Monitoring Relays 3-Phase Load Guard Types DWB01, PWB01 DWB01 * TRMS load guard relays for three phase balanced applications * Measuring if the power factor is within set limits * Measure voltage on own power supply * Measuring ranges: 5A, 10A, MI current transformers * Power ON delay 1 to 30 s knob adjustable * Separately adjustable upper/lower level on absolute scale * Programmable latching or inhibit at set level * Automatic and manual start and stop of the system * Output: 8 A SPDT relay N.D. or N.E. selectable * For mounting on DIN-rail in accordance with DIN/EN 50 022 (DWB01) or plug-in module (PWB01) * 45 mm Euronorm housing (DWB01) or 36 mm plug-in module (PWB01) * LED indication for relay, alarm and power supply ON PWB01 Product Description Ordering key DWB01 and PWB01 are precise TRMS power factor monitoring relays for 3phase balanced systems. They can be used for monitoring the actual load of asynchronous motors and other symmetrical loads, where the power factor is almost proportional to the load. The relay measures the power factor (cos ), that is the ratio between the active and the apparent power of a motor. Housing Function Type Item number Output Power Supply Range Start/stop input allows to use a manual switch to start and stop the motor, without the need of an auxiliary device. The advantage of using the latch function is that the relay can be kept energized even after the end of the alarm condition. Inhibit function can be used to avoid relay operation when not desired (maintenance, transients). The LED's indicate the state of the alarm and the output relay. DWB 01 C M48 10A Type Selection Mounting Output Supply: 208 to 240 VAC Supply: 380 to 415 VAC DIN-rail Plug-in SPDT SPDT DWB 01 C M23 10A PWB 01 C M23 10A PWB 01 C M48 10A Supply: 380 to 480 VAC Supply: 600 to 690 VAC DWB 01 C M48 10A DWB01 C M69 10A Input Specifications Input Voltage (Own power supply): 3 - phase 1- phase Current: Measuring ranges Power factor (cos ) DWB01: PWB01: M23: DWB01CM48: PWB01CM48: DWB01CM69: L1, L2, L3 5, 6, 7 208 to 240 VAC 15% 380 to 480 VAC 15% 380 to 415 VAC 15% 600 to 690 VAC 15% DWB01CM23: PWB01CM23: L1, L2 (connect pins L2, L3) 5, 6 (connect pins 6, 7) 208 to 240 VAC 15% DWB01: PWB01: 5A, 10A: MI...: 5A, 10A: MI...: I1, I2 U1, U2 11, 10 9, 8 Specifications are subject to change without notice (09.12.05) Direct input: Upper level 0.1 to 0.99 AACrms Lower level 0.1 to 0.99 Max. curr. (30 s) 0.5 to 5A 1 to 10A 30A 50A Standard CT (examples) TADK2 50 A/5 A TAD2 150 A/5 A TAD6 400 A/5 A TAD12 1000 A/5 A TACO200 6000 A/5 A 5 to 50 A 15 to 150 A 40 to 400 A 100 to 1000 A 600 to 6000 A 60 A 180 A 480 A 1200 A 7200 A MI CT ranges MI 100 MI 500 10 to 100 A 50 to 500 A 325 AAC 1000 AAC 1 DWB01, PWB01 Input Specifications (cont.) Output Specifications Note: The input voltage cannot raise over 300 VAC with respect to ground (PWB01 only) Contact input DWB01 PWB01 Disabled Enabled Pulse width Hysteresis Output Rated insulation voltage Contact ratings (AgSnO2) Resistive loads AC 1 DC 12 Small inductive loads AC 15 DC 13 Mechanical life Electrical life Terminals Z1, U1 Terminals 2, 9 > 10 k < 500 > 500 ms PF approx 0.1 SPDT relay 250 VAC 8 A @ 250 VAC 5 A @ 24 VDC 2.5 A @ 250 VAC 2.5 A @ 24 VDC 30 x 106 operations 105 operations (at 8 A, 250 V, cos = 1) Operating frequency 7200 operations/h Dielectric strength According to EN 60947-1 Dielectric voltage 2 kVAC (RMS) Rated impulse withstand volt. 4 kV (1.2/50 s) General Specifications Supply Specifications Power ON delay Reaction time 1 to 30 s 0.5 s (input signal variation from -20% to +20% or from +20% to -20% of set value) < 200 ms < 200 ms (15 min warm-up time) 1000 ppm/C 10% on set value 50 ms 0.5% on full-scale Power supply Rated operational voltage Through terminals: DWB01: PWB01: M23 DWB01CM48 PWB01CM48 DWB01CM69 Dielectric voltage LED, green LED, red (flashing 2 Hz during delay time) LED, yellow Dielectric voltage supply to output Rated operational power M23: M48: M69: Supplied by Alarm ON delay Alarm OFF delay Accuracy Temperature drift Delay ON alarm Repeatability Indication for Power supply ON Alarm ON Output relay ON Environment Degree of protection Pollution degree Operating temperature @ Max. voltage, 50 Hz @ Max. voltage, 60 Hz Storage temperature Housing dimensions DIN-rail version Plug-in version Weight Screw terminals Tightening torque Approvals CE-Marking EMC Immunity Emissions 2 IP 20 3 (DWB01), 2 (PWB01) -20 to 60C, R.H. < 95% -20 to 50C, R.H. < 95% -30 to 80C, R.H. < 95% 45 x 80 x 99.5 mm 36 x 80 x 94 mm Approx. 250 g Max. 0.5 Nm acc. to IEC 60947 UL, CSA Yes Electromagnetic Compatibility According to EN 61000-6-2 According to EN 61000-6-3 Overvoltage cat. III (IEC 60664, IEC 60038) L1, L2, L3 5, 6, 7 177 to 276 VAC 45 to 65 Hz 323 to 552 VAC45 to 65 Hz 323 to 477 VAC 45 to 65 Hz 510 to 793 VAC 45 to 65 Hz None 4 kV 9 VA @ 230 VAC, 50 Hz 13 VA @ 400 VAC, 50 Hz 21 VA @ 600 VAC, 50 Hz L1 and L2 Mode of Operation DWB01 and PWB01 can be used for monitoring the actual load of asynchronous motors. The relay measures the absolute value for the power factor of the system PF= Active Power/Apparent Power that is for balanced system with sinus waveforms the cosine of the angle between motor current and motor voltage (cos ). As cos varies with the load of the motor, underload and overload can be indirectly detected by DWB01 and PWB01. The relation between the load and cos depends on the type of motor. As a guideline to ensure correct working conditions for a motor, the upper level could be set above the cos marking on the motor, and the lower level under this value. It is anyway recommended to make the adjustment in connection with a practical test. The relay has an adjustable power ON delay in order to avoid overload detection during motor start. Example 1 Latching mode, relay NE In this application DWB01 or PWB01 are connected to an external current metering transformer, type MI..., (connected between U1 & U2) as Specifications are subject to change without notice (09.12.05) DWB01, PWB01 Mode of Operation (cont.) well as to a 3-phase asynchronous motor. The relay energizes as soon as the power supply is applied. After the power ON delay, the unit starts measuring cos . If cos is within the setpoints the relay is energized. As soon as the power factor drops below the lower setpoint or exceeds the upper setpoint the output relay releases and the red LED turns on after the set time has expired. To restart the cos measurement, connect Z1 and U1 (2 and 9) or interrupt the power supply for at least 1 s. automatic reactivation of the relay as soon as cos is back within the two setpoints. When the measured cos exceeds the set upper level, the red LED starts flashing. The output relay releases after the set time period. When the measured cos drops below the set lower level, the red LED starts flashing, and the output relay releases after the set time period. When the output relay releases there will be no LED indication. Example 3 1-Phase load monitoring DWB01CM2310A and PWB01CM2310A can be used for monitoring the power factor of a 1-Phase load with 208 to 240 V AC mains voltage. In this case the pow- Example 2 Non-latching mode, relay NE DWB01 and PWB01 react as described in the previous example 1 except for the er supply has to be connected between L1, L2 (or 5, 6), L2 and L3 (or 6 and 7) have to be connected. Example 4 Start/stop mode, relay NE In this application DWB01 or PWB01 are directly connected to a 3-phase asynchronous motor. The relay energizes as soon as the power supply is applied and the start/stop contact is closed. After the power ON delay, the unit starts measuring cos . If cos is within the setpoints the relay energizes. As soon as the power factor drops below the lower setpoint or exceeds the upper setpoint the output relay releases and the red LED turns ON after the set time has expired. When the start/stop contact is opened the relay de-energizes immediately. To restart the system just connect the start/stop contact. Note 1: to use the start/stop function the output relay has to command a contactor connected in series to the load (see last two wiring diagrams). Note 2: in case of current below the minimum level the alarm is conventionally ON. Note 3: (3-phase voltage): connect the 3-phase power supply to the terminals L1, L2 and L3 (DWB01) - 5, 6 and 7 (PWB01) taking care of the sequence. Function/Range/Level/Time Setting Select the desired function setting the DIP-switches 1 to 4 as shown on the right. To access the DIP-switches open the plastic cover using a screwdriver as shown on the right. If DIP switch 3 is set to ON (start/stop) the position of DIP-switch 4 does not affect the products working mode. Lower left knob: Setting of delay on absolute scale: 0.1 to 30 s. Input current range (terminals I1, I2 or 10, 11) ON: 10A OFF: 5A/MI input Lower right knob: Setting of power ON delay on absolute scale: 1 to 30 s. Relay status ON: Relay de-energized in normal condition OFF: Relay energized in normal condition Working mode ON: Contact input for start/stop functions OFF: Contact input for latch/inhibit functions Contact input (SW4 does not affect the working mode if SW3 is ON) ON: Latch function enable OFF: Inhibit function enable Centre knobs: Setting of upper and lower level of cos 0.1 to 0.99. DWB01 Contact input U1 U2 cos j cos j I1 Z1 L1 L2 L3 16 18 Notes 1. DIP-switch 3 set ON enables the start/stop function that is managed by the closingopening of the contact input. 2. DIP-switch 3 set OFF enables the input contact for the latch/inhibit functions: the selection between these is allows by the DIP switch 4. 15 I2 The following table shows how the input contact manages the mode of operation: PWB01 Contact input Contact input working mode 9 8 cos j cos j 11 2 10 5 6 7 4 3 1 Specifications are subject to change without notice (09.12.05) LATCH INHIBIT START/STOP CLOSED NOT ACTIVE ACTIVE START OPEN ACTIVE NOT ACTIVE STOP 3 DWB01, PWB01 Wiring Diagrams DWB01 - Direct connection PWB01 - Direct connection L3 L2 L1 Latch/Inhibit Contact L3 L2 L1 Latch/Inhibit Contact m m U1 U2 I1 cos j cos j Z1 L1 L2 L3 16 18 9 I1 15 I2 8 I1 DWB01 - Standard CT 2 cos j cos j 5 6 7 4 1 10 11 PWB01 - Standard CT L3 L2 L1 Latch/Inhibit Contact L3 L2 L1 Latch/Inhibit Contact m cos j cos j Z1 L1 L2 L3 16 m 18 I1 2 cos j cos j U1 U2 5 6 7 4 3 9 I1 15 I2 I1 DWB01 - MI CT 8 11 1 10 PWB01 - MI CT L3 L2 L1 Latch/Inhibit Contact L3 L2 L1 Latch/Inhibit Contact m m Grey 3 U1 U2 cos j cos j I1 Z1 L1 L2 L3 16 18 Grey 9 8 15 I2 DWB01CM2310A - Direct connection - 1-Phase Load cos j cos j 11 2 5 6 7 4 3 1 10 PWB01CM2310A - Direct connection - 1-Phase Load L L N Latch/Inhibit Contact N Latch/Inhibit Contact m m cos j cos j Z1 L1 L2 L3 16 18 4 I1 5 6 7 4 3 9 U1 U2 cos j cos j 2 I2 15 8 11 10 1 Specifications are subject to change without notice (09.12.05) DWB01, PWB01 Wiring Diagrams (cont.) With the start/stop function enabled, it's necessary to use the following wiring diagrams (which are two examples among many others). It is possible for both 3-phase loads and 1-phase loads, either through direct connection or external current metering transformer. DWB01 - Direct connection - Manual start and stop (NE relay) PWB01 - Direct connection - Manual start and stop (NE relay) L3 L2 L1 N Start/stop Contact L3 L2 L1 N Start/stop Contact m m U1 cos j cos j U2 I1 I1 Z1 L1 L2 L3 18 16 9 I2 8 15 I1 cos j cos j 11 2 5 6 7 4 3 1 10 Operation Diagrams Latch function - NE relay Power supply Latch contact (Closed = latch not active) Upper Level Hysteresys Lower Level Hysteresys Power ON Relay ON T Power ON T T Inhibit function - ND relay Power supply Inhibit contact (Closed = inhibit active) Upper Level Hysteresys Lower Level Hysteresys Power ON Relay ON Power ON Start and stop function - NE relay Power supply Start/Stop contact (Closed = Start; Open = Stop) Upper Level Hysteresys Lower Level Hysteresys Relay ON Specifications are subject to change without notice (09.12.05) Power ON T T 5 DWB01, PWB01 Dimensions DIN-rail Plug-in 80 63 63 28.5 6 90 36 83.5 80 94 99.5 45 28.5 Specifications are subject to change without notice (09.12.05)