Environmental Specifications
Temperature Range:
-55°C to +85°C or -55°C to +125°C.
Vibration: 20 G’s, 10 - 2,000 Hz.
Shock: 50 G’s, 11 ± 1ms duration.
Insulation Resistance: 1,000
megohms, min., at 500Vdc.
Dielectric Strength: 1,000Vrms, 60
Hz., at sea level, all terminals to case.
Sealing: Hermetic, 1.3 in. (33.0mm) of
mercury.
Life: 100,000 operations, min. (2A and
5A models); 50,000 operations, min.
(10A models);
Weight: 8.5 oz (240g) max.
1
Catalog 8-1773439-1 Dimensions are in inches and Dimensions are shown for USA: 1-800-522-6752 South America: 55-11-3611-1514
Revised 4-05 millimeters unless otherwise reference purposes only. Canada: 1-905-470-4425 Hong Kong: 852-2735-1628
specified. Values in brackets Specifications subject Mexico: 01-800-733-8926 Japan: 81-44-844-8013
www.tycoelectronics.com are metric equivalents. to change. C. America: 52-55-5-729-0425 UK: 44-141-810-8967
© 2005 by Tyco Electronics Corporation. All Rights Reserved.
CII and TYCO are trademarks.
Other products and company names mentioned herein may be trademarks of their respective owners.
Product Facts
DC input delay on release
timer offered in fixed (5600)
and adjustable (5700) types
Up to 10A loads
Reverse polarity protection
CMOS digital design
Built to MIL-R-83726
environmentals
Many customizing options
Extended timing ranges
Tighter timing tolerances
Header and mounting
Different Aux. voltages
Different control line
voltages
Input either 115Vac, 60 Hz.
or 400 Hz.
5600/5700 Series Delay On Release Timers
Fixed/Adjustable Timing, Relay Output
CII 5600/6700 series delay on
release timers combine solid
state timing circuits with
electromechanical output
relays in robust hermetically
sealed enclosures. The 5600
types are fixed timers, while the
5700 models are adjustable via
an external resistor. Numerous
output options include 2A, 5A
and 10A rated contacts in 1,
and 2 form C (SPDT and DPDT)
arrangements.
Electrical Specifications
Timing Range:
5600 series (fixed): 50 ms to 600 s.
5700 series (adjustable): 50 ms to
240 s.
Tolerance: ±10% or ±15ms, whichever
is less
Recycle Time: 10 ms .
Reset Time: 20 ms .
Operate Time (Max.) : 10 ms (2A
and 5A models), 20ms (10A models).
Input Voltage: 18 to 31Vdc.
Control Voltage: 10 to 31Vdc. Ground
common to aux. power line. 10Vdc
minimum must be applied for a
minimum duration of 20ms to energize
output and initiate the timing circuit.
Current Drain (at 25°C, 28Vdc):
Control Line: 15mA typ., 25mA max.
Input Line De-energized (after
completion of delay period): 125
mA.
Input Line Energized:
1-pole, 2 & 5A models: 100mA.
1-pole, 10A models: 150mA.
2-pole, 2 & 5A models: 150mA.
2-pole,10A models: 240mA.
Contact Ratings:
10A contacts:
10A resistive @ 30Vdc.
5A inductive @ 30Vdc.
5A resistive @ 115 Vrms, 400 Hz
3A inductive @ 115 Vrms, 400 Hz
5A contacts:
5A resistive @ 30Vdc.
1.5A inductive @ 30Vdc.
3A resistive @ 115 Vrms, 400 Hz
1A inductive @ 115 Vrms, 400 Hz
2A contacts:
2A resistive @ 30Vdc.
1A inductive @ 30Vdc.
1A resistive @ 115 Vrms, 400 Hz
0.3A inductive @ 115 Vrms, 400 Hz
Adjustable Timing Formula
(4700 types)
The resistance required to obtain timing
within this range is determined by using
the formula:
Rx = 400K (T/Tmax.) – 40K, where
Rx = External Resistance in Ohms,
T - Desired Time in Seconds, and
Tmax. = Maximum Time (Code).
A high quality deposited carbon ±1%,
0.1W (min.) resistor is recommended for
external resistance.
Timing Diagram
Apply input power. Upon application of
control power, the output will energize.
Remove control power and initiate delay
period.
ON
OFF
INPUT
ON
OFF
OUTPUT
ON
OFF
CONTROL
<--- DELAY --- >
Specifications by Model Number
Fixed Timer Adjustable Timer Input Temperature Contact Contact Available
Model Number Model Number Voltage Range Rating Arrangement Enclosures
5601 5701 DC -55°C to +85°C 2 Amp 1 Form C (SPDT) A - C - D - E
5602 5702 DC -55°C to +85°C 2 Amp 2 Form C (DPDT) A - C - D - E
5605 5705 DC -55°C to +85°C 5 Amp 1 Form C (SPDT) D - E
5606 5706 DC -55°C to +85°C 5 Amp 2 Form C (DPDT) D - E
5610 5710 DC -55°C to +85°C 10 Amp 1 Form C (SPDT) D - E
5611 5711 DC -55°C to +85°C 10 Amp 2 Form C (DPDT) D - E
5621 5721 DC -55°C to +125°C 2 Amp 1 Form C (SPDT) A - C - D - E
5622 5722 DC -55°C to +125°C 2 Amp 2 Form C (DPDT) A - C - D - E
5625 5725 DC -55°C to +125°C 5 Amp 1 Form C (SPDT) D - E
5626 5726 DC -55°C to +125°C 5 Amp 2 Form C (DPDT) D - E
See next page for complete ordering information and outline dimensions for the available enclosures.
Special Notes
10Vdc mimimum must be applied for a
minimum duration of 20ms to energize
output and initiate timing.
Units rated 10A have a minimum time
delay of 100ms.
2
5600/5700 Series Delay On Release Timers (Continued)
High Performance Electronic Products
Catalog 8-1773439-1 Dimensions are in inches and Dimensions are shown for USA: 1-800-522-6752 South America: 55-11-3611-1514
Revised 4-05 millimeters unless otherwise reference purposes only. Canada: 1-905-470-4425 Hong Kong: 852-2735-1628
specified. Values in brackets Specifications subject Mexico: 01-800-733-8926 Japan: 81-44-844-8013
www.tycoelectronics.com are metric equivalents. to change. C. America: 52-55-5-729-0425 UK: 44-141-810-8967
2.50 MAX.
[63.5]
.281 MAX.
[7.14]
.375
[9.53]
#4-40 UNC-2A
4 PLACES
INDEX DOT
.81 DIA.
[20.57]
MAX.
.875
[22.22]
1.25 MAX.
[31.75]
1.0 MAX.
[25.4]
.625
[15.875]
1.812
[
46.02]
.063 MAX.
[1.60]
.531
[13.49]
INDEX DOT
1.542
[39.17]
1.542
[39.17]
.875
[22.22]
2.09
[53.09]
2.491 MAX.
[63.27]
Outline Dimensions
Mounting Option A Mounting Option D Mounting Option E
TIMING
RESISTOR
AUX.
INPUT
+
AUX.
INPUT
+
TIMING
RESISTOR
CONTROL +
+
CONTROL
5700 Series
(Adjustable)
Wiring Diagrams
AUX.
INPUT
+
AUX.
INPUT
+
CONTROL + CONTROL +
5600 Series
(Fixed)
1 Form C 2 Form C 1 Form C 2 Form C
.063 MAX.
[1.60]
.380 TYP.
[9.53]
#4-40 UNC-2
A
4 PLACES
INDEX
DOT
.625
[15.875]
.305
[7.747]
1.25 MAX.
[31.75]
1.0 MAX.
[25.4]
.625
[15.875]
.469 MAX.
[11.91]
1.25
[31.75]
.810 DIA.
[20.57]
MAX.
2.50 MAX.
[63.5]
.547
[13.89]
Mounting Option C
1.812 MAX.
[46.02]
.063 MAX.
[1.60]
.375
[9.53]
#6-32 UNC-2A
4 PLACES
INDEX DOT
1.187
[30.15]
1.542
[39.17]
1.542
[39.17] 1.187
[30.15]
.281 MAX.
[9.53]
Part Numbering System
Typical Part Number 5722 –C – 1102
Model Number:
Four digit code from table on the previous page.
Mounting (see outline dimension drawings):
A = Studs on bottom of 2.5 in tall case C = Studs on side of 2.5 in. tall case
D = Studs on bottom of 1.812 in. tall case E = Bracket on side of 1.812 in. tall case
Timing Code:
Four-digit code for any value between 50ms and 600s for fixed (5600) timers and between 50ms and 240s for adjustable (5700) timers.
The timing code consists of four digits and gives the time in ms. The first three digits are the significant figures and the last digit is the number of zeros following the significant
figures; thus 50 ms would be coded 0500, 1.1 s would read 1101, and 1 m (60 s) would be 6002.
Adjustable timers cover one decade, e.g., 62 ms to 620 ms. The upper decade limit is Tmax. in the timing formula and is the the value defined by the timing code in the part
number.
Note: Units with 10A contacts have a minimum time delay of 100ms.
A typical part number for an adjustable timer would be 5722–C–1102. This DC unit is in the -55°C to +125°C temperature range with a 2 amp contacts in a 2 form C (DPDT)
arrangement, enclosed in case with a style “C” mounting, with a maximum time delay of 11s.