KFA Power Entry Modules with Line Filter https://www.schurter.com /PG06 IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole, optional Voltage Selector (step switch) Screw-on mounting from front side Version with ground line choke without voltage selector Fuse drawer must be ordered separately (see accessories). Snap-in mounting from front side without voltage selector Fuse drawer must be ordered separately (see accessories). Screw-on mounting from rear side without voltage selector Flexible wire AWG18 Fuse drawer must be ordered separately (see accessories). C14 See below: Approvals and Compliances 70 C Description -Panel mount : Screw-on version from front or rear side, snap-in version from front side -4 Functions : Appliance Inlet Protection class I ,Fuseholder for fuse-links 5x20mm 1 or 2pole ,with or without voltage selector (step switch) ,Line filter in standard and medical version -V-Lock notch standard -Quick connect terminals or wires Unique Selling Proposition -Reduces noise on the ground wire -Interrupts ground loops -High asymmetrical attenuation -V-Lock cord retaining Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Allowable Operation Temperature Climatic Category IP-Protection Protection Class Terminal Panel Thickness S Material: Housing Characteristics -Rear side mounting for efficient costsaving assembly Suitable for assembly in metal plated plastic housings -All single elements are already wired -Plug removal necessary for fuse-link replacement -Suitable for use in medical equipment according to IEC/UL 60601-1 For applications according IEC/UL 62368-1 we recommend variants with bleed resistor Other versions on request -Capacity CX 100 nF References Alternative: version without line filter KEA Weblinks pdf data sheet, html datasheet, General Product Information, Approvals, Distributor-Stock-Check, Accessories, Detailed request for product, Microsite 1 - 10A @ Ta 40 C / 250VAC; 50Hz 1 - 10A @ Ta 40 C / 250VAC; 60Hz standard < 0.5mA (250V / 60Hz) medical < 5 A (250 V / 60 Hz) > 1.7kVDC between L-N > 2.7kVDC between L/N-PE Test voltage (2sec) -25C to 85C 25/085/21 acc. to IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Flexible wire AWG18, 150 mm Screw: max 8mm Mounting screw torque max 0.5Nm Snap-in: 0.8mm to 3mm Thermoplastic, black, UL 94V-0 Appliance inlet/-outlet Fuseholder Rated Power Acceptance @ Ta 23 C Power Acceptance @ Ta > 23C Voltage Selector Line Filter MTBF C14 acc. to IEC 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 C, 10A, Protection Class I 1 or 2 pole, Shocksafe category PC2 acc. to IEC 60127-6, for fuse-links 5 x 20mm 5 x 20: 2W (1 pole)/ 1.6W (2-pole) per pole Admissible power acceptance at higher ambient temperature see derating curves optional, step, 3 pos. Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details > 1'700'000h acc. to MIL-HB-217 F Approvals and Compliances Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER. EMC Products 1 KFA Power Entry Modules with Line Filter https://www.schurter.com /PG06 Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: KFA Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40004665 (FKE, FKF, FKV, FKW) UL Approvals UL UL File Number: E72928 (FKE, FKF, FKV, FKW) CQC Approvals CQC CQC Certificate Number: CQC18001206070 Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference Designed according to IEC 60127-6 Miniature fuses. Part 6. Fuse-holders for miniature fuse-links Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements Designed according to UL 498 Standard for Attachment Plugs and Receptacles Designed according to UL 1283 Electromagnetic interference filters Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters Design Standard Description Designed for applications acc. IEC/UL 62368-1 IEC 62368-1 includes the basic requirements for safety of audio, video, information technology and office equipment. Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance Designed for applications acc. IEC 60335-1 Safety of electrical appliances for household and similar purposes. Meets the requirements for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC 60695-2-11 or -12 & -13. Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863 China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. SCHURTER AG V-Lock system are based on a matching plug-dose combination. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. White Paper Glow wire test SCHURTER AG Meets the requirements of IEC 60335-1 for appliances in unattended use. This includes the enhanced requirements of glow wire tests acc. to IEC 60695-2-11 or -12 &-13. Medical Equipment SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1 Product standards Product standards that are referenced Organization Application standards Application standards where the product can be used Organization Compliances The product complies with following Guide Lines Identification 2 EMC Products KFA Power Entry Modules with Line Filter https://www.schurter.com /PG06 Dimensions [mm] Filter with voltage selector 2.8 29 0.3 o 6.3x90 44 230 36 27.2 R3.1 M3/o3.6 o 3.2 6.3x0.8** 4.8x0.8* 36 0.15 R6 0 R4.5 R3 -0.2 31.2 56 34 69.2 +0.3 33 0 4.7 Screw-on mounting from rear side R4 30 +0.20 36 0.15 3.6 32.8 x 28.5 36.5 2.65 9.6 31.2 R4 M3 34 2.2 R5 34.3 0 27.2 R 2.5 9.5 4.2 46.8 36 30.3 +0.20 0 R4 60.5 44.3 Snap-in mounting 0.8 - 3 33 max. (27.4) 37 max. (28.8) .1 0 R3 0.15 29.35 + 0.00 0.15 33 + 0.00 37 max. R4 .1 32.8 5 46 9.5 (31.4) 60.5 EMC Products 3 KFA Power Entry Modules with Line Filter https://www.schurter.com /PG06 Screw-on mounting from front side with ground line choke 36 0.15 44 R5 O 3.25 R4 33 0.3 0 M3 x 0.5 31.2 34 O 6.3 0 27.2 9.5 36 R3 -0.2 29 0.3 5 56 70.5 Screw-on mounting from front side 36 0.15 44 R5 O 3.25 R4 27.2 36 33 0.3 0 M3 x 0.5 31.2 34 O 6.3 0 9.5 29 0.3 5 46 R3 -0.2 60.5 Technical Data of Filter-Components Rated Current [A] 4 Filter-Type Inductance L1/ L2 [mH] Inductance L3 [mH] Capacitance CX [nF] Capacitance CY [nF] R [M] 1 Standard version 2 x 10 - 68 2.2 - 2 Standard version 2x4 - 68 2.2 - 4 Standard version 2 x 1.5 - 68 2.2 - 6 Standard version 2 x 0.8 - 68 2.2 - 10 Standard version 2 x 0.3 - 68 2.2 - 1 Standard Version with Ground Line Choke 2 x 10 0.6 100 2.2 - 2 Standard Version with Ground Line Choke 2x4 0.6 100 2.2 - 4 Standard Version with Ground Line Choke 2 x 1.5 0.6 100 2.2 - 6 Standard Version with Ground Line Choke 2 x 0.8 0.6 100 2.2 - 10 Standard Version with Ground Line Choke 2 x 0.3 0.15 100 2.2 - 1 Medical Version (M5) 2 x 10 - 68 - 1 2 Medical Version (M5) 2x4 - 68 - 1 4 Medical Version (M5) 2 x 1.5 - 68 - 1 6 Medical Version (M5) 2 x 0.8 - 68 - 1 10 Medical Version (M5) 2 x 0.3 - 68 - 1 1 Medical Version (M80) 2 x 10 - 68 0.47 1 2 Medical Version (M80) 2x4 - 68 0.47 1 4 Medical Version (M80) 2 x 1.5 - 68 0.47 1 6 Medical Version (M80) 2 x 0.8 - 68 0.47 1 EMC Products KFA Power Entry Modules with Line Filter https://www.schurter.com /PG06 Rated Current [A] Filter-Type Inductance L1/ L2 [mH] Inductance L3 [mH] Capacitance CX [nF] Capacitance CY [nF] R [M] 10 Medical Version (M80) 2 x 0.3 - 68 0.47 1 1 Medical Version (M5) with Ground Line Choke 2 x 10 0.6 100 - 1 2 Medical Version (M5) with Ground Line Choke 2x4 0.6 100 - 1 4 Medical Version (M5) with Ground Line Choke 2 x 1.5 0.6 100 - 1 6 Medical Version (M5) with Ground Line Choke 2 x 0.8 0.6 100 - 1 10 Medical Version (M5) with Ground Line Choke 2 x 0.3 0.15 100 - 1 Diagrams Standard version with voltage selector Standard version without voltage selector 3 2 1 X) L L1 1) F1 Cy PE Cx L2 N Cy L 2) F2 L1 Cy PE PE' X) L' F1 1) x) external connection to be made by the customer Cx F2 N 5 Medical Version (M5) with voltage selector L2 Cy L1 1) PE' PE N' Cx F1 2) PE' R L2 N 1) Line 2) Load 3 2 1 X) L 2) F2 X) 5 x) external connection to be made by the customer 1) Line 2) Load 1) Line 2) Load Medical Version (M5) without voltage selector L L' F1 1) L1 PE L1 1) PE' PE Cy Cx L2 N 1) Line 2) Load F1 R L2 N' Medical Version (M80) without voltage selector X) L 2) R Cx F2 N Medical Version (M80) with voltage selector Cy 3 2 1 L 2) PE' X) F2 1) PE N 5 x) external connection to be made by the customer L' F1 F2 L1 Cx Cy R L2 Cy 2) PE' N' 1) Line 2) Load 1) Line 2) Load Standard version with ground line choke L L' F1 1) Medical Version (M5) with ground line choke 2) Cy PE L2 Cy L' F1 1) L1 PE PE' Cx F2 N L L1 N' Cx F2 N Medical Version (M80) with ground line choke PE' R L 2) 1) PE L2 N' N L3 L3 1) Line 2) Load 1) Line 2) Load L' F1 F2 L1 Cx 2) Cy R L2 PE' Cy N' L3 1) Line 2) Load Derating Curves 2-pole 2.0 1.5 I = 1.0 In I = 0.7 In 1.0 I = << In 0.5 0.0 0 20 40 60 80 100 Ambient air temperature Ta C Admissible power acceptance in Watt Admissible power acceptance in Watt 1-pole 1.6 1.4 1.2 I = 1.0 In 1.0 0.8 I = 0.7 In 0.6 I = << In 0.4 0.2 0.0 0 20 40 60 80 100 Ambient air temperature Ta C EMC Products 5 KFA Power Entry Modules with Line Filter https://www.schurter.com /PG06 Attenuation Loss - - - - 50 differential mode _____ 50 common mode Standard version 1A 2A 4A 6A 2A 4A 6A 2A 4A 6A 10 A Medical version (M5) 1A 10 A Medical version (M80) 1A 10 A 6 EMC Products KFA Power Entry Modules with Line Filter https://www.schurter.com /PG06 Standard version with ground line choke 1A 2A 4A 6A 4A 6A 10 A Medical Version (M5) with ground line choke 1A 2A 10 A All Variants Rated Current [A] Filter-Type Panel mounting Mounting side Fuseholder Terminal 1 Standard version Snap-in Front Side 1-pole Quick connect terminals 6.3 x 0.8 mm - 4301.6011 1 Standard version Snap-in Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.6001 2 Standard version Snap-in Front Side 1-pole Quick connect terminals 6.3 x 0.8 mm - 4301.6012 2 Standard version Snap-in Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.6002 4 Standard version Snap-in Front Side 1-pole Quick connect terminals 6.3 x 0.8 mm - 4301.6013 4 Standard version Snap-in Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.6003 6 Standard version Snap-in Front Side 1-pole Quick connect terminals 6.3 x 0.8 mm - 4301.6014 6 Standard version Snap-in Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.6004 10 Standard version Snap-in Front Side 1-pole Quick connect terminals 6.3 x 0.8 mm - 4301.6015 EMC Products Voltage Selector Order Number 7 KFA Rated Current [A] Power Entry Modules with Line Filter https://www.schurter.com /PG06 Filter-Type Panel mounting Mounting side Fuseholder Terminal Voltage Selector Order Number 10 Standard version Snap-in Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.6005 1 Standard version Screw Front Side 1-pole Quick connect terminals 6.3 x 0.8 mm - 4301.5011 1 Standard version Screw Front Side 1-pole Quick connect terminals 6.3 x 0.8 mm 3 pos. 4301.5051 1 Standard version Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.5001 1 Standard version Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm 3 pos. 4301.5041 1 Standard version Screw Rear Side 1-pole Flexible wire AWG18 - 4301.7311 1 Standard version Screw Rear Side 2-pole Flexible wire AWG18 - 4301.7301 1 Standard version Screw Rear Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.7001 2 Standard version Screw Front Side 1-pole Quick connect terminals 6.3 x 0.8 mm - 4301.5012 2 Standard version Screw Front Side 1-pole Quick connect terminals 6.3 x 0.8 mm 3 pos. 4301.5052 2 Standard version Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.5002 2 Standard version Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm 3 pos. 4301.5042 2 Standard version Screw Rear Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.7002 4 Standard version Screw Front Side 1-pole Quick connect terminals 6.3 x 0.8 mm - 4301.5013 4 Standard version Screw Front Side 1-pole Quick connect terminals 6.3 x 0.8 mm 3 pos. 4301.5053 4 Standard version Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.5003 4 Standard version Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm 3 pos. 4301.5043 4 Standard version Screw Rear Side 1-pole Quick connect terminals 6.3 x 0.8 mm - 4301.7013 4 Standard version Screw Rear Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.7003 6 Standard version Screw Front Side 1-pole Quick connect terminals 6.3 x 0.8 mm - 4301.5014 6 Standard version Screw Front Side 1-pole Quick connect terminals 6.3 x 0.8 mm 3 pos. 4301.5054 6 Standard version Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.5004 6 Standard version Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm 3 pos. 4301.5044 6 Standard version Screw Rear Side 1-pole Quick connect terminals 6.3 x 0.8 mm - 4301.7014 6 Standard version Screw Rear Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.7004 10 Standard version Screw Front Side 1-pole Quick connect terminals 6.3 x 0.8 mm - 4301.5015 10 Standard version Screw Front Side 1-pole Quick connect terminals 6.3 x 0.8 mm 3 pos. 4301.5055 10 Standard version Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.5005 10 Standard version Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm 3 pos. 4301.5045 10 Standard version Screw Rear Side 1-pole Quick connect terminals 6.3 x 0.8 mm - 4301.7015 10 Standard version Screw Rear Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.7005 1 Standard Version with Ground Line Choke Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.8050 2 Standard Version with Ground Line Choke Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.8051 4 Standard Version with Ground Line Choke Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.8052 8 EMC Products KFA Power Entry Modules with Line Filter https://www.schurter.com /PG06 Rated Current [A] Filter-Type Panel mounting Mounting side Fuseholder Terminal Voltage Selector Order Number 6 Standard Version with Ground Line Choke Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.8053 10 Standard Version with Ground Line Choke Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.8054 1 Medical Version (M5) Snap-in Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.6201 2 Medical Version (M5) Snap-in Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.6203 4 Medical Version (M5) Snap-in Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.6205 6 Medical Version (M5) Snap-in Front Side 2-pole Flexible wire AWG18 - 4301.6307 6 Medical Version (M5) Snap-in Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.6207 1 Medical Version (M5) Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm 3 pos. 4301.5241 1 Medical Version (M5) Screw Rear Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.7201 2 Medical Version (M5) Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.5203 2 Medical Version (M5) Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm 3 pos. 4301.5243 2 Medical Version (M5) Screw Rear Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.7203 4 Medical Version (M5) Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.5205 4 Medical Version (M5) Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm 3 pos. 4301.5245 4 Medical Version (M5) Screw Rear Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.7205 6 Medical Version (M5) Screw Front Side 1-pole Quick connect terminals 6.3 x 0.8 mm - 4301.5217 6 Medical Version (M5) Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.5207 6 Medical Version (M5) Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm 3 pos. 4301.5247 6 Medical Version (M5) Screw Rear Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.7207 10 Medical Version (M5) Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.5209 10 Medical Version (M5) Screw Rear Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.7209 4 Medical Version (M80) Snap-in Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.6206 1 Medical Version (M80) Screw Rear Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.7202 2 Medical Version (M80) Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.5204 2 Medical Version (M80) Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm 3 pos. 4301.5244 2 Medical Version (M80) Screw Rear Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.7204 4 Medical Version (M80) Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.5206 4 Medical Version (M80) Screw Rear Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.7206 6 Medical Version (M80) Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.5208 6 Medical Version (M80) Screw Rear Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.7208 10 Medical Version (M80) Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.5200 10 Medical Version (M80) Screw Rear Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.7200 1 Medical Version (M5) with Ground Line Choke Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.8055 EMC Products 9 KFA Rated Current [A] Power Entry Modules with Line Filter https://www.schurter.com /PG06 Filter-Type Panel mounting Mounting side Fuseholder Terminal Voltage Selector 2 Medical Version (M5) with Ground Line Choke Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.8056 4 Medical Version (M5) with Ground Line Choke Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.8057 6 Medical Version (M5) with Ground Line Choke Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.8058 10 Medical Version (M5) with Ground Line Choke Screw Front Side 2-pole Quick connect terminals 6.3 x 0.8 mm - 4301.8059 Most Popular. Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER Wire length: 150 mm Packaging unit 10Pcs Required Accessory Description Fusedrawer 2 Fusedrawer fur Fuse Links 5x20 mm, with or without Voltage Selector Insert Fingergrip-Safe, 2-pole 3-104-672 Fingergrip, 2-pole, Voltage Selector, 110, 150, 220 4301.1014.01 Fingergrip, 2-pole, Voltage Selector, 120, 240 4301.1014.02 Fingergrip, 2-pole, Voltage Selector, 110, 220 4301.1014.03 ... Accessories Wire Harness Wire harness for SCHURTER products Assorted Covers Rear Cover 0859.0072 RC320 Rear Cover for Power Entry Module 10 EMC Products Order Number KFA Power Entry Modules with Line Filter https://www.schurter.com /PG06 Cord retaining kits Cord retaining strain relief Flat head, A 4700.0001 Countersunk, B 4700.0002 Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete 4787, Mounting: Screw-on mounting, Appliance Outlet: IEC Solder terminals, 10 A, Suitable for appliances with protection class I 4787 4788, Mounting: Snap-in version, Appliance Outlet: IEC Solder terminals or quick connect terminals, 10 A, Suitable for appliances with protection class I 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 Appliance Outlet further types to KFA Connector Overview complete 4782 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C13 4782 4785 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C13 4785 4012 Mounting: Power Supply Cord, 3 x 1 mm, Screw clamps, Connector: IEC C13 4012 4300-06 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06 4781 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C15 4781 Connector further types to KFA ... Mating Outlets/Connectors shuttered Connector Overview complete 4783 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C13 4783 Connector further types to KFA Power Cord Overview complete VAC13KS, Overview, V-Lock cord retaining, diverse Connector IEC C13, diverse, black VAC13KS Power Cord further types to KFA 14.10.2020 The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications. EMC Products 11