Designed and built in Europe by:
82100-0062 Iss. 1A
Thurlby Thandar Instruments Ltd.
Glebe Road, Huntingdon. Cambs. PE29 7DR England
Tel: +44 (0)1480 412451 Fax: +44 (0)1480 450409
Email: info@aimtti.com Web: www.aimtti.com
AIM & THURLBY THANDAR INSTRUMENTS
TG120
20MHz function generator
●
0.2Hz to 20MHz frequency range
●
10mV to 20V pk-pk from 50
W
, plus TTL/CMOS output
●
DC offset control with zero detent
●
Variable symmetry control
●
External sweep input
●
Very low cost
An essential instrument
The function generator is one of the most versatile instruments
available.
It can generate a variety of precision waveshapes over a range
of frequencies from mHz to MHz. It can provide a wide range of
controlled amplitudes from a low impedance source and main-
tain constant amplitude as the frequency is varied.
Voltage control of frequency allows FM modulation to be intro-
duced or can provide a swept frequency source for such tasks
as frequency response testing.
20MHz from a low-cost generator
Most lower cost function generators use a technology which en-
ables them to operate up to no more than 2MHz.
The TG120 utilises an alternative technology which retains its
waveform quality right up to 20MHz.
Variable symmetry for pulse
and ramp waveforms
The TG120 provides switchable bi-directional variable symme-
try which enables variable duty cycle pulse waveforms and saw-
tooths to be generated.
Sweep mode operation (external)
The TG120 can be operated in sweep mode by connecting an
external sweep voltage. A sweep range of at least 20:1 can be
achieved.
Wide range level control
The TG120 provides a main output with a maximum emf of 20V
pk-pk from a 50Wsource.
An amplitude vernier with a range of 26dB is combined with two
-20dB switched attenuators to provide levels down to 10mV pk-
pk. Variable DC offset of ±10V is available via a centre detent
control.
An auxilliary output provides a fixed 0 to +5V level suitable for
driving both TTL and CMOS loads.
Technical Specifications
FREQUENCY
Frequency Range: 0.2Hz to 20MHz in 8 overlapping decade ranges with
fine adjustment by a vernier.
Vernier Range: >10:1 on each range.
Vernier Accuracy: Typically ±5% of full scale.
SWEEP MODE (EXTERNAL)
Input Impedance: 82 kW
Sweep Range: Typically > 20:1
Input Sensitivity: Typically 0 to 2V for 10:1 sweep
Max. Input Voltage: ±10V
Max. Slew Rate
of sweep voltage: 0.1V/us
OPERATING MODES
(Specifications apply for the top decade of each frequency range and output
10V peak-to- peak into 50Wtermination).
SINE
Distortion: Typically 2% on 200, 2k and 20k ranges.
Amplitude Flatness: ±0.2dB to 200kHz; ±2dB to 20MHz.
TRIANGLE
Linearity: Typically 99% on kHz ranges.
SQUAREWAVE
Rise and Fall Times: <22ns
DC
Range: ±10V from 50 W
SYMMETRY
Symmetry Range: Typically variable from 1:6 to 6:1 up to 500kHz.
OUTPUTS
50 W
Three switch-selectable ranges with 26dB vernier control within each range.
0dB Range: 1V to 20V peak-to-peak (0.5V to 10V into 50 W).
-20dB Range: 100mV to 2V peak-to-peak (50mV to 1V into 50 W)
-40dB Range: 10mV to 0.2V peak-to-peak (5mV to 0.1V into 50 W)
DC Offset Range: ±10V from 50 W. DC offset plus signal peak limited to
±10V (±5V into 50 W). DC offset plus waveform at-
tenuated proportionally in -20dB and -40dB position.
TTL/CMOS
Capable of driving 4 standard TTL loads.
GENERAL
Power: 230V or 115V nominal 50/60Hz, adjustable internally;
operating range ±14% of nominal; 30VA max. Installa-
tion Category II.
Operating Range: +5oC to + 40oC, 20% to 80% RH.
Storage Range: -10oC to +65oC
Environmental: Indoor use at altitudes to 2000m, Pollution Degree 1.
Electrical Safety: Complies with EN61010-1.
EMC: Complies with EN61236.
Size: 220(W) x 82(H) x 230(D) mm, (10.3 x 3.4 x 9.2") ex-
cluding feet.
Weight: 1.5 Kg (3.3lb).
TG120 Low-cost 20MHz function generator
Thurlby Thandar Instruments Ltd. operates a policy of continuous development and reserves
the right to alter specifications without notice.
Key features
●
0.2Hz to 20MHz frequency range
●
10mV to 20V pk-pk from 50
W
●
TTL/CMOS auxilliary output
●
DC offset control with zero detent
●
Variable symmetry control
●
External sweep input