Libertyville, IL (847) 680-7400
B
General Purpose RFI Power Line Filters
General Purpose for High Impedance
Loads at Low Cost
UL Recognized
CSA Certified
VDE Approved
B Series
The B series RFI power line filters are general purpose
common-mode filters effectively providing RFI control
of line-to-ground noise in a small size at low cost.
These filters are designed to meet a wide variety of
electronic and electrical applications and are available
in a broad selection of current ratings and termination
styles. The EB models meet the very low leakage current
requirements of VDE portable equipment, and (120 Volt)
UL544 nonpatient medical equipment.
Electrical Schematic
Specifications
Maximum leakage current,
each line-to-ground
@ 120 VAC 60 Hz:.4 mA.21 mA
@ 250 VAC 50 Hz:.7 mA.36 mA
Hipot rating (one minute):
line-to-ground2250 VDC
line-to-line1450 VDC
Operating frequency:50/60 Hz
Rated voltage:120/250 VAC
Rated current:@ 120 VAC@ 250 VAC
1VB/1EB1A1A
2VB/2EB2A2A
3VB/3EB3A3A
5VB/5EB5A5A
10VB/10EB10A8A
10VB610A8A
20VB/20EB20A16A
30VB630A25A
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
CurrentFrequency-MHz
Rating.15.5151030
VB Models
1A, 3A153038505050
2A, 5A, 10A, 20A, 30A72025404548
EB Models
1A, 3A152935454548
2A, 5A, 10A, 20A71923343742
Resistor location for reference only.
BSeries
VB1/EB1VB3/EB3
10VB6/20VB6
VB ModelsEB
Models