Combo Sel Gdv.2for PDF 4/1/98 3:38 PM Page 1 Te k t r o n i x Measurement Solutions Combo Sel Gdv.2for PDF 4/1/98 3:38 PM Page 2 2 N e w T X - D M M TM Tr u e R M S D i g i t a l M u l t i m e t e r s Applications * Installation and Maintenance of Industrial and Communications Equipment * Preventive Maintenance Programs * Manufacturing Process Troubleshooting * Design Verification and Debug WSTRM - Optional PC Interface Package * WaveStarTM for Meters Software * Optically-Isolated PC Interface Cable provides communication between TX DMM and PC RS-232 port Made in USA Save Time and Money without Sacrificing Quality, Safety, or Ruggedness The TX-DMM family can save you valuable time in the field. Its extra large display with backlight can be viewed from across the room. Making measurements is quick and easy with an innovative single input, single knob location interface. Dual display shows more information in fewer steps -- make AC and DC measurements without changing the meter function. The TX-DMM family provides the features and performance you need in an affordable package. TX-DMM technology provides high accuracy, high resolution, and a wide measurement range as well as fast RMS settling time. Each meter comes in a re-usable clamshell case and includes a traceable calibration certificate. The TX3 adds a built-in digital thermometer and K-type thermocouple probe. Accessories Refer to pages 12 and 13 for the new ATL25 Adjustable Test Lead Set and other meter accessories. All Tektronix meters have a 3 year warranty. Combo Sel Gdv.2for PDF 4/1/98 3:39 PM Page 3 3 Store It Error-free data collection is crucial to preventive maintenance programs. Use the TX-DMM MEM function to store up to 30 measurements in the field. Download It Use WSTRM to automatically download measurements to your PC. Document It Track and document measurements using WaveStar for Meters software Data Logging Use a TX-DMM meter with the optional WSTRM and other Windows(R) applications. PC Interface Package for data logging of temperature (TX3 only), voltage, or current variations on critical circuit components. Specifications TX1 TX3 True RMS Yes Yes Backlit Display Display Counts (Selectable) AC,DC, and (AC+DC) Volts and Amps; Resistance, Continuity, Diode Test, Capacitance, Frequency, Duty Cycle Basic DC Volts Accuracy MIN/MAX/AVG/MAX-MIN Recording with Time Stamp Yes Yes 50,000 and 5,000 50,000 and 5,000 Yes Yes 0.07% + 1Ct 0.05% + 1Ct Yes Yes 1 ms Peak Hold Yes Yes Computer Calibrated with "Cal Date" Readout *Yes *Yes Dual Readout Yes Yes Simultaneous AC and DC Readout *Yes *Yes 50 Range with Automatic Lead Calibration *Yes *Yes Non-Volatile Memory Locations *10 *30 - *Probe Standard Temperature Measurement (K-Type) dBm and dB Readings - Yes 4-20 mA Process Loop with % Readout - *Yes Setup Menu with Custom Defaults Yes Yes Safety Certifications CE, UL, CSA CE, UL, CSA Safety Voltage Rating *1000 V - CATIII *1000 V - CATIII *Yes *Yes Traceable Calibration Certificate Standard *Feature unique to TX digital multimeters. Safe, easy access allows fast battery replacement without breaking the calibration seal. Rugged boot with Versa-StandTM provides a versatile hook-stand for convenient, hands-free operation anywhere. Combo Sel Gdv.2for PDF 4/1/98 3:39 PM Page 4 4 Digital Multimeters Specifications True RMS Backlit Display Display Counts (Selectable) AC,DC, and (AC+DC) Volts and Amps; Resistance, Continuity, Diode Test, Capacitance, Frequency Duty Cycle Basic DC Volts Accuracy (4000 Ct Mode) Temperature Measurement (K-Type) Probes Sold Separately MIN/MAX/AVG/MAX-MIN Recording with Time Stamp 1mS Peak Hold DMM912 DMM914 DMM916 Yes Yes Yes - - Yes 40,000 and 4,000 40,000 and 4,000 40,000 and 4,000 Yes Yes Yes -- Yes Yes 0.2% + 1Ct 0.1% + 1Ct 0.06% + 1Ct - Yes Yes No Time Stamp Yes Yes - - Yes *Yes *Yes *Yes Dual Readout -- Yes Yes dBm and dB Readings -- -- Yes Center/Zoom Analog Bar Graph -- *Yes *Yes HI/LO Limits -- *Yes *Yes Delta % Readout -- *Yes *Yes Setup Menu with Custom Defaults Yes Yes Yes Average Responding AC Readout Safety Certifications CE, UL, CSA CE, UL, CSA CE, UL, CSA 600 V - CATIII 1000 V - CATII 600 V - CATIII 1000 V - CATII 600 V - CATIII 1000 V - CATII DMM249 DMM254 DMM150 DMM157 Display Counts 3200 4000 3200 3200 True RMS Yes Yes -- -- 0.3% + 2 cts 0.1% + 2 cts 0.7% + 2 cts 0.5% + 2 cts AC Voltage Ranges 3 - 750 V 400 mV - 750 V 3 - 600 V 3 - 600 V DC Voltage Ranges 300 mV - 1000 V 400 mV - 1000 V 300 mV - 600 V 300 mV - 600 V DC Current Ranges 300 A - 20 A 4 mA - 10 A -- 300 A - 10 A AC Current Ranges 300 A - 20 A 4 mA - 10 A 300 A* 300 A - 10 A Resistance Ranges 300 - 30 M 400 - 40 M 300 - 30 M 200 - 20 M Capacitance Ranges -- 4 nF - 40 F -- 3 - 3000 F Frequency Ranges -- 100 Hz - 1 MHz -- -- Analog Bargraph Display Yes Yes Yes Yes Diode Test Yes Yes Yes Yes Dual Safety Voltage Ratings *Feature unique to DMM900 Specifications Basic DC Volts Accuracy Continuity Check Safety * With optional CMM150 clamp probe Accessories See pages 12 - 13 All Tektronix meters have a 3 year warranty. Yes Yes Yes Yes IEC, UL, CSA IEC, UL, CSA IEC, UL, CSA IEC, UL, CSA Combo Sel Gdv.2for PDF 4/1/98 3:39 PM Page 5 Clamp Meters, Digital Thermometers Specifications DCM320 DCM910 4000 4000 400 - 600 V -- Frequency 40 - 500 Hz -- Accuracy 1.20% + 5 cts -- 400 - 600 A 40 - 1000 A Frequency 50/60 Hz 40 - 400 Hz Accuracy 1.90% + 5 cts 1.90% + 8 cts Display Counts AC Voltage Ranges AC Current Ranges DC Current Ranges Accuracy Resistance Ranges Accuracy Frequency Ranges -- 400 - 1000 A -- 1.90% + 10 cts 4 - 40 k -- 2.0% + 9 cts -- -- 4 - 10 kHz Accuracy -- 0.50% + 3 cts Autoranging Yes Yes True RMS Yes Yes up to 2.5 up to 3 Crest Factor Continuity Beeper Hold Jaw Size (diameter) Yes (<100 ) -- Display Peak Hold 40 mm 51 mm Safety IEC, UL, CSA IEC, UL, CSA Transducer Transformer Hall Effect Specifications DTM900 DTM920 Thermocouples K J or K Channels 1 2 (0.2% + 1C) (0.1% + 0.7C) -- (0.3% + 2.2C) Accuracy (Single Input) Accuracy (T1-T2) Resolution DCM320 Features: * True RMS AC measurements * Autoranging Applications: * Troubleshoot plant electrical systems * Verify building power systems * Install electrical equipment DCM910 Features: * 1000 A rating for industrial measurements * Hall effect transducer provides accurate DC readings Applications: * Maintain industrial equipment * Troubleshoot adjustable speed drives * Install motor drives DTM900 Features: * Intuitive layout provides easy access to all functions * Maximum feature captures extreme measurements 0.1/1C 0.1/1C Temperature Range -50 to +1300C -200 to +1370C Measurement Hold Yes Yes Yes/No Yes/Yes Differential (T1-T2) -- Yes Autoranging -- Yes DTM920 Stopwatch -- Yes Features: 170 x 74 x 39 mm 170 x 74 x 39 mm 431 g* 431 g* Record Max/Min Dimensions (LxWxD) Weight * Includes 131 g holster Applications: * Food process monitoring * Verify heating in electronic components * Dual-channel and differential temperature measurements * Stopwatch easily tracks temperature measurements over time * Intuitive layout provides easy access to all functions Applications: * Monitoring process control equipment * Troubleshooting HVAC-R systems Accessories See pages 12 - 13 All Tektronix meters have a 3 year warranty. 5 Combo Sel Gdv.2for PDF 4/1/98 3:40 PM Page 6 Handheld Digital Oscilloscopes 6 Take floating measurements, not risks Using proprietary IsolatedChannelTM architecture, you can safely acquire both channels even when they are referenced to different or dynamically changing potentials. Both oscilloscope channels and DMM are independently isolated. Catch glitches Pulse trigger and a fast sample rate reveal glitches that go undetected with lower sample rates. See what really happens A fast update rate and Digital Real-Time acquisition keep pace with changes, delivering digital precision with an analog look. The TekScope(R) THS700 Series combines a Digital Real-Time oscilloscope with a true RMS digital multimeter in a rugged handheld package. Scope and meter modes operate simultaneously or independently on the same or separate signals. Features include: high resolution backlit display, cursors, voltage and resistance measurements, and storage of waveforms, data, and instrument setups. Specifications Bandwidth Sample Rate per Channel THS710A THS720A THS730A 60 MHz 100 MHz 200 MHz 250 MS/s 500 MS/s 1 GS/s Channels 2 2 2 Digitizers 2 2 2 Record Length 2500 points 2500 points 2500 points Glitch Capture 8 ns 8 ns 8 ns Isolated Channels Yes Yes Yes CE Marked Yes Yes Yes P6117 P6117 P6117 Standard 10X Probes (2) Triggering External, Video, and Pulse Width Meter Resolution 4000 counts, 3-3/4 digits Maximum Float Voltage 600 V RMS each channel DC Volts Yes Yes Yes Accessories True RMS AC Volts Yes Yes Yes * THS7HCA Hard Carrying Case * THS7BAT Battery * THS7CHG Battery Charger * WSTR31/WSTR31U WaveStarTM Electronic Lab Notebook Software Resistance Yes Yes Yes Diode Test Yes Yes Yes Continuity Check Yes Yes Yes Additional accessories See page 12 Compatible probes See pages 12 - 15 Combo Sel Gdv.2for PDF 4/1/98 3:40 PM Page 7 Safe Power Measurements The TekScope THS720P with IsolatedChannelTM architecture and built-in DMM is ideal for electric/power electronics applications. The THS720P has all of the THS720A features, plus power and harmonic measurement capabilities to test and verify operation of motors, transformers, power supplies, and the effects of harmonics. The THS720P has specialized triggering for PWM AC motors. Measure harmonic content Specifications THS720P The THS720P bar graph displays harmonic content of each of the harmonic frequencies including the fundamental (fundamental frequency from 30 - 450 Hz) up to the 31st. Bandwidth 100 MHz Power measurements made easy Sample Rate per Channel 500 MS/s Simply press MATH to display the statistics of the same signal shown above, including Power Factor and other power measurements. Number of Channels Digitizers 2 2 Record Length 2500 points Glitch Capture 8 ns Isolated Channels Yes CE Marked Yes Harmonics Yes Power Measurement and Statistics Yes Standard Probes (2) High Voltage P5102 Triggering External, Video, Pulse Width, Motor 7 Combo Sel Gdv.2for PDF 4/1/98 3:41 PM Page 8 Digital Real-Time Oscilloscopes 8 Multilingual menus and help Interface modules Display text in English, French, German, Italian, Japanese, Korean, Portuguese, Simplified Chinese, Spanish, and Traditional Chinese. Plug-in modules for printing, communications, and control. Includes WaveStarTM Lite software. * TDS2HM -- Centronics * TDS2CM -- Centronics, GPIB, RS-232-C * TDS2MM -- FFT/Measurements, Centronics, GPIB, RS-232-C The TDS 200 Digital Real-TimeTM oscilloscopes will change the way you think about low-cost oscilloscopes. Compare performance, portability, and value: autotriggering, zoom, automatic measurements, save and recall of waveforms and setups, math functions, and crisp liquid crystal display. Specifications TDS 210 TDS 220 Bandwidth 60 MHz 100 MHz Channels 2 2 1 GS/s 1 GS/s 5 ns/div - 5 s/div 5 ns/div - 5 s/div 3% 3% Max Sample Rate per Channel Sweep Speeds Vertical Accuracy Vertical Resolution Record Length Accessories Vertical Sensitivity * AC220 soft carrying case * RM200 rackmount kit Features Compatible probes See pages 13 - 15 The Huntron Tracker(R) TR210 works with oscilloscopes like the TDS 200 to simplify the troubleshooting of populated circuit boards in a power off condition, including CMOS and MOS circuits. The built-in pulse generator makes it possible to evaluate gate-fired devices such as SCRs, TRIACs, and opto-couplers. Specifications Test Frequencies Functions Compare-A-Trace Pulse Level DC Mode Pulse Mode Power Requirement Huntron Tracker TR210 50 - 60 Hz, 200 Hz, 2 kHz Range Selection, High Range Lockout 0.5 - 10 Hz 0-5V +DC or -DC +Pulse, -Pulse, or both 100 VAC, 115 VAC, 230 VAC; 47 - 63 Hz 8 bits 8 bits 2.5k points/channel 2.5k points/channel 10 mV/div - 5 V/div at full bandwidth, 2 mV/div - 5 mV/div at 20 MHz Automatic Measurements, 2 Reference Waveforms, Peak Detect, Autoset, Multi-Language User Interface, 5 Setup Memories, Two P6112 Probes, Certificate of Calibration Combo Sel Gdv.2for PDF 4/1/98 3:41 PM Page 9 9 FFT Acquisition modes Analyze signal harmonics; evaluate distortion and symmetry. Video and edge triggering with 4 acquisition modes: sample, envelope, average, and peak detect. The TDS 300 Digital Real-Time oscilloscopes offer a wide range of circuit design and test utilities, including FFT analysis. Store waveforms and setups in a wide range of formats and transfer files to your PC using the floppy disk drive or the optional communications interface. Specifications TDS 340A TDS 360 TDS 380 Bandwidth 100 MHz 200 MHz 400 MHz Sample Rate per Channel 500 MS/s 1 GS/s 2 GS/s Sweep Speeds 5 ns/div - 5 s/div 2.5 ns/div - 5 s/div 1 ns/div - 5 s/div Record Length 1k points/channel 1k points/channel 1k points/channel P6109B P6111B P6114B Standard Probes (2) Features TV Line & Field Trigger, Roll Mode, Autoset, Peak Detect, 21 Automatic Measurements, FFT, Disk Drive, Certificate of Calibration Option 14 RS-232, GPIB, VGA Monitor Output, Centronics-type Parallel Printer Port Optional WaveStarTM for Oscilloscopes Software Windows(R) 95/NT application allows you to capture, analyze, document, and control oscilloscope waveforms and measurements. WaveStar is compatible with all TDS and THS Series oscilloscopes with GPIB or RS-232 interfaces. * WSTRO -- WaveStar for Oscilloscopes, Windows 95/NT version * WSTROU -- Upgrade from WSTR31 to WSTRO * WSTR31 -- Windows 3.1 version Accessories * Soft-sided carrying case (016-1158-01) * Hard transit case (016-0792-01) * Deluxe transit case with retractable wheels and handle (016-1157-00) * Accessory pouch (016-1159-00) * Front cover (200-3232-01) * Rackmount kit (016-1166-00) Compatible probes See pages 13 - 15 Combo Sel Gdv.2for PDF 4/1/98 3:41 PM Page 10 10 Power Supplies Expect safe, reliable performance Specifications every time you turn on a Tektronix Output Type power supply. Proven design and Voltage Range top quality components set these PS2521G Triple Triple 0 - 6 V (one) 0 - 36 V (two) 0 - 6 V (one) 0 - 20 V (two) 3 A (6 V)/1.5 A (36 V) 5 A (6 V)/2.5 A (20 V) GPIB Programmable Yes Yes Yes Yes programmable models to meet your Front Panel Programmable design, test, or lab requirements. Over Voltage Protection Yes Yes Over Current Protection Yes Yes Serial, Parallel Independent Modes Yes Yes CPS250 PS280 Triple Triple 5V 2A 5V 3A 0 - 20 V 0.5 A 0 - 30 V 2A Variable Current Limiting Yes Yes Overload Indicator Yes -- Serial, Parallel Independent Modes -- Yes instruments apart from the competition. Choose from manual or Maximum Current PS2520G Output Type One Fixed Output/ Maximum Current Two Variable Output/ Maximum Current Combo Sel Gdv.2for PDF 4/1/98 3:42 PM Page 11 F u n c t i o n G e n e r a t o r s , F r e q u e n c y C o u n t e r, D i g i t a l M u l t i m e t e r Function Generator Specifications CFG253 CFG280 0.03 Hz - 3 MHz 0.01 Hz - 11 MHz Sine, Square, Triangle, TTL Pulse Sine, Square, Triangle, TTL Pulse Internal or External Sweep Yes Yes Built-In 100 MHz Counter -- Yes VFC (FM) Input -- Yes AM Input -- Yes, Ext. sinewave Sync Out Yes Yes Frequency Range Output Counter Specifications CMC251 Frequency Range Ch A 1 Hz - 100 MHz Frequency Range Ch B 80 MHz - 1.3 GHz Stability Sensitivity (RMS) 1 ppm 5 - 35 mV Period Yes Pulse Width Yes Totalize Yes DMM Specifications AC/DC Volts Ranges DC Volts Accuracy AC/DC Current Ranges CDM250 200 mV - 500 V 0.5% of rdg + 2% of full scale 200 A - 10 A Resistance Ranges 200 - 20 M Display 3-1/2 digit LED Overrange Indication 11 Yes Sony/Tektronix programmable arbitrary function generators output a wide variety of waveforms for design and manufacturing test. Specifications Independent Channels Frequency Range Arbitrary Waveform Sample Rate AFG310 AFG320 1 2 10 mHz - 16 MHz 16 MS/s Vertical Resolution 12 bits Waveform Memory 4 x 16k Output Level (50 ) Output Modes Output Waveforms Waveform Editing Software 50 mVP-P - 10 VP-P Continuous, Triggered, Burst Sine, Square, Triangle, Ramp, Pulse, DC, Noise Yes Linear/Log Sweep Yes AM/FM/FSK Modulation Yes GPIB Programmable Yes Combo Sel Gdv.2for PDF 4/1/98 3:42 PM Page 12 Accessories 12 Handheld Instrument Accessories Description ATLDX1 DMM100/200 DMM900 TX-DMM * * * Deluxe Lead Set DTM900 DCM320 THS700 * * ATL01 Standard DMM Test Leads * * * * * ATL21 Shielded Banana Plug Leads * * * * * ATL22 Test Lead Tips * * * * * ATL23 Sharp "IC" Test Lead Tips * * * * * ATL25 Adjustable Test Lead Set * * * * * ACL21 Alligator Clips * * * * * ACL22 Hook-tip Clips * * * * * ACL23 Wire Clamp Clips * * * * * ACL24 Jaw Clips * * * * * AC11 Soft Case * AC12 Large Soft Case AC13 Long Soft Case ATK01 Thermocouple Adapter ATP01 Temperature Probe A605 AC Current Probe, 500 A A621 AC Current Probe, 2,000 A A622 CMM150 * * * * * * * * * * * AC Current Probe, 100 A AC Current Clamp Probe, 300 A * * * * * * * * * * * * DMM150 only ACL21 ACL22 ACL23 ACL24 ATL22 NEW ! ATL25 ATL21 ATLDX1 CMM150 Combo Sel Gdv.2for PDF 4/1/98 3:43 PM Page 13 13 Probe/Scope Compatibility Probe Description TDS 200 TDS 300 THS700 Voltage Passive 1X P6101B P6101B P6101B Voltage Passive 10X P6112 P6109B P6111B P6114B P6117 P6119B* P6129B* High Voltage Passive 100X P5100 P5100 High Voltage Passive 1000X P6015A P6015A Voltage Passive SMD P6561A P6562A Specialty Logic P6408 P6408 Voltage Passive 1X/10X High Voltage Passive 10X AC13 P5102 Differential High Voltage AC12 AC11 P5200 P5200 ADA400A ADA400A Voltage Active Probe P6243S P6243S Current Measurement AC P6021 A621 P6021 A621 A605 (DMM) A621 (Scope) AM503S A622 AM503S A622 A622 (Scope) Differential (V) Current Measurement AC/DC ATP01 * Not CE Listed ATK01 Current Probes Specifications A605 A621 A622 Frequency Range 48 Hz to 1 kHz 5 Hz to 50 kHz DC to 100 kHz 500 A Peak 2000 A Peak 100 A Peak 300 A AC RMS 1 mV/A 1 mV/A 10 mV/A 100 mV/A 10 mV/A 100 mV/A 1 mV/0.1 A 30 mm (1.18 inch) 54 mm (2.13 inch) 11.8 mm (0.46 inch) 29 mm (1.14 inch) Shielded Banana BNC (BNC to Shielded Banana Adapter) BNC (BNC to Shielded Banana Adapter) DMM DMM, THS700 DMM, THS700 Maximum Input Current Output Maximum Conductor Diameter Connector Type Instrument Compatibility CMM150 A605 DMM150 A621 Current Probe Systems Specifications Bandwidth AM503S with A6302 Probe AM503S AM503S with A6303 Probe with A6304XL Probe 50 MHz* 15 MHz 2 MHz Maximum Continuous 20 A 100 A 500 A Peak Pulse 50 A 500 A 700 A Cable Length 2m 2m 8m * 100 MHz with optional A6312 Probe A622 Combo Sel Gdv.2for PDF 4/1/98 3:43 PM Page 14 Accessories 14 Active Probes Specifications Attenuation Bandwidth at -3 dB 1103 DC Offset Range System Input Resistance P6202A P6205 P6243* 10X/100X 10X 10X 1 GHz 900 MHz 500 MHz 750 MHz 5.6/56/200 V 55/200 V N/A N/A 100 k/1 M/1 M 10 M 1 M 1 M Typical Input C 3/1.5/1.5 pF 2/2 pF 2 pF < 1 pF Maximum Voltage 100/200 V 200/200 V 40 V 40 V 1101A 1101A 1103 1103 Probe Power Supply for 2205, TAS, and TDS 300 Scopes P6243 P6201 1X/10X/100X * P6243S includes two P6243 probes and one 1103 TEKPROBE(R) Power Supply. Probe Power Supplies Probe power supplies provide external power to probes when the oscilloscope does not. Specifications P5102 Probes 1103 1101A ADA400A, P5205, P6204, P6205, P6217, P6243, P6245 P6201, P6202A Probe Inputs 2 2 BNC Outputs 2 -- TEKPROBETM Interface Voltage Offset Switches Potentiometers Overload Protection Scope Compatibility Yes -- 2 -- 2 -- Yes Yes TDS 200, TDS 300, 2205, TAS 200 Passive Voltage Probes Specifications P6101B P6103B P6109B P6111B P6112 P6114B Bandwidth (MHz) 15 60 100 200 100 400 Attenuation 1X 10X 10X 10X 10X 10X Compensation Range N/A 15 - 35 pF 15 - 35 pF 15 - 35 pF 15 - 35 pF 15 - 35 pF Readout -- -- Yes Yes -- Yes Scope Compatibility All All TDS 300/TDS 400A TDS 360 TDS 200 TDS 380 * Not CE Listed P6015A P6112 Combo Sel Gdv.2for PDF 4/1/98 3:44 PM Page 15 15 Passive High Voltage Probes Specifications Attenuation Bandwidth Loading DC Maximum Length Comp. Range Readout P5100 P5102 P6015A 100X 10X 1000X 250 MHz 100 MHz 75 MHz 10 M/2.75 pF 5 M/11.2 pF 100 M/3 pF 2.5 kV 1.0 kV 20 kV 10 ft ( 3 m) 2 m ( 6.6 ft) 10 ft ( 3 m) 7 - 30 pF 24 - 28 pF 7 - 49 pF Yes No Option 1R P5200 P5205 ADA400A 50X/500X 50X/500X N/A N/A N/A 0.1X, 1X, 10X, 100X P5200 Active Differential Probes Specifications Attenuation Gain Bandwidth 25 MHz 100 MHz 1 MHz Bandwidth Filters N/A N/A 100 Hz, 3 kHz, 100 kHz Maximum Input Differential Voltage (VDM) 1300 V (DC + peak AC) 1300 V (DC + peak AC) 80 V @ 0.1X, 10 V @ 1X, 1 V @ 10X, 100 mV @ 100X 1000 V (DC + peak AC) 1000 V (DC + peak AC) 40 V @ 0.1X, 40 V @ 1X, 10 V @ 10X, 10 V @ 100X Input R (each input) 4 M 4 M 1 M, selectable mode Input C (each input) 7 pF 7 pF 55 pF 80 dB (10,000:1) @ 60 Hz; 50 dB (1,000:1) @ 100 kHz 50 dB (1,000:1) @ 1 MHz > 100 dB (100,000:1) @ 10 kHz; > 90 dB (30,000:1) @ 100 kHz Maximum Input Voltage to Ground (VCM) CMRR (Common Mode Rejection Ratio) Cable Length Operating Power P6117 1.8 m (6 ft) 1.8 m (6 ft) 2 m (6.6 ft) AC power adapter included TEKPROBE power interface TEKPROBE power interface P6119B* P6129B* P6561A P5205 YT5100* YT5060* 200 10/100 10/100 200 100 60 10X 1X/10X 1X/10X 10X 1X/10X 1X/10X 15 - 35 pF 15 - 35 pF 15 - 35 pF 15 - 35 pF 20 - 45 pF 20 - 45 pF -- -- Yes Yes -- -- THS700 TDS 300/TAS 200 All TDS 300/TAS 400 All All P6117 Combo Sel Gdv.2for PDF 4/1/98 3:37 PM Page 16 For further information, contact Tektronix: ASEAN Countries (65) 356-3900 Australia & New Zealand 61 (2) 888-7066 Austria, Eastern Europe, & Middle East +43 2236 8092 0 Belgium +32 (2) 715.89.70 Brazil and South America 55 (11) 3741-8360 Canada 1 (800) 661-5625 Denmark +45 (44) 850 700 Finland +358 (9) 4783 400 France & North Africa +33 1 69 86 81 81 Japan (Sony/Tektronix Corporation) 81 (3) 3448-3111 Mexico, Central America, & Caribbean 52 (5) 666-6333 The Netherlands +31 23 56 95555 Norway +47 22 07 07 00 People's Republic of China 86 (10) 6235 1230 Republic of Korea 82 (2) 528-5299 South Africa (2711) 651-5222 Spain & Portugal +34 (1) 372 6000 Sweden +46 (8) 629 6503 Switzerland Germany +49 (221) 94 77 400 +41 (41) 729 36 40 Contents Digital Multimeters . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Hong Kong (852) 2585-6688 Taiwan 886 (2) 722-9622 India (91) 80-2275577 United Kingdom & Eire +44 (0) 1628 403400 Italy +39 (2) 25086 501 Digital Thermometers . . . . . . . . . . . . . . . . . . . . . . . . . 5 Handheld Digital Oscilloscopes .................6 Bench Oscilloscopes . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Bench Instruments . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 USA 1 (800) 426-2200 From other areas, contact: Tektronix, Inc. Export Sales P.O. Box 500, M/S 50-255 Beaverton, Oregon 97077-0001 USA 1 (503) 627-6877 Visit our World Wide Web site: http://www.tek.com Copyright (c) 1998, Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX, TEK, TEKPROBE, and TekScope are registered trademarks and TX-DMM, Versa-Stand, Digital Real-Time, WaveStar, and IsolatedChannel are trademarks of Tektronix, Inc. All other tradenames referenced are the service marks, trademarks, or registered trademarks of their respective companies. 5/98 WCI 3MW-10858-3