LL
ABRACON IS
ISO9001-2015
CERTIFIED
5101 Hidden Creek Ln Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sales, please visit:
www.abracon.com
REVISED: 03.21.2019
ClearClock™ | Ultra-Low Jitter & Power Optimized 3.2 x 2.5 mm XO
Pb
3.2 x 2.5 x 1.0 mm
RoHS/RoHS II Compliant
MSL = 1
AX3 ESD Sensitive
Parameters Min. Typ. Max. Unit Notes
Frequency Range 100 200 MHz
Supply Voltage (Vdd) [Note 2]
2.97 3.3 3.63
V
Option A
2.37 2.5 2.62 Option B
1.71 1.8 1.89 Option C
Supply Current (Idd)
LVPECL 30 50
mA
Max. @ 200MHz; 3.3V
LVDS 16 27 Max. @ 200MHz; 3.3V
HCSL 17 30 Max. @ 200MHz; 3.3V
Operating Temperature Range -20 +70 °C Option “D”
-40 +85 Option “F”
Storage Temperature -55 +150 °C
Frequency Accuracy (Initial Set-Tolerance) at time of
shipment (Pre-Reow) @ +25°C -10 < ±5 +10 ppm Relative to carrier
Frequency Stability over Operating Temperature Range
(Relative to Post Reow Frequency)
-15 +15 ppm Over -20°C to +70°C
-25 +25 Over -40°C to +85°C
Aging over 20 Year Product Life [Note 3, 4] -15 +15 ppm
All-Inclusive Frequency Accuracy (Total Stability)
over 20 Year Product Life [Note 3]
-40 +40 ppm Over -20°C to +70°C
-50 +50 Over -40°C to +85°C
Rise (Tr) / Fall (Tf) Time (20% to 80% Vpp) 300 500 ps 20% to 80% Vpp
Duty Cycle 45 55 %
Startup Time [Note 3] < 2 5 ms
Output High Voltage (VOH)
Output Low Voltage (VOL)
LVPECL VOH Vdd-1.03 Vdd-0.60
V
50Ω to Vdd–2.0V or
Thevenin equivalent
VOL Vdd-1.85 Vdd-1.60
LVDS VOH 1.40 1.60 100Ω between
OUT-P and OUT-N
VOL 0.9 1.10
HCSL VOH 0.66 0.74 0.85 50Ω to Ground
VOL -0.15 0 0.15
Output
Enable & Disable Control
0.7*(Vdd)VOutput Enable; or No Connect
0.3*(Vdd) Output Disable; High Impedance
Output Enable Time 10 ms
Output Disable Time 0.2 μs
Output Disable Current Consumption < 10 μA OE ≤ 0.3V
RMS Phase Jitter (12kHz-20MHz BW) ≤ 75 150 fs @156.25MHz, 3.3V, LVPECL
Note 2: Supply Voltage (V dd) = 1.8V option not available with LVPECL output
Note 3: Relative to initial measured frequency @ +25°C
Note 4: Includes temperature stability, initial frequency accuracy, load pulling, power supply variation, and 20 year aging
Electrical Characteristics