Oiltight Switches & Pilot Devices
ø30mm - TWTD Series
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-167
A4
Switches & Pilot Devices
Specifications
Conforming to Standards EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14
Approvals
CSA:
pushbuttons and selector switches: A600
pilot lights and illuminated pushbuttons, direct supply
pilot lights and illuminated pushbuttons with integral transformer
(100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
UL:
pushbuttons and selector switches: A600
pilot lights and illuminated pushbuttons, direct supply
pilot lights and illuminated pushbuttons with integral transformer
(100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
TÜV:
pushbuttons and selector switches: A600=P600 (NO, NC)/Q600 (NO-EM, NC-LB)
pilot lights and illuminated pushbuttons, direct supply
pilot lights and illuminated pushbuttons with integral transformer
(100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V)
Operating Temperature
Operation: –25 to +50°C (without freezing)
Storage: –40 to +70°C (without freezing)
Vibration Resistance
10 to 55Hz, 98m/sec
2
(10g) conforming to IEC6068-2-6
Shock Resistance
980m/sec
2
(100g) conforming to IEC6068-2-7
Electric Shock Protection
Class 0 conforming to IEC60536
Degree of Protection
IP65 (from front of the panel)
(conforming to IEC60529)
IP54 (key switches)
NEMA 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13
(conforming to NEMA ICS6-110)
Mechanical Life
Momentary pushbuttons: 5,000,000 (900 operations per hour)
All other switches: 500,000
Pollution Degree
(conforming to IEC60947-1)
3 for switches not using a transformer
2 for switches using a transformer
Mechanical-Electrical Specifications
Rated Operational Characteristics
AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC-LB)
DC-13: P600 or Ue = 125V, le = 1.1A (NO, NC)
DC-13: Q600 or Ue = 125V, le = 0.9A (NO-EM, NC-LB)
Rated Insulation Voltage
600V
Rated Switching Over-Voltage
Less than 4kV, conforming to IEC60947-1
Rated Impulse Withstanding Voltage
4kV for contact circuit
2.5kV for lamp circuit
Rated Thermal Current
10 Amp
Minimum Switching Capacity
5 mA at 3V AC/DC
Contact Operation
Slow break NC or NO, self-cleaning
Operating Force
Flush and extended pushbuttons—with 1NO or 1NC contact: 6.2±2N (momentary),
7.0±2N (maintained)
Additional contacts—1NO or 1NC: +3.2N (momentary), + 3.3N (maintained)
Terminal Referencing
Conforming to CENELEC EN50005
Recommended Terminal Torque
0.8 N m (7.1 in lb.)
External Short-Circuit Protection
10A 250V fuse conforming to IEC60269-1
Applicable Wire Size
Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG
Contact Resistance
Initial contact resistance of 50m
Ω
or less
Contact Gap
4mm (NO and NC)
2mm (NO-EM and NC-LB)
Lamp Ratings
Incandescent: 1 W
LEDs: 6, 12, 24V: 20mA / 120, 240V: 10mA
Maximum Inrush Current
40 A (40 msec)
Contact Material
Silver
Contact Ratings
Contact Ratings by Utilization Category IEC 60947-5-1 AC-15 (A600)
DC-13 (P600)
Contact Ratings by Utilization Category
Operational Voltage 24V 48V 50V 110V 220V 440V
Operation
Current
AC
50/60
Hz
AC-12 Control of resistive loads & solid state loads 10A
—
10A 10A 6A 2A
AC-15 Control of electromagnetic loads (> 72VA) 10A
—
7A 5A 3A 1A
DC DC-12 Control of resistive loads & solid state loads 8A 5A
—
2.2A 1.1A
—
DC-13 Control of electromagnets 5A 2A
—
1.1A 0.6A
—
File No. LR48366
UL Listed
Ref. No. 117617MC
File No. E70646