Surge Protection Module LED Lighting Surge Protection Module > LSP05GI LSP05GI Module Series RoHS Description Littelfuse's LSP05GI thermally protected Surge Protective Device is a self-protected device specially designed to be used in outdoor and commercial LED lighting fixtures for transient overvoltage protection. It has been developed with Littelfuse's thermally protected varistor technology. Its built-in thermal disconnect function provides additional protection to prevent catastrophic failure and fire hazard even under extreme circumstances of varistor end-of-life or sustaining over voltage conditions. The LSP05GI features a built-in LED indicator that notifies when replacement of the module is needed. Features Agency Approvals Agency Standard Agency File Number UL 1449 E320116 + ++ IEC 61643-11 NL-40819 ++ 3177948.01 EN 61643-11 + = For 120V, 240V and 277V ++ = For 240V and 277V Additional Information * Build-in LED Indication, saves maintenance time by identifying replacement need * Thermally Protected * Suitable for use in luminaire with Class I or Class II insulation* * 10kA Maximum Discharge Current (Imax), 8/20s * Meets ANSI C82.77-5-2015: Location C Medium * Meets ANSI C136.2-2015: Enhanced Level * Meets IEEE C62.41.2: Location Category C Low * Meets US Dept. of Energy MSSSLC Model Spec. * High line-to-earth/ground resistance * IP66: Dust-tight and water resistant * Parallel or Series connected options * UL 1449 and IEC 61643-11/EN 61643-11 recognized* * See `Part Numbering System' for exact details of voltages available for Class I and Class II installations, and `Device Ratings and Specifications' table for voltage specific approvals. Applications Datasheet Resources Samples * * * * * * * * * Outdoor and Commercial LED Lighting Roadway lighting Traffic lighting Digital signage Wall wash lighting Parking garage lighting Flood lighting Tunnel lighting Street lighting (c) 2018 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 08/22/18 Surge Protection Module LED Lighting Surge Protection Module > LSP05GI Absolute Maximum Ratings * For ratings of individual members of a series, see Device Ratings and Specifications chart LSP05GI Series Units Continuous: Steady State Applied Voltage: Max AC Voltage Range (VM(AC)RMS) 150 to 510 V 3.5 A Continuous Current Transient: Maximum Discharge Current, 8/20s Waveform (Imax) 10,000 A Nominal Discharge Current, 8/20s Waveform (In) 5,000 A Operating Ambient Temperature Range (TA) -40 to +85 C Storage Temperature Range (TSTG) -40 to +85 C Isolation Voltage Capability (When the thermal disconnect opens) Insulation Resistance 600 V >1,000 M CAUTION: Stresses above those listed in `Absolute Maximum Ratings' may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. LSP05GI Series Device Ratings and Specifications Part Number Operating Voltage (VAC) MCOV/UC 1 (VAC) Maximum Discharge Current 2 Imax (A) Nominal Discharge Current 3 In (A) MLV 4 (V) Up (V) LSP05GI120* 120 150 10,000 5,000 L-N:650 L-G:1280 N-G:1230 LSP05GI240* 240 275 10,000 5,000 LSP05GI277* 277 320 10,000 LSP05GI347* 347 420 LSP05GI480* 480 LSP05GI120*H 5 Safety Compliance IEC/EN 61643-11 UL1449 -- -- X L-N:1080 L-G:1230 N-G:1340 L-N: 1300 L-G/PE: 2400 N-G/PE: 2200 X X 5,000 L-N: 1260 L-G: 1260 N-G:1300 L-N: 1400 L-G/PE: 2400 N-G/PE: 2200 X X 10,000 5,000 L-N: 1530 L-G: 1550 N-G: 1410 -- -- -- 510 10,000 5,000 L-N: 1800 L-G: 1900 N-G: 1410 -- -- -- 120 150 10,000 5,000 L-N: 650 L-G: 3150 N-G: 3210 -- -- X LSP05GI240*H 240 275 10,000 5,000 L-N: 1080 L-G: 3170 N-G: 3430 -- -- X LSP05GI277*H 277 320 10,000 5,000 L-N: 1260 L-G: 3160 N-G: 3310 -- -- X LSP05GI480*H 480 510 10,000 5,000 L-N: 1800 L-G: 3090 N-G: 3090 -- -- -- * = S or P = Module with `H' designation features 1500Vac Hi-Pot withstand capability in common mode (L-G and N-G). Glossary: 1. MCOV/UC: Maximum Continuous Operating Voltage - maximum r.m.s. voltage that could be continuously applied to the SPD. 2. Maximum Discharge Current Imax (A): The maximum discharge current is a measure of the SPDs maximum capability; single impulse of discharge current uses the 8/20s current waveform. All Devices pass maximum discharge current with possible, safe opening of thermal disconnect. 3. Nominal Discharge Current In (A): The nominal discharge current is a measure of the SPDs endurance capability; 15 impulses of discharge current uses the 8/20s current waveform. 4. MLV: UL1449 Measured limiting voltage; the highest value of residual voltage measurements during the application of impulses of 8/20s nominal discharge current (In); an average voltage value of 15 impulses. 5. Up: IEC 61643-11 Voltage protection level; the highest value of residual voltage measurements during the application of impulses of 8/20s nominal discharge current (In); a rounding voltage value of maximum measurement. (c) 2018 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 08/22/18 Surge Protection Module LED Lighting Surge Protection Module > LSP05GI Specification Value Condition 240V 277V Temporary Overvoltage (V) TOV UT @ tT = 5 s 337 403 LV System Fault for TN Power Grid Temporary Overvoltage (V) TOV UT @ tT = 120 min 442 529 LV System Fault for TN Power Grid Power grids TN TN Backup fuse (A) 16 20 Maximum gG Fuse End of life indication Yes Yes Optical Light ON: SPD is functional Light OFF: SPD has reached end-of-life Max earth leakage current at Uc (A) 50 50 IEC 61643-11 Test Classification Test Class II and III Test Class II and III EN 61643-11 Type Classification Type 2 and 3 Type 2 and 3 4CA 4CA UL 1449 Type Repetitive Surge Capability Pulse Rating (8x20Sec) 100000 MODEL SIZE = 20MM TA = -55oC TO 85oC 130 to 625VM(AC) RATING 1 SURGE CURRENT (A) 10000 2 15 1000 Strikes Surge 1 10,000A 2 7,000A 15 5,000A 100 1,500A 1,000 700A 500+20 10 2 10 4 5 10 10 6 10 3 100 10 1 10 100 1000 10000 IMPULSE DURATION (s) LSP05GI Series Wire Specification Part Number Extension Length Diameter Double Insulation Installation Class Color X3333 250mm 20mm 1mm2 Yes I L - Brown N - Blue G/PE - Green with Yellow stripe X3316 250mm 20mm 1mm2 Yes II L - Brown N - Blue None 250mm 20mm 16AWG Yes -- L - Black N- White G- Green (c) 2018 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 08/22/18 Surge Protection Module LED Lighting Surge Protection Module > LSP05GI Dimensions Series Version Parallel Version LED Indication LED Indication 26.00 1.50 26.02 1.50 62 468 56.76 2.00 17.48 1.50 O6.400.30 25020 25020 468 62 62 Output Input 47.69 2.00 468 47.69 2.00 25020 56.76 2.00 O6.400.30 46.36 2.00 17.481.50 46.362.00 Note: Dimensions are in millimeters (mm) Part Numbering System Application/Installation Schematic L L N N G/PE G/PE Littelfuse Surge Protection Module 5kA (Nominal Discharge Current) SPD Series Connection LSP 05G I 120 P H Xxxxx AC/DC Power Supply X3333 Built-in LED indication Operating Voltage L L N N X3316 (for Class II Unearthed) G/PE L N G/PE Parallel Connection L N P: Parallel connection S: Series connection Blank: Normal mode H: With 1500Vac Hi-Pot withstand capability in common mode (L-G and N-G) SPD Series Connection N Power Supply G/PE L AC/DC AC/DC Power Supply SPD X3333 L AC/DC N Supply G/PE Parallel Connection Power SPD X3316 (for Class II Unearthed) Note: Green LED light on: SPD is good Green LED light off: SPD needs replacement (c) 2018 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 08/22/18 Other Options: X3333: with GND wire connection, available for 240Vac and 277Vac rating with CE Marking for Class I earthed luminaire installation Wire Color: Line: Brown, Neutral: Blue, Ground/PE: Green with yellow stripe X3316: without GND wire connection, available for 240Vac and 277Vac rating with CE Marking for Class II unearthed luminaire installation Wire Color: Line: Brown, Neutral: Blue