PRODUCT INFORMATION
0.01
0.1
1
10
100
1 10 100 1000 10000
Gas Concentration (ppm)
Air
CO
Ethanol
H2
0.1
1
10
100
1000
-20 -10 0 10 20 30 40 50 60
Temperature (˚C)
Air
CO 30ppm
CO 100ppm
CO 300ppm
50%RH
Applications:
Features:
TGS 2442 - for the detection of Carbon Monoxide
The figure below represents typical sensitivity characteristics,
all data having been gathered at standard test conditions (see
reverse side of this sheet). The Y-axis is indicated as sensor
resistance ratio (Rs/Ro) which is defined as follows:
Rs = Sensor resistance of displayed gases at
various concentrations
Ro = Sensor resistance in 100ppm CO
The figure below represents typical temperature and humidity
dependency characteristics. Again, the Y-axis is indicated as
sensor resistance ratio (Rs/Ro), defined as follows:
Rs = Sensor resistance at 30ppm, 100ppm and 300ppm
of CO at various temperatures and 50%R.H.
Ro = Sensor resistance at 300ppm of CO
at 25°C and 50% R.H.
* CO detectors
* Air quality controllers
* Indoor parking lot ventilation
TGS 2442 utilizes a multilayer sensor structure. A glass layer for thermal insulation is
printed between a ruthenium oxide (RuO2) heater and an alumina substrate. A pair of
Au electrodes for the heater are formed on a thermal insulator. The gas sensing layer,
which is formed of tin dioxide (SnO2), is printed on an electrical insulation layer which
covers the heater. A pair of Au electrodes for measuring sensor resistance are formed
on the electrical insulator. Activated charcoal is filled between the internal cover and
the outer cover for the purpose of reducing the influence of noise gases.
TGS 2442 displays good selectivity to carbon monoxide, making it ideal for CO
monitors. In the presence of CO, the sensor's conductivity increases depending
on the gas concentration in the air. A simple pulsed electrical circuit operating on a
one second circuit voltage cycle can convert the change in conductivity to an output
signal which corresponds to gas concentration.
* Low power consumption
* High sensitivity/selectivity to
carbon monoxide (CO)
* Miniature size
* Low sensitivity to alcohol vapor
* Long life and low cost
* Low humidity dependency
Temperature/Humidity Dependency:
Sensitivity Characteristics:
IMPORTANT NOTE: OPERATING CONDITIONS IN WHICH FIGARO SENSORS ARE USED WILL VARY WITH EACH CUSTOMER’S SPECIFIC APPLICATIONS. FIGARO STRONGLY REC-
OMMENDS CONSULTING OUR TECHNICAL STAFF BEFORE DEPLOYING FIGARO SENSORS IN YOUR APPLICATION AND, IN PARTICULAR, WHEN CUSTOMER’S TARGET GASES
ARE NOT LISTED HEREIN. FIGARO CANNOT ASSUME ANY RESPONSIBILITY FOR ANY USE OF ITS SENSORS IN A PRODUCT OR APPLICATION FOR WHICH SENSOR HAS NOT
BEEN SPECIFICALLY TESTED BY FIGARO.