends on model)
External contact input specifications Contact input: ON: 1 k max., OFF: 100 k min.
Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max.
Current flow: approx. 7 mA per contact
Setting method Digital setting using front panel keys
Indication method 11-segment digital displays and individual indicators
Character height: PV 8.5 mm, SV: 8.0 mm
Multi SP Up to eight set points (SP0 to SP7) can be saved and selected using event inputs, key operations, or serial communications.*1
*1 Only two set points are selectable for event inputs.
Other functions Manual output, heating/cooling control, loop burnout alarm, SP ramp, other alarm functions, heater burnout (HB) alarm (includ-
ing SSR failure (HB) alarm), 40% AT, 100% AT, MV limiter, input digital filter, self tuning, robust tuning, PV input shift, run/stop,
protection functions, extraction of square root, MV change rate limit, simple calculations, temperature status display, simple pro-
gramming, moving average of input value, and display brightness setting
Ambient operating temperature –10 to 55°C (with no condensation or icing), for 3-year warranty: –10 to 50°C (with no condensation or icing)
Ambient operating humidity 25% to 85%
Storage temperature –25 to 65°C (with no condensation or icing)
Degree of protection Main unit: IP20, Terminal unit: IP00
Sampling period 50 ms
Size in mm (H×W×D) 96×22.5×85