2 of 11
RFSW2043
DS120718
7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical
support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com.
Absolute Maximum Ratings
Parameter Rating Unit
Drain Bias Voltage (VCTRL)-10V
DC
RF Input Power (Any State) +30 dBm
RF Output Power (ON State) +30 dBm
RF Output Power (OFF State) +21 dBm
Storage Temperature -55 to +150 °C
Operating Temperature -55 to +85 °C
ESD JESD22-A114 Human Body
Model (HBM)
Class 1A (All pads)
Parameter Specification Unit Condition
Min. Typ. Max.
Operating Frequency DC 20 GHz
Insertion Loss (0GHz to 5GHz) 1.5 2.2 dB ON State, All Temps
Insertion Loss (5GHz to 10GHz) 1.6 2.5 dB ON State, All Temps
Insertion Loss (10GHz to 15GHz) 1.8 2.8 dB ON State, All Temps
Insertion Loss (15GHz to 20GHz) 2.25 3.4 dB ON State, All Temps
Isolation (DC to 20GHz) 20 30 dB ON State, All Temps
Input Return Loss (DC to 20GHz) 10 16 dB ON State, All Temps
Output Return Loss (DC to 20GHz) 12 16 dB ON State, All Temps
Output Return Loss (DC to 20GHz) 15 22 dB OFF State, All Temps
OIP3 (2GHz to 20GHz) 35 46 dBm 100MHz spacing, 2dBm input, 25 °C
OIP2 (3GHz to 20GHz) 75 82 dBm 100MHz spacing, 2dBm input, 25 °C
Switching Speed 21 25 ns 50% control to 90% RF, All Temps
Control Current 41 55 µA Sum of all control lines, 25 °C
Control Voltage 0/-5 V
Caution! ESD sensitive device.
Exceeding any one or a combination of the Absolute Maximum Rating conditions may
cause permanent damage to the device. Extended application of Absolute Maximum
Rating conditions to the device may reduce device reliability. Specified typical perfor-
mance or functional operation of the device under Absolute Maximum Rating condi-
tions is not implied.
RoHS status based on EUDirective2002/95/EC (at time of this document revision).
The information in this publication is believed to be accurate and reliable. However, no
responsibility is assumed by RF Micro Devices, Inc. ("RFMD") for its use, nor for any
infringement of patents, or other rights of third parties, resulting from its use. No
license is granted by implication or otherwise under any patent or patent rights of
RFMD. RFMD reserves the right to change component circuitry, recommended appli-
cation circuitry and specifications at any time without prior notice.