SXQ50 Series Single output DC/DC CONVERTERS 36-50W High Efficiency DC/DC Converters 1 * Surface mount quarter-brick format * High efficiency topology, 90% at 5V and 86.5% typical at 1.8V * Low profile, open-frame package * Wide operating temperature, -40C to +90C (with derating) * 90% to 110% output trim * No minimum load * Remote on/off The SXQ50 series are surface mount high-efficiency, isolated DC/DC converters in a standard quarter-brick format and a height of just 0.4 inches. The converters provide up to 50 Watts of output power and are capable of delivering very high current at low voltages. Patent pending technology ensures unprecedented levels of performance from a 50W surface-mount DC/DC converter. The first four models in the series feature an input voltage range of 33 to 75VDC and are available with output voltages of 5.0V, 3.3V, 2.5V or 1.8V. The output voltage of each model is adjustable from 90% to 110% of its nominal value. Typical efficiencies are 90% for the 5V model, 89% for the 3.3V, 88% for the 2.5V and 86.5% for the 1.8V. All SXQ50 series converters have a remote on/off capability, and are fully protected against over-voltage, over-temperature and short-circuit conditions. Featuring full international safety approval, including EN60950 (TUV Product Service) and UL/cUL 60950, SXQ50 series converters reduce compliance costs and time to market. TUV 2 YEAR WARRANTY SPECIFICATIONS All specifications are typical at nominal input, full load at 25C unless otherwise stated OUTPUT SPECIFICATIONS Total error band EMC CHARACTERISTICS (See Note 8) 4.5% Set point accuracy 2.0% max. Line regulation Low line to high line 0.3% max. Load regulation Full load to min. load 0.3% max. Voltage adjustability Output remote sense range 90% to 110% (See Note 9) 10% Minimum load Overshoot 0A At turn-on and turn-off Undershoot Ripple and noise None None 5Hz to 20MHz Transient response (See Note 1) 120mV pk-pk 30mV rms 5% max. deviation 200s recovery to within total error band Input current 48Vin nominal No load Remote OFF 33 to 75VDC 60mA 25mA Input current (max.) (See Note 3) Input reflected ripple Radiated emissions Immunity: ESD air ESD contact EFT DC Input Radiated field enclosure Conducted (DC power) Conducted (signal) Input transients EN55022 (See Note 2) EN55022 (See Note 2) EN55022 Level A Level B Level A EN61000-4-2 8kV, 15kV EN61000-4-2 6kV, 8kV EN61000-4-4, 2kV (NP) EN61000-4-3 10V/m EN61000-4-6 10V (NP) EN61000-4-6 10V (NP) ETS 300 132-2, ETR 283 GENERAL SPECIFICATIONS Efficiency See table Operational insulation Input/output Switching frequency Fixed Approvals and standards (See Note 4) 1500VDC 350kHz EN60950 (TUV Product Service) UL/cUL60950 Material flammability INPUT SPECIFICATIONS Input voltage range Conducted emissions 1.73A max. @ Io max. and Vin = 33 (See Note 5) Active high remote ON/OFF Logic compatibility ON OFF 110mA (pk-pk) (See Note 7) Open collector ref to -input Open circuit or <12VDC <1.2VDC Undervoltage lockout Power up Power down 32.5V 30.5V Start-up time (See Note 6) Power up Remote ON/OFF 10ms 3ms UL94V-0 Weight 25g (0.88oz) MTBF MIL-HDBK-217F @ 40C, 100% load ground benign >292,000 hours ENVIRONMENTAL SPECIFICATIONS Thermal performance Operating temperature -40C to +90C Non-operating -40C to +125C International Safety Standard Approvals UL/cUL CAN/CSA 22.2 No. 60950-00 : UL 60950 file No. E174104 TUV TUV Product Service. Certificate No. B 01 11 38572 029 File Name: SXQ50S.PDF Rev: 09 Oct 2002 SXQ50 Series Single output DC/DC CONVERTERS 36-50W High Efficiency DC/DC Converters 2 For the most current data and application support visit www.artesyn.com/powergroup/products.htm OUTPUT OUTPUT OUTPUT VOLTAGE CURRENT (MIN.) CURRENT (MAX.) 2.3VDC 1.8V 0A 33-75VDC 3.0VDC 2.5V 50W 33-75VDC 3.9VDC 50W 33-75VDC 6.0VDC INPUT POWER (MAX.) VOLTAGE 36W 33-75VDC 50W OVP OUTPUT REGULATION EFFICIENCY (10) (TYP.) LINE LOAD MODEL NUMBER (7, 11) 20A 86.5% 0.3% 0.3% SXQ50-48S1V8 0A 20A 88.0% 0.3% 0.3% SXQ50-48S2V5 3.3V 0A 15A 89.0% 0.3% 0.3% SXQ50-48S3V3 5.0V 0A 10A 90.0% 0.3% 0.3% SXQ50-48S05 Notes PROTECTION 1 di/dt = 0.1A/s, Vin = 48VDC, Tc = 25C, load change = 0.5 lo max. to 0.75 lo max. and 0.75 lo max. to 0.5 lo max. 2 The SXQ50 meets level A and level B conducted emissions only with external components connected before the input pins to the converter. See Application Note 120 for details. 3 Recommended input fusing is a 3.15A HRC 200V rated fuse. 4 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 5 Measured with no external Pi filter. Significant reduction possible with external filter. 6 Start-up into resistive load. 7 Active low remote ON/OFF is available. Standard product is active high. When ordering active low parts, designate with the Suffix `-R', e.g SXQ50-48S3V3-R. 8 This parameter is calculated at worst case line, load, temperature and initial settings. 9 This is inclusive of the output trim range. If 6.0% trim-up is used, for example, then only 4.0% output sense is available. 10 Maximum, not typical, specification. 11 To order an Evaluation Kit which contains a SXQ50 model pre-mounted on a circuit card with test points for easy testing in the laboratory, please add the suffix `-EVAL' to the model number, e.g. SXQ50-48S05-EVAL. Please see the SXQ50 Evaluation Board User Guide for further details. PIN CONNECTIONS FUNCTION 1 +Vin 2 On/Off 3 -Vin (<20m short) Continuous Overvoltage protection Non-latching clamp TELECOM SPECIFICATION Central office interface A ETS300-132-2, input voltage and current requirements CAUTION: Hazardous internal voltages and high temperatures. Ensure that unit is not user accessible. 2.3000.010 (58.420.25 0.055 (1.40) 0.055 (1.40) +Vin +Vout +Sense Trim -Sense -Vout Remote On/Off -Vin 1.4600.010 (37.080.25) PIN NUMBER Short circuit protection Converter Outline 3.0 mm x 1.7 mm 8 Places Top View 1.460 (37.08) -Vout 5 -Sense 0.000 (0.00) 0.000 (0.00) 0.057 (1.45) 2.186 (55.52) 0.057 (1.45) Connector, 0.053 x 0.102 (1.34x 2.59) 8 Places -Vout -Sense Trim +Sense +Vout -Vin Remote On/Off 0.435 (11.05) 0.300 (7.62) 0.600 (15.24) +Vin Bottom View 0.600 (15.24) +Vout 0.000 (0.00) 0.450 (11.43) 8 0.300 (7.62) +Sense 0.435 (11.05) 7 0.875 (22.23) 0.725 (18.42) 0.575 (14.61) 0.425 (10.80) Top View Seating Plane 0.150 (3.81) Trim 0.425 (10.80) Recommended Land Pattern 0.725 (18.42) Side View 6 1.025 (26.04) 1.025 (26.04) 0.017 (0.43) Min Clearance 0.4000.017 (10.160.44) Installed HT 2.243 (56.97) 2.300 (58.42) 4 All dimensions in inches (mm) All tolerance 0.010in (0.25mm) unless otherwise stated Data Sheet (c) Artesyn Technologies(R) 2002 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. Please consult our website for the following items: Application Note Longform Data Sheet www.artesyn.com File Name: SXQ50S.PDF Rev: 09 Oct 2002