SPECIFICATION CONTROL DRAWING Product Revisions Part Names B-058-00 J B-058-01 G B-058-02 H L max 16.5 (0.650) 16.5 (0.650) 22.1 (0.870) Product Dimensions A B min min 2.6 3.1 (0.100) (0.120) 4.4 4.9 (0.175) (0.195) 6.9 7.4 (0.270) (0.290) K min 150 (5.900) 150 (5.900) 150 (5.900) Cable Dimensions E F min min 1.6 1.5 (0.630) (0.060) 2.2 2.1 (0.085) (0.080) 3.4 3.2 (0.135) (0.125) D max 2.6 (0.100) 4.4 (0.175) 6.9 (0.270) J1 (J0.04) 7 (0.275) 7 (0.275) 7 (0.275) MATERIAL 1. INSULATION SLEEVE: Heat-shrinkable, radiation cross-linked modified polyvinylidene fluoride. Transparent blue. 2. SOLDER PREFORM WITH FLUX: SOLDER: TYPE Sn63 per ANSI J-STD-006. FLUX: TYPE ROL1 per ANSI J-STD-004. 3. & 4. MELTABLE RINGS: Thermally stabilized thermoplastic. Color: clear. 5. GROUND LEAD: RAYCHEM 55A0111-24 in accordance with MIL-W-22759/32 24 AWG. Stranded tin plated copper. Color: blue. APPLICATION 1. These parts are designed to provide an environment protected shield termination on cables rated for 125C minimum, meeting the dimensional criteria listed and having tin or silver plated shields. 2. Temperature range: -55C to +150C. 3. Install using Raychem-approved convection or infrared heating tools in accordance with Raychem installation procedure RPIP-709-00. For best results, prepare the cable as shown: *A trademark of Raychem Corporation. THERMOFIT DEVICES Raychem Corporation 300 Constitution Drive Menlo Park, CA 94025 USA UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETERS. INCHES DIMENSIONS ARE IN BETWEEN BRACKETS. Raychem reserves the right to amend this ANGLES: N/A TOLERANCES: drawing at any time. Users should 0.00 N/A evaluate the suitability of the product for ROUGHNESS IN 0.0 N/A their application. MICRON 0 N/A TITLE: SOLDERSLEEVE* DEVICE WITH PRE-INSTALLED LEAD .: B-058-0X DOCUMENT NO DCR NUMBER: REPLACES: D981675 DRAWN BY: DATE: REV.: DOC ISSUE: R. MAPALO 16-Oct-98 SEE TABLE 4 If this document is printed it becomes uncontrolled. Check for the latest revision. SCALE: NONE B0580X SIZE: A SHEET: 1 of 1