Bel Power Solutions MAP110 Series of power supplies combines low cost and universal input in a board-only power solution to meet commercial and industrial requirements. Full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units bear the CE Mark. Wide dynamic output current and fixed-frequency operation simplifies system level operation. The MAP110 series is configured to an international standard footprint. Input and output connections are made via popular single-row Molex connectors. Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements. RoHS Lead-Solder-Exemption Compliant New 5 V Output Models Universal Input 85-264 VAC Industry-Standard Footprint: 7.0" x 4.3" x 1.97" (177.8 x 109.2 x 50.0 mm) Input Transient & ESD Compliance to EN61000-4-2/-3/-4 Remote sense and overvoltage protection on single output units and main output of multiple output units Options include Over temperature protection, Power Fail signal, Chassis & Cover Greater than 134,000 hours MTBF MAP110 Series 2 MODEL 7 OUTPUT VOLTAGE ADJUSTMENT RANGE CONVECTION COOLED OUTPUT CURRENT FORCED AIR OUTPUT CURRENT 1 LINE REGULATION LOAD REGULATION RIPPLE & NOISE 2 INITIAL SETTING ACCURACY MAP110-1005* 5V 4.95V to 5.5V 16A 22A 0.2% 1% 1% 5.09V to 5.11V MAP110-1012G 12V 11.25V to 12.75V 7.5A 0.1% 0.5% 1% 11.97V to 12.02V 0.1% 0.5% 1% 23.95V to 24.05V MAP110-1024G MODEL 7 24V/28V 22.8V to 29.2V 3.8/3.2A 10A 3 5/4.3A 3 OUTPUT VOLTAGE ADJUSTMENT RANGE CONVECTION COOLED OUTPUT CURRENT 4 FORCED AIR OUTPUT CURRENT 4 LINE REGULATION LOAD REGULATION RIPPLE & NOISE2 INITIAL SETTING ACCURACY +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +12V Fixed 5A/9A PK 5A/9A PK 0.2% 1% 1% 11.97V to 12.03V -12V Fixed 1A/1.5A PK 1A/1.5A PK 0.2% 1% 1% -11.4V to -12.6V MAP110-4000G -5V Fixed 1A/1.5A PK 1A/1.5A PK 0.2% 1.5% 1% -4.75V to -5.25V +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +24V Fixed 3A/4.5A PK 3A/4.5A PK 0.1% 1% 1% 23.94V to 24.06V -12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -11.4V to -12.6V +12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 11.4V to 12.6V +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +12V Fixed 5A/9A PK 5A/9A PK 0.1% 1% 1% 11.97V to 12.03V -12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -11.4V to -12.6V +12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 11.4V to 12.6V MAP110-4001* MAP110-4002G +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +15V Fixed 5A/7.3A PK 5A/7.3A PK 0.1% 1% 1% 14.96V to 15.04V -15V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -14.3V to -15.7V -5V Fixed 1A/1.5A PK 1A/1.5A PK 0.2% 1.5% 1% -4.75V to -5.25V MAP110-4003* +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +24V Fixed 3A/4.5A PK 3A/4.5A PK 0.1% 1% 1% 23.94V to 24.06V -15V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -14.3V to -15.7V +15V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 14.3V to 15.7V +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +12V Fixed 5A/9A PK 5A/9A PK 0.1% 2% 1% 11.97V to 12.03V -5V Fixed 1A/1.5A PK 1A/1.5A PK 0.2% 1.5% 1% -4.75V to -5.25V MAP110-4004G MAP110-4010* -12V Fixed 3A/4A PK 3A/4A PK 0.3% 8% 1% -11.5V to -12.5V +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +12V Fixed 5A/9A PK 5A/9A PK 0.1% 1% 1% 11.97V to 12.03V -12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -11.4V to -12.6V MAP110-4011G +24V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 23.2V to 24.8V +5V 4.75V to 5.25V 12A/20A PK 12A/20A PK 0.2% 0.5% 1% 5.09V to 5.11V +12V Fixed 5A/9A PK 5A/9A PK 0.1% 1% 1% 11.97V to 12.03V MAP110-4015* tech.support@psbel.com MAP110 Series -15V MAP110-4200G MAP110-4300* 5,6 MAP110-4305* 5,6 3 Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -14.4V to -15.6V 1% 1% 14.4V to 15.6V +15V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% +12V 11.55V to 12.45V 5A/9A PK 5A/9A PK 0.2% 0.5% 0.5% 11.96V to 12.03V +24V Fixed 4A/4.5A PK 4A/4.5A PK 0.2% 1% 1% 23.94V to 24.06V -12V Fixed 1A/1.5A PK 1A/1.5A PK 0.2% 1% 1% -11.4V to -12.6V +5V Fixed 2A/2.5A PK 2A/2.5A PK 0.2% 1.5% 1% 4.75V to 5.25V +3.3V 3.2V to 3.4V 12A/20A PK 15A/20A PK 0.3% 0.7% 1% 3.29V to 3.31V +5V Fixed 5A/12A PK 8A/12A PK 0.2% 1% 1% 4.98V to 5.02V -12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -11.4V to -12.6V +12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 11.4V to 12.6V +3.3V 3.2V to 3.4V 12A/15A PK 15A/20A PK 0.3% 0.7% 1% 3.29V to 3.31V +5V Fixed 5A/12A PK 8A/12A PK 0.2% 1% 1% 4.98V to 5.02V -5V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% -4.75V to -5.25V +12V Fixed 1A/1.5A PK 1A/1.5A PK 0.1% 1% 1% 11.4V to 12.6V 1 With minimum 200LFM forced-air cooling. Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 3 MAP110-1024 output currents are expressed as 24V/28V operation. 4 Peak loads up to 110 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 110 watts. 5 Sum of the output currents of V1 + V2 may not exceed 15 A continuous, 22 A peak. 6 Maximum operating ambient temperature of 40C 7 Non-G models use lead solder exemption and are not recommended for new designs. * Obsolete 2 *O MODEL/OUTPUT OPTION MULTIPLE OUTPUT BOARD ONLY SINGLE OUTPUT BOARD ONLY MULTIPLE OUTPUT `C'-COVER SINGLE OUTPUT C'-COVER Convection Continuous / Peak 80W/110W 90W/120W 60W/110W 65W/120W Forced Air 200 LMF 110W 120W 110W 120W PARAMETER CONDITIONS / DESCRIPTION Input Voltage - AC Continuous input range Input Frequency AC input Brown Out Protection Hold-up Time Input Current MIN Lowest AC input voltage when regulation is maintained with full rated loads. Nominal AC input voltage (110 VAC) 50% load: Full rated load: 85 VAC (110W load) 110VAC (110W load) Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 264 VAC (one cycle). 25 C. Operating Frequency Switching frequency of main transformer, (fixed frequency). NOM MAX UNITS 85 264 VAC 47 63 Hz 85 VAC 40 20 mS 20 3.5 2.8 ARMS 41 APK 25 kHz Europe, Middle East +353 61 225 977 North America +1 408 785 5200 (c) 2016 Bel Power Solutions & Protection BCD.00566_AB Asia-Pacific +86 755 298 85888 MAP110 Series 4 PARAMETER CONDITIONS / DESCRIPTION Efficiency Minimum Loads Full load @ 230 VAC (Varies with distribution of loads among outputs.) Single output models Multiple output models, V1 + V28 Ripple and Noise Full Load, 20 MHz Bandwidth. Output Power Multiple output units with convection cooling. Multiple output units with 200 LFM forced air cooling. Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on. Regulation Transient Response Time required for initial output voltage stabilization. Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. NOM MAX UNITS 70% typical 0 1 Amps See Model Selection Chart 5 5 Varies by output, regulation includes: line changes from 90-132 VAC or 175-264, changes in load starting at 20% load and changing to 100% load. Recovery time, to within 1% of initial set point due to a 50-100% load change, 4% max. deviation. (Main output only on multiple output units). Turn-on Delay 8 MIN 80 110 Watts 1 % See Model Selection Chart 500 S 1 Sec 20 mS Minimum load is required only to meet the regulation limits of V3 and V4. If V3 and V4 are unused, no minimum load is necessary. PARAMETER Overvoltage Protection Overload Protection CONDITIONS / DESCRIPTION MIN MAP110-1005G MAP110-1012G Provided on single output models and the MAP110-1024G main output of multiple output models. MAP110-4200G MAP110-4300G All other models Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. 6.10 17.3 32.2 13.8 3.7 5.75 Remote Sense Voltage drop compensated for at the load. Input Power Fail Warning Option, TTL compatible logic signal. Time before regulation dropout due to loss of input power at 110 VAC. Active low. Over temperature Protection Option, system shutdown due to excessive internal temperature. PARAMETER CONDITIONS / DESCRIPTION Agency Approvals Dielectric Withstand Voltage Electromagnetic Interference, Conducted Approved to the latest edition of the following standards; UL/CSA60950-1 2nd, IEC60950-1 2nd and EN60950-1 2nd. Input to Chassis Input to Output (tested by manufacturer only) FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated EN55022 / CISPR 22 conducted EN55022 / CISPR 22 radiated9 NOM 150 3 MIN MAX UNITS 7.20 20.2 37.8 16.2 4.35 6.75 V 200 % 250 mV 5 NOM mS MAX 2121 4242 UNITS VDC B B A Class Input Transient Protection EN61000-4-5 Level 3 2 kV Insulation Resistance Input to output 10 M Leakage Current Per EN60950, 264 VAC 9 The 750 A following units meet Class B: MAP110-1005, MAP110-4000/4011/4015/4200/4300. tech.support@psbel.com MAP110 Series PARAMETER Altitude Operating Temperature 5 CONDITIONS / DESCRIPTION MIN Operating Non-operating Derate linearly above 50C by 2.5% per C to a max. temp. of 70C At 100% load: At 50% load: Storage Temperature 0 0 -55 Temperature Coefficient 0C to 70C (after 15 minute warm-up) Relative Humidity Non-condensing 0.03 PARAMETER CONDITIONS / DESCRIPTION Dimensions 177.8 x 109.2 x 50.0 mm (7.00 x 4.30 x 1.97 inch) Weight 0.59 kg (1.3 lbs) Cover Add `C' suffix to model number (Please check with Factory for availability) Power Fail Signal Thermal Shutdown NOM MAX UNITS 10k 50k ASL Ft. 50 70 C 85 C 0.05 %/C 95 %RH Add `P' suffix to model number. Provides >5 mS typical warning time before main output drops 5%. Warning time increases at reduced load levels. Add `T' suffix to model number. Initiates shut-down in the event of an over temperature condition. Automatic recovery. Please consult factory regarding availability of a specific version. Europe, Middle East +353 61 225 977 North America +1 408 785 5200 (c) 2016 Bel Power Solutions & Protection BCD.00566_AB Asia-Pacific +86 755 298 85888 MAP110 Series 6 Figure 1. Mechanical Drawing NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. tech.support@psbel.com