Click on Series name for product info on aimtec.com Series AMER120-CAZ up to 5A | AC-DC / DC-DC | LED Driver / Converter FEATURES: * Constant Current or Constant Voltage LED Driver or Converter * Input range 90-305VAC/47-440Hz * 115VAC Operating temperature -50 to 85C * 230VAC Operating temperature -55 to 85C * Dimmable via resistive * 5 Years Limited Warranty Models Single output Max Output Power (W) Output Voltage Range (V) Output Current (A) Input Voltage (VAC/Hz) Input Voltage (VDC) AMER120-50250CAZ 125 36-50 0-2.5 90-305/47-440 130-430 AMER120-36340CAZ 122.4 24-36 0-3.4 90-305/47-440 130-430 AMER120-24500CAZ 120 12-24 0-5 90-305/47-440 130-430 Add Suffix "-F" No dimming option Model * * * * * Short Circuit Protection Over Current Protection Waterproof Case rated IP68 Power Factor Correction High Efficiency up to 88% Mode of Operation Efficiency (%) 115 230 277 VAC VAC VAC Constant Voltage Constant Current 87 87 87 87 85 88 88 88 88 86 86 88 88 88 87 Constant Voltage 86 86 87 Constant Current Voltage Constant Constant Current Exceeding the maximum output power will permanently damage the converter. feature is not supported when units are used in Constant Voltage mode only, Aimtec suggests to order "-F" No dimming option in the case. In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add "-NA" to part number when ordering. NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25C, humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See http://www.aimtec.com/terms-sale AMER120-CAZ's AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are prone to `dirty' electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations prior to installation may damage sensitive equipment permanently. The dimming Input Specifications Parameters Current (full load) Inrush current <2ms (cold start) Leakage current Power factor External fuse Start-up time Conditions Typical 115 VAC 230 VAC 277 VAC 115 VAC 230 VAC 277 VAC I/O I/FG, O/FG 115 VAC 230 VAC 277 VAC Recommended slow blow type Maximum 1800 800 700 45 60 70 0.25 3.5 0.98 0.94 0.92 3 900 Units mA mA mA A A A mA mA A ms Output Specifications Parameters Current accuracy www.aimtec.com F 052.1e R3.R Conditions Typical 3 Tel: +1 514 620 2722 1 of 10 Maximum Units % Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120-CAZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Line regulation Load regulation Ripple & Noise Hold-up time Current adjustment range Minimum Load Voltage LL-HL 0-100% load 20MHz Bandwidth 2 3 150 % % mV p-p 80 100-10 ms % See the models table Ripple and Noise are measured at 20MHz bandwidth by using a 0.1F (M/C) or (C/C) and 47F (E/C) parallel capacitor. Note: from 0% to 10% dimming adjustment signal instability may be present. Isolation Specifications Parameters Tested voltage Conditions I/O I/FG O/FG Isolation resistance Typical 3sec 500VDC Rated Units 3750 2000 500 VAC VAC VAC M >1000 General Specifications Parameters Conditions Typical Maximum Units 125 2.57 3.47 5.07 KHz Switching frequency Over current protection Over voltage protection Short circuit protection Short circuit restart Operating temperature (See Derating Table) Cold Start-up Time Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Case material Potting Wires Weight Dimensions (L X H X W) MTBF AMER120-50250CAZ AMER120-36340CAZ AMER120-24500CAZ Refer to Constant Current vs. Constant Voltage Mode curve Continuous Auto recovery (115VAC) -50 to +85 (230VAC) -55 to +85 -55C oC oC 30 100 Sec oC oC % / oC 95 % RH -55 to +95 0.02 Free air convection Aluminum Epoxy (IP68 rated) UL1015 18AWG Input & 14AWG Output *20CM 900 7.13 x 2.32 x 1.85 inches 181.00 x 59.00 x 47.00 mm >400,000 hrs (MIL-HDBK-217F at +25C) A g Safety Specifications Parameters Agency approvals Standards www.aimtec.com F 052.1e R3.R CE Designed to meet UL8750, IEC/EN 60950-1 standards, EN55022, class B, EN60529(IP68) Information Technology Equipment EN55022 Class B Harmonic Current Emissions IEC/EN 61000-3-2, Class C Voltage fluctuations and flicker IEC/EN 61000-3-3, (EN60555-3) Electrostatic Discharge Immunity IEC 61000-4-2 Level 3 RF, Electromagnetic Field Immunity IEC 61000-4-3 Level 2 Electrical Fast Transient / Burst Immunity IEC 61000-4-4 Level 2 Surge Immunity IEC 61000-4-5 Level 3 RF, Conducted Disturbance Immunity IEC 61000-4-6 Level 2 Power frequency Magnetic Field Immunity IEC 61000-4-8 Level 1 Voltage dips, Short Interruptions Immunity IEC 61000-4-11 Tel: +1 514 620 2722 2 of 10 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120-CAZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Dimensions Top View 181.00 (7.13) 4.00 (0.16) 41.00 (1.73) 27.00 (1.06) 8.00 (0.32) 11.00 (0.43) End View Tc 23.00 (0.91) Side View 200.00 (8.00) 47.00 (1.85) 200.00 (8.00) 59.00 (2.32) 2.30 (0.09) Input/Output Wires are 18 AWG 20cm Measurements in Millimeters (inch) Case Tolerance: 0.5 (0.02) Wire connection: Connection Wire Brown Blue Green Red Black Blue (Dimming) White (Dimming) AC L AC N Ground +V output -V Output + Vs dimming -Vs dimming Analog (resistive) Dimming Application Circuit BROWN +Vout RED L GREEN 1st LED 1 AC AMER120-AZ BLUE -Vout N WHITE F 052.1e R3.R AMER120-50250CAZ AMER120-36340CAZ AMER120-24500CAZ Maximum Pot Value (k) 18.22 22.10 34.31 1 BLUE www.aimtec.com Model Number BLACK Pot Tel: +1 514 620 2722 3 of 10 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120-CAZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Analog (0-10V) Dimming Application Circuit PWM (1KHz) Dimming Application Circuit Derating Free Air Convection 55 C 100 80 Safe Operating Area 60 40 20 0 -40 -20 0 20 40 60 80 85 100 Ambient Temperature C www.aimtec.com F 052.1e R3.R Tel: +1 514 620 2722 4 of 10 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120-CAZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Efficiency vs. Input Voltage and Output Current (CC Load) AMER120-50250CAZ (%) Efficiency VS. Input Voltage & Output Current 115Vac, 0.5, 87.03 277Vac, 2.5, 230Vac, 2.5, 90.54115Vac 115Vac, 2.5, 90.46230Vac 90.16 277Vac 277Vac, 0.5, 230Vac, 81.160.5, 80.4 (A) AMER120-36340CAZ (%) Efficiency VS. Input Voltage & Output Current 87.37 89.92 89.73 88.74 115Vac 230Vac 277Vac 277Vac, 0.68, 82.711 80.85 (A) www.aimtec.com F 052.1e R3.R Tel: +1 514 620 2722 5 of 10 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120-CAZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Efficiency vs. Input Voltage and Output Current (CC Load) Continued AMER120-24500CAZ (%) Efficiency VS. Input Voltage & Output Current 277Vac,115Vac 5, 230Vac, 88.5315, 115Vac, 5, 88.374230Vac 87.409277Vac 115Vac, 1, 86.912 277Vac, 1, 80.9441, 230Vac, 79.913 (A) PFC Value vs. Output Load Current (CC Load) AMER120-50250CAZ (PF) PFC VS. Output Voltage 115VAC, 230VAC, 36, 1 277VAC, 0.974 36, 0.949 297VAC, 36, 0.836 115VAC, 50, 230VAC, 50, 0.997 50, 277VAC, 115VAC 0.984 0.969 297VAC, 50, 230VAC 0.868 277VAC 297VAC 305VAC 305VAC, 36, 0.502 305VAC, 50, 0.516 (V) www.aimtec.com F 052.1e R3.R Tel: +1 514 620 2722 6 of 10 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120-CAZ up to 5A | AC-DC / DC-DC | LED Driver / Converter PFC Value vs. Output Load Current (CC Load) AMER120-36340CAZ (PF) PF VS. Output Voltage 115VAC, 24, 230VAC, 0.998 24, 277VAC, 0.97 24, 0.938 294VAC, 24, 0.787 305VAC, 24, 0.502 115VAC, 36, 115VAC 230VAC, 36,1 277VAC, 36, 0.985 230VAC 294VAC, 0.969 36, 277VAC 0.882 294VAC 305VAC 305VAC, 36, 0.518 (V) AMER120-24500CAZ (PF) PF VS. Output Voltage 115VAC, 12, 230VAC, 0.998 12, 277VAC, 0.953 12, 0.91 297VAC, 12, 0.755 115VAC, 24, 230VAC, 24, 1 115VAC 277VAC, 0.986 24, 230VAC 0.97 297VAC, 24, 277VAC 0.848 297VAC 305VAC 305VAC, 12, 0.492 305VAC, 24, 0.519 (V) www.aimtec.com F 052.1e R3.R Tel: +1 514 620 2722 7 of 10 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120-CAZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Constant Current Mode vs. Constant Voltage Mode AMER120-50250CAZ (A) Constant Current Vs Constant Voltage 115 & 230 Vac, 36, 2.5 115 & 230 Vac, 50, 2.5 36 38 40 115 & 230115 & 230 Vac, 50.8, Vac, 0 52, 0 (V) AMER120-36340CAZ (A) Constant Current Vs Constant Voltage 115 & 230 Vac, 24, 3.4 24 26 28 30 36 115 & 230 115 & 230 Vac, 36.5, 0 Vac, 38, 0 (V) www.aimtec.com F 052.1e R3.R Tel: +1 514 620 2722 8 of 10 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120-CAZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Constant Current Mode vs. Constant Voltage Mode AMER120-24500CAZ (A) Constant Current Vs Constant Voltage 115 & 230 Vac, 12, 5 115 & 230 Vac, 24, 5 12 14 16 115 & 230 115 & 230 Vac, 24.39, 0Vac, 26, 0 (V) Output Current vs. Radj AMER120-50250CAZ (A) Output Current VS. Dimming-Resistance 115 & 230 115 & 230 Vac, 3.2, 2.25 Vac, 1.6, 2 115 & 230 115 230 Vac,&0.966, 115 230 Vac,& 0.641, 1.75 Vac, 0.437, 115&1.5 &230 230 115 1.25 Vac, 0.298, 115 & 230 1 Vac, 0.198, 1150.75 & 230 Vac, 0.122, Vac, 0.0633, 0.5 115 & 230 Vac,0.25 0, 0 www.aimtec.com F 052.1e R3.R 115 & 230 0 Vac, 18.22, 2.5 0.0633 K() Tel: +1 514 620 2722 9 of 10 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMER120-CAZ up to 5A | AC-DC / DC-DC | LED Driver / Converter Output Current vs. Radj AMER120-36340CAZ (A) Output Current VS. Dimming-Resistance 115 & 230 115 & 230 Vac, 3.38, Vac, 1.663, 3.06 2.72 115 & 230 115 & 230 Vac, 1.008, 1152.38 & 230 Vac, 0.6663, 1152.04 & 230 Vac, 0.4578, 1150.3142, & 230 Vac, 1.7 1151.36 & 230 Vac, 0.21134, 115 1.02 & 230 Vac, 0.1337, Vac,0.68 0.0726, 115 & 230 0.34 Vac, 0, 0 115 & 230 0 Vac, 22.1, 3.4 0.0726 K() AMER120-24500CAZ (A) Output Current VS. Dimming-Resistance 115 & 230 Vac, 3.582, 115 &4.5 230 115 & 230 Vac, 1.723, 4 Vac, 115&1.017, &230 230 115 3.5 Vac, 0.669, 3 Vac, 115&0.463, &230 230 115 Vac,2.5 0.314, 2 Vac, 0.197, 115 & 230 230 1151.5 & Vac, 0.143, Vac, 0.0736,1 115 & 230 Vac, 34.31, 50 0.5 (K) NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec's standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052.1e R3.R Tel: +1 514 620 2722 10 of 10 Toll free: + 1 888 9 AIMTEC (924 6832) North America only