Product Brochure Eaton ePDU G3 Basic and Metered Input Eaton's third-generation technology for power distribution The new Eaton(R) ePDU(R) G3 platform provides best-in-class power distribution, enabling data center and information technology (IT) managers to effectively monitor and manage their rack environments. Featuring Eaton's third-generation (G3) ePDU technology, ePDU G3 is easy to install and reduces operating costs while increasing reliability. With a host of unique and state-of-the-art features for both Basic and Metered Input ePDUs, ePDU G3 sets the standard for power management in a wide range of key applications. ePDU G3 key technology features Basic (BA) Metered Input (MI) * * IEC outlet grip plug retention * 1% billing grade accuracy * * Color-coded outlet sections Advanced LCD pixel display * Hot-swap meter * Low-profile form factor * * High operating temperature * * * Daisy chain of IP addresses Ease of installation * * Key applications Outlet grip plug retention Designed for IT environments, ePDU G3 is available in a variety of plug and outlet configurations, including both 120 and 200240 volt configurations. Power distribution is needed in racks to properly connect servers, switches and other IT equipment. Eaton's new patented IEC outlet grip secures plugs in place with a lever actuated grip that's integrated into each outlet. Once the levers click into the grip position, the plugs are secured from accidental disconnect due to bumps or vibrations. Unlike competitor solutions, the new outlet grip eliminates the need for special power cords that can increase purchase prices by $200 to $300. Small / medium business * 120V and lower kVA options * Economical Basic or Metered Input * Local pixel LCD display for onsite management Enterprise data centers * 208V three phase up to 17 kW for high density * Network monitoring of power usage and capacity * Variety of outlet configurations Billing grade accuracy 1% ePDU G3 provides one percent revenue-grade power monitoring for higher accuracy in department billing or collocation data centers. You are able to effectively measure power usage to all outlets and identify open capacity, resulting in full-power utilization. Utility rebate programs also require measurements that meet revenue-grade standards. 2 EATON Eaton ePDU G3 O is unlocked, + is grip engaged Color-coded outlet sections Each color-coded outlet section matches a corresponding circuit breaker in the new ePDU G3 models. This coding allows you to easily identify which circuit breaker feeds which outlets, and prevents unbalanced loading that could trip a breaker. Advanced LCD pixel display Hot-swap eNMC module The new ePDU G3 LCD pixel display simplifies local setup and trouble shooting. It also allows you to view voltage, power, total input, meters, LCD orientation and alarm history. In addition, the menu-driven display changes from blue to amber during an alarm situation, visually alerting you of a problem. Eaton's new hot-swap eNMC (ePDU Network Management and Control) module can be replaced without the need to power down your rack. As a result, you not only increase uptime, but also enhance serviceability and potentially save $200 to $500 on an unnecessary service call. ePDU G3's advanced LCD pixel display Hot-swap meter is able to be replaced without powering down the rack. Local buttons allow for easy menu navigation and simplify setup Low-profile form factor The width of the new ePDU G3 Basic and Metered Input ePDUs has been optimized for side mounting, resulting in zero interference into the rail space so you don't block hot-swap fans or power supplies. Some models feature low-profile circuit breakers to reduce interference when the ePDU is mounted with outlets facing the rail (center of the rack). ePDU G3 in Eaton S-Series rack ePDU G3 does not interfere with rail space ePDU G3 mounted at 90-degree angle EATON Eaton ePDU G3 3 High operating temperature All ePDU G3 models are fully functional in high operating temperature environments up to 140F (60C), resulting in reduced cooling costs. A higher operating temperature is needed for most modern hot-air containment solutions. Since ePDUs are located in the back of the rack where server exhaust can elevate temperatures to as high as 116F, based on ASHRAE's 80.6F maximum inlet temperature guidelines, it's important to have the right solution. Modern hot-air containment solution with ePDUs located in the hot air exhaust section Daisy chain four units from one IP address Eaton's new patented daisy chain is available on all network-connected ePDU G3 models. This feature allows four ePDUs to share the same network connection and IP address, resulting in a 75 percent reduction in network infrastructure costs, compared to competitor rack PDUs that require a dedicated IP address. Demonstrated cost difference based on two ePDUs per rack: 100 racks 200 racks 400 racks Dedicated IP address $40,000 $80,000 $160,000 Daisy chain method $10,000 $20,000 $40,000 Cost savings $30,000 $60,000 $120,000 Ease of installation * Patented clip feet allow for various mounting methods * Mounting buttons come pre-installed to reduce installation time * Double-sided aluminum buttons accommodate different variations of metal thickness * Optional side mounting button locations to mount ePDU G3s at a 90-degree rotation in the rack, preventing interference with hot-swap fans and power supplies Eaton patented clip feet Clip feet easily attach to ePDUs Mounting buttons come pre-installed on each ePDU G3 EATON Eaton ePDU G3 4 Light-weight aluminum chassis * Offers a 30 percent lighter-than-steel chassis, making each unit easier to install * Lower shipping costs compared to competitive models made from steel * Dissipates heat for better performance in high-density environments * Offers better electrical conductivity for improved electrical grounding Light-weight aluminum chassis can be easily held with one hand. Network management The advanced network capabilities of the ePDU G3 platform allow you to monitor multiple ePDUs through Eaton's power monitoring solutions. In addition, ePDU G3 has built-in support for third-party data center infrastructure management (DCIM) solutions by using SNMP v3 to communicate securely to each ePDU. Number of racks supported Software type Application Cost Web browser / email alerts 1-25 Embedded Web server Data closet or small network Included Eaton Intelligent Power Manager 1-200 Server based / Web interface Small-to-medium enterprise Free up to 10 nodes Third-party DCIM 50-1,000 Varies / SNMP data to third party Medium-to-large enterprise Varies Eaton Foreseer 100-1,000 Server based / Web interface Facility or large enterprise Varies by size Software Environmental monitoring The optional environmental monitoring probe connects to the serial port and enables you to collect temperature and humidity readings in the rack environment to monitor environmental data remotely. You can also monitor the status of two contact closure devices, such as door switches. Part Number EMP001 eaton.com/ePDUG3 EATON Eaton ePDU G3 5 ePDU G3 platform model selection guide Function Plug Breaker Max kW Cord (ft) Output receptacles Dimensions (H x W x D, in) EBA301-10 BA L15-20P (3) 20A 5.76 10 (30) C13, (6) C19 66.5 x 2.05 x 2.1 EBA311-10 BA L15-20P (3) 20A 5.76 10 (42) C13 69.5 x 2.05 x 2.1 EBA308-10 BA L21-20P None 5.76 10 (21) 5-20R, (6) L6-20R 66.5 x 2.05 x 2.1 EBA309-10 BA L21-20P None 5.76 10 (39) 5-20R 66.5 x 2.05 x 2.1 EBA302-10 BA L21-20P (3) 20A 5.76 10 (30) C13, (6) C19 66.5 x 2.05 x 2.1 EBA312-10 BA L21-20P (3) 20A 5.76 10 (42) C13 69.5 x 2.05 x 2.1 EBA303-10 BA L15-30P (3) 20A 8.64 10 (30) C13, (6) C19 66.5 x 2.05 x 2.1 EBA313-10 BA L15-30P (3) 20A 8.64 10 (42) C13 69.5 x 2.05 x 2.1 EBA310-10 BA L21-30P (3) 20A 8.64 10 (30) C13, (6) C19, (1) 5-20R 66.5 x 2.05 x 2.1 EBA304-10 BA L21-30P (3) 20A 8.64 10 (30) C13, (6) C19 66.5 x 2.05 x 2.1 EBA314-10 BA L21-30P (3) 20A 8.64 10 (42) C13 69.5 x 2.05 x 2.1 EBA305-06 BA CS8365 (3) 20A 12.48 6 (30) C13, (6) C19 66.5 x 2.05 x 2.1 EBA315-10 BA CS8365 (3) 20A 12.48 10 (42) C13 69.5 x 2.05 x 2.1 EBA300-06 BA CS8365 (2) 20A, (1) 30A 14.4 6 (24) C13, (4) C19, (2) L6-30P 66.5 x 2.05 x 2.1 ePDU G3 Metered Input models selection guide ePDU G3 Basic models selection guide Catalog Number EBA306-06 BA CS8365 (6) 20A 14.4 6 (21) C13, (12) C19 66.5 x 2.05 x 2.1 EBA307-06 BA IEC60309 460P9 (6) 20A 17.3 6 (21) C13, (12) C19 66.5 x 2.05 x 2.1 EMI100-10 MI 5-15P None 1.44 10 (24) 5-15R 66.5 x 2.05 x 2.1 EMI101-10 MI L5-20P (5-20P adapter) None 1.92 10 (24) 5-20R 66.5 x 2.05 x 2.1 EMI102-10 MI L5-30P (2) 20A 2.88 10 (30) 5-20R 66.5 x 2.05 x 2.1 EMI103-10 MI C20 (L6-20 adapter) None 3.84 10 (18) C13, (2) C19 35.5 x 2.05 x 2.1 EMI301-10 MI L15-20P (3) 20A 5.76 10 (30) C13, (6) C19 66.5 x 2.05 x 2.1 EMI311-10 MI L15-20P (3) 20A 5.76 10 (42) C13 69.5 x 2.05 x 2.1 EMI308-10 MI L21-20P None 5.76 10 (21) 5-20R, (6) L6-20R 66.5 x 2.05 x 2.1 EMI309-10 MI L21-20P None 5.76 10 (39) 5-20R 66.5 x 2.05 x 2.1 EMI318-10 MI L21-20P None 5.76 10 (30) C13, (6) C19, (3) 5-20R 66.5 x 2.05 x 2.1 EMI302-10 MI L21-20P (3) 20A 5.76 10 (30) C13, (6) C19 66.5 x 2.05 x 2.1 EMI312-10 MI L21-20P (3) 20A 5.76 10 (42) C13 69.5 x 2.05 x 2.1 EMI104-10 MI L6-30P (2) 20A 5.76 10 (36) C13, (6) C19 66.5 x 2.05 x 2.1 EMI303-10 MI L15-30P (3) 20A 8.64 10 (30) C13, (6) C19 66.5 x 2.05 x 2.1 EMI313-10 MI L15-30P (3) 20A 8.64 10 (42) C13 69.5 x 2.05 x 2.1 EMI310-10 MI L21-30P (3) 20A 8.64 10 (30) C13, (6) C19, (1) 5-20R 66.5 x 2.05 x 2.1 EMI304-10 MI L21-30P (3) 20A 8.64 10 (30) C13, (6) C19 66.5 x 2.05 x 2.1 EMI314-10 MI L21-30P (3) 20A 8.64 10 (42) C13 69.5 x 2.05 x 2.1 EMI305-06 MI CS8365 (3) 20A 12.48 6 (30) C13, (6) C19 66.5 x 2.05 x 2.1 EMI315-10 MI CS8365 (3) 20A 12.48 10 (42) C13 69.5 x 2.05 x 2.1 EMI300-06 MI CS8365 (2) 20A, (1) 30A 14.4 6 (24) C13, (4) C19, (2) L6-30R 66.5 x 2.05 x 2.1 EMI316-06 MI CS8365 (6) 20A 14.4 6 (9) C13, (12) C19 66.5 x 2.05 x 2.1 EMI317-06 MI IEC60309 460P9 (6) 20A 17.3 6 (9) C13, (12) C19 66.5 x 2.05 x 2.1 Eaton Electrical Sector 1000 Eaton Boulevard Cleveland, OH 44122 USA Eaton.com (c) 2014 Eaton All Rights Reserved Printed in USA BR155001EN January 2014 Eaton, Intelligent Power and ePDU are registered trademarks of Eaton. All other trademarks are property of their respective owners. For more information about the new ePDU G3 platform, visit Eaton.com/ePDUG3