2007-04-26
3
BFR750L3RH
Electrical Characteristics at T
= 25°C, unless otherwise specified
Parameter Symbol Values Unit
min. typ. max.
AC Characteristics (verified by random sampling)
Transition frequency
IC = 60 mA, VCE = 3 V, f = 2 GHz fT- 37 - GHz
Collector-base capacitance
VCB = 3 V, f = 1 MHz, emitter grounded Ccb - 0.24 0.42 pF
Collector emitter capacitance
VCE = 3 V, f = 1 MHz, base grounded Cce - 0.31 -
Emitter-base capacitance
VEB = 0.5 V, f = 1 MHz, collector grounded Ceb - 0.97 -
Noise figure
IC = 25 mA, VCE = 3 V, f = 1.8 GHz, ZS = ZSopt
IC = 25 mA, VCE = 3 V, f = 6 GHz, ZS = ZSopt
F
-
-
0.6
1.1
-
-
dB
Power gain, maximum stable1)
IC = 60 mA, VCE = 3 V, ZS = ZSopt,
ZL = ZLopt , f = 1.8 GHz
Gms - 21 - dB
Power gain, maximum available1)
IC = 60 mA, VCE = 3 V, ZS = ZSopt,
ZL = ZLopt, f = 6 GHz
Gma - 11.5 - dB
Transducer gain
IC = 60 mA, VCE = 3 V, ZS = ZL = 50 Ω,
f = 1.8 GHz
IC = 60 mA, VCE = 3 V, ZS = ZL = 50 Ω,
f = 6 GHz
|S21e|2
-
-
18
8
-
-
dB
Third order intercept point at output2)
VCE = 3 V, IC = 60 mA, f = 1.8 GHz,
ZS = ZL = 50 Ω
IP3- 29.5 - dBm
1dB Compression point at output
IC = 60 mA, VCE = 3 V, ZS = ZL = 50 Ω,
f = 1.8 GHz
P-1dB - 16.5 -
1Gma = |S21e / S12e| (k-(k²-1)1/2), Gms = |S21e / S12e|
2IP3 value depends on termination of all intermodulation frequency components.
Termination used for this measurement is 50Ω from 0.1 MHz to 6 GHz