Temperature
Compensating Type
High Dielectric
Constant Type
10 Adhesive Strength No removal of the terminations or other defect should occur. Solder the capacitor on the test jig (glass epoxy board)shown in
of Termination
Fig.3 using an eutectic solder. Then apply 10N* force in parallel
with the test jig for 10±1seconds.
The soldering should be done either with an iron or using the
reflow method and should be conducted with care so that the
soldering is uniform and free of defects such as heat shock.
*1N(GRM02),2N(GRM03),5N(GRM15,GRM18)
11 Vibration Appearance No defects or abnormalities.
Solder the capacitor on the test jig (glass epoxy board) in the same
Resistance manner and under the same conditions as (10).
Capacitance Within the specified tolerance. The capacitor should be subjected to a simple harmonic motion
having a total amplitude of 1.5mm, the frequency being varied
Q/D.F.
30pF and over:Q≧1000 [B1,B3,R1,R6,R7,C7,C8,L8] uniformly between the approximate limits of 10 and 55Hz. The
30pF and beloow:Q≧400+20C W.V.:100V :0.025max.(C<0.068mF) frequency range, from 10 to 55Hz and return to 10Hz, should be
:0.05max.(C≧0.068mF) traversed in approximately 1 minute. This motion should be
C:Nominal Capacitance(pF) W.V.:50V/25V :0.025max.
applied for a period of 2 hours in each 3 mutually perpendicular
directions(total of 6 hours).
W.V.:6.3V/4V :0.05max. (C<3.3mF)
[R9]
W.V.:50V: 0.05max.
[F1,F5]
W.V.:25Vmin
W.V.:16V/10V:0.125max.
W.V.:6.3V:0.15max.
12 Deflection Appearance No defects or abnormalities.
Solder the capacitor on the test jig (glass epoxy board) shown in
Fig.1 using an eutectic solder. Then apply a force in the direction
Within ±5% or± 0.5pF Within ±10% shown in Fig 2 for 5±1 seconds. The soldering should be done
Change (Whichever is larger) by the reflow method and should be conducted with care so that
the soldering is uniform and free of defects such as heat shock.
13 Solderability 75% of the terminations is to be soldered evenly and continuously. Immerse the capacitor in a solution of ethanol (JIS-K-8101) and
of Termination rosin (JIS-K-5902) (25% rosin in weight propotion) .
Preheat at 80 to 120℃ for 10-to 30 seconds.
After preheating, immerse in an eutectic solder solution for
2±0.5 seconds at 230±5℃ or Sn-3.0Ag-0.5Cu solder solution
for 2±0.5 seconds at 245±5℃.
14 Resistance to Appearance No defects or abnormalities.
Preheat the capacitor at 120 to 150℃ for 1 minute.
Immerse the capacitor in an eutectic solder solution* or
Within ±2.5% or± 0.25pF B1,B3,R1,R6,R7,R9,C7,C8,L8:Within ±7.5% Sn-3.0Ag-0.5Cu solder solution at 270±5℃ for 10±0.5 seconds.
Change (Whichever is larger) F1,F5 :Within ±20% Set at room temperature for 24±2 hours, then measure.
30pF and over:Q≧1000 [B1,B3,R1,R6,R7,C7,C8,L8]*Not apply to GRM02
30pF and beloow:Q≧400+20C W.V.:100V :0.025max.(C<0.068mF)
:0.05max.(C≧0.068mF) · Initial measurement for high dielectric constant type
C:Nominal Capacitance(pF) W.V.:50V/25V :0.025max.
Perform a heat treatment at 150+0/-10C for one hour and then set
at room temperature for 24±2 hours.
W.V.:6.3V/4V :0.05max. (C<3.3mF) Perform the initial measurement.
*Preheating for GRM32/43/55
W.V.:50V: 0.05max.
[F1,F5]
W.V.:25Vmin
W.V.:16V/10V:0.125max.
W.V.:6.3V:0.15max.
I.R.
More than 10,000MW or 500W·F(Whichever is smaller)
Strength
15 Temperature Appearance No defects or abnormalities.
Fix the capacitor to the supporting jig in the same
manner and under the same conditions as (10).
Within ±2.5% or± 0.25pF B1,B3,R1,R6,R7,R9,C7,C8,L8:Within ±7.5% Perform the five cycles according to the four heat
Change (Whichever is larger)
F1,F5 :Within ±20% treatments shown in the following table.
30pF and over:Q≧1000 [B1,B3,R1,R6,R7,C7,C8,L8]Set for 24±2 hours at room temperature, then measure.
30pF and beloow:Q≧400+20C W.V.:100V :0.025max.(C<0.068mF)
C:Nominal Capacitance(pF) W.V.:50V/25V :0.025max.
W.V.:16V/10V :0.035max.
W.V.:6.3V/4V :0.05max. (C<3.3mF)
W.V.:50V: 0.05max.
[F1,F5]
W.V.:25Vmin
· Initial measurement for high dielectric constant type
:0.05max. (C<0.1mF) Perform a heat treatment at 150+0/-10C for one hour and then set
:0.09max. (C≧0.1mF) at room temperature for 24±2 hours.
Perform the initial measurement.
More than 10,000MW or 500W·F(Whichever is smaller)
■SPECIFICATIONS AND TEST METHODS
Min.
Operating Temp.+0/-3
Max.
Operating Temp.+3/-0