DOCUMENT No. : HSPPAR003D (Page 1/8) Pressure Sensor HSPPAR003D Data Sheet 1. ALPS product No. HSPPAR003D 2. Application This specifications applies to air pressure sensor. 3. General description This product is a pressure sensor using effect of piezo resistive bridge circuit formed on silicon diaphragm. Piezo resistance is changed according to strain by applying pressure to the diaphragm. Other feature of this sensor is small size and easy solder base mounting by ceramic package. Pb free and RoHS compliant. 4. Content of specifications 4-1. Electric specification Page 2, 3 4-2. Functional block diagram Page 3 4-3. Full view Page 4 Page 5 4-4. Soldering conditions (Recommendation) 4-5. Reliability specification Page 5, 6 4-6. Packing specification Page 7 5. Legal Disclaimer Page 8 HEAD OFFICE 1-7, YUKIGAYA-OTSUKA-MACHI, OTA-KU, TOKYO, 145-8501, JAPAN PHONE +81(3)3726-1211 FAX +81(3)3728-1741 NAGAOKA PLANT 1-3-5, HIGASHITAKAMI-MACHI, NAGAOKA-CITY, NIIGATA-PREF, 940-0006, JAPAN PHONE +81 258-24-4111 FAX +81 258-24-4110 This specification is subject to change without notice. 11 10 76548293 (Page 2/8 ) 4-1. Electrical specifications Item Symbol Absolute Maximum Ratings supply current Pmax Max load pressure Tstg Storage temperature ESD HBM ESD Operating conditions Classify of Pressure Supply current Range of measurement pressure Operating temperature Non Linearity min. Specification Typ. max. [mA] - - 3 [kPa] 26 - 300 [deg] -40 - +150 [V] 1000 Notes [-] Absolute Icc [mA] 0.55 Popr [kPa] 50 Topr [deg] -20 - +85 [kohms] 4.0 5.5 7.0 [mV] 39.0 44.0 49.0 50--110kPa [mV] 73.0 79.0 85.0 110kPa [mV] --- (72.6) --- 101.3kPa [%FS] -2.0 3.0 8.0 110kPa 85 [%FS] -2.0 3.0 8.0 110kPa -20 TCOV_50H [%FS] -3.0 1.0 6.0 50kPa 85 TCOV_50L [%FS] -2.5 1.5 6.5 50kPa -20 TCSV_H [%FS] -3.0 2.0 7.0 85 TCSV_L [%FS] -4.0 1.0 6.0 -20 NL [%FS] -1.0 0.0 1.0 Electrical specifications Imp Bridge Resistance FS Full Span Output @110kPa Vout(110) Output Voltage@110kPa @101.3kPa Vout(101.3) Output Voltage@101.3kPa TCOV_110H Temperature Characteristics of Offset Voltage TCOV_110L Temperature Characteristics of Span Voltage Unit. 110 (Page 3/8 ) *Definitions Bridge Resistance 0.55mA, 110kPa Full Span Output FS(25) = Vout(110KPa,25) - Vout(50kPa,25) Output Voltage Vout(110kPa) Temperature Characteristics of Offset Voltage TCOV_110H = ( Vout(110kPa, 85) - Vout(110kPa, 25) ) / FS(25) x 100 TCOV_110L = ( Vout(110kPa, -20) - Vout(110kPa, 25) ) / FS(25) x 100 TCOV_50H = ( Vout(50kPa, 85) - Vout(50kPa, 25) ) / FS(25) x 100 TCOV_50L = ( Vout(50kPa, -20) - Vout(50kPa, 25) ) / FS(25) x 100 Temperature Characteristics of Span Voltage TCSV_H = ( FS(85) - FS(25) ) / FS(25) x 100 TCSV_L = ( FS(-20) - FS(25) ) / FS(25) x 100 Non Linearity NL = ( Vout(80kPa) - ( Vout(50kPa) + Vout(110kPa) ) /2 ) / FS x 100 4-2. Functional block diagram Icc *Vout = Output(+) - Output(-) 0 Output (+) Output (-) GND (Page 4/8 ) 4-3. Full view *Top view *Side view *Bottom view Index Mark *Front view *Pin-layout Pin No. GND Output(+) Icc Output(-) *Recommend foot print (Page 5/8 ) 4-4. Soldering conditions (Recommendation) Temperature Peak temperature Pre-Heat Heating Time 4-5. Reliability specifications (1) Pre-treatment of Reliability test parts 125x24Hr (8585%)x168Hr + 2 Baking 125x24HrMoisture absorption (8585%)x168Hr + Reflow2time Temperature() * ( Pre-treatment Reflow condition Pre heat 60180sec T min: 150 Tp : 260 T L : 220 tL : 60150sec Ts max: 200 Heating Time (Page 6/8 ) (2) No. 1 2 3 4 5 6 7 8 9 10 11 Test contents Item High Temp. Bias High Temp. Storage High Humidity and High Temp. Heat cycle Reflow Low Temp. storage Electrostatic Resistance(HBM) (HBM) Pressure cycle () Vibration Shock HAST Bias HAST( Test condition Test Time Qty Criterion 125Icc=0.55mA 1000Hr 22 *1 150 1000Hr 22 *1 8585%Icc=0.55mA 1000Hr 22 *1 -65150 100cycle 22 *1 JEDEC4 3 11 *1 -55 1000Hr 22 *1 100PF1.5k1kV --- 3 *1 400Pa50Pa 10000cycle 22 *1 --- 11 *1 --- 11 *1 50Hr 22 *1 202000Hz 20G4cycel 4min./cycel 1500G 0.5msec X Y Z5 13085%RH2atmIcc=0.55mA (3) Criterion FS sensitivity() <2.5%FS *1 Output voltage() 2.5%FS No.1, 3, 913 (1) (Page 7/8 ) 4-5. Packing specification (1) Package storage direction Emboss Tape Index Mark Direction of tape pull out Package (2) Direction of tape drawing out Barcode Label Direction of tape pull out (3) Taping 5. LEGAL DISCLAIMER 1. For the export of products which are controlled items subject to foreign and domestic export laws and regulations, you must obtain approval and/or follow the formalities of such laws and regulations. 2. Products must not be used for military and/or antisocial purposes such as terrorism, and shall not be supplied to any party intending to use the products for such purposes. 3. AV Unless provided otherwise, the products have been designed and manufactured for application to equipment and devices which are sold to end-users in the market, such as AV (audio visual) equipment, home electric equipment, office and commercial electronic equipment, information and communication equipment or amusement equipment. The products are not intended for use in, and must not be used for, any application of nuclear equipment, driving control equipment for aerospace or any other unauthorized use. With the exception of the above mentioned banned applications, for applications involving high levels of safety and liability such as medical equipment, burglar alarm equipment, disaster prevention equipment and undersea equipment, please contact an Alps sales representative and/or evaluate the total system on the applicability. Also, implement a fail-safe design, protection circuit, redundant circuit, malfunction protection and/or fire protection into the complete system for safety and reliability of the total system. 4. Before using products which were not specifically designed for use in automotive applications, please contact an Alps sales representative. ALPS ELECTRIC CO.,LTD. () () 11 10 67548293