IX2127
4www.clare.com R02
1.4 Recommended Operating Conditions
1.5 General Conditions
Typical values are characteristic of the device at 25°C
and are the result of engineering evaluations. They are
provided for information purposes only and are not
part of the manufacturing testing requirements.
Unless otherwise noted, all electrical specifications
are listed for TA=25°C.
1.6 Electrical Characteristics
Unless otherwise specified, the test conditions are: VCC=VBS=12V; VCC, IN, FAULT, and Leakage voltages and
currents are referenced to COM; VB, HO, and CS voltages and currents are referenced to VS .
1.6.1 Power Supply Specifications
1.6.2 Gate Drive and Shutdown Specifications
* RGATE value must be 20 or greater.
Parameter Symbol Minimum Maximum Units
Logic Supply VCC 912
V
High Side Floating Supply VBVS+9 VS+12
High Side Offset Voltage VS-5 600
Logic Input Voltage VIN 0VCC
High Side Floating OutputVHO VSVB
Current Sense Signal Voltage VCS VSVS+5
FAULT Output Voltage VFLT 0VCC
Ambient Temperature T
A-40 +125 °C
Parameter Conditions Symbol Minimum Typical Maximum Units
Quiescent VCC Supply Current VIN=0V IQCC -280400
A
Quiescent VBS Supply Current VIN=0V IQBS - 500 1000
VBS UVLO Positive-Going Threshold -VBS_UV+ 6.8 7.7 8.6 V
VBS UVLO Negative-Going Threshold -VBS_UV- 6.3 7.2 8.1
Offset Supply Leakage Current VB=VS=600V ILKG --2
A
Parameter Conditions Symbol Minimum Typical Maximum Units
High Level Output Voltage, VB-VHO IHO=0A VOH --100
mV
Low Level Output Voltage, VHO IHO=0A VOL --100
Output Short Circuit Pulsed Current
VHO=0V, VIN=5V, PW<10s,
RGATE=20* (see Figure 1) IHO+ -200 -250 -
mA
VHO=12V, VIN=0V, PW<10s,
RGATE=20* (see Figure 1) IHO- 420 500 -
CS Input, Positive-Going Threshold VCC=9V to 12V VCS_TH+ 180 260 320 mV
“High” CS Bias Current VCS=3V ICS+ --1
A
VCS=0V ICS- ---1