Sep. 2000
φ3.5 ± 0.2 2.2 ± 0.2DEPTH
φ85 ± 0.2
+ 0
– 0.3
26 ± 0.5
φ120MAX
(φ127)
M3✕0.5 2.5DEPTH
0.4MIN 0.4MIN
(6.8)
φ134 ± 0.4
22.5° ± 0.5°
16-φ4.5+0.2
0
φ147 ± 0.4
φ85 ± 0.2
(4 )
A
A
A
kA
A2s
A/µs
V
V
A
A
kW
kW
W
W
°C
°C
kN
g
MITSUBISHI GATE COMMUTATED TURN-OFF THYRISTORS
FGC3500AX-120DS
HIGH POWER INVERTER USE
PRESS PACK TYPE
FGC3500AX-120DS OUTLINE DRAWING Dimensions in mm
3500
1800
1200
25
2.6 × 106
1000
10
21
1000
3500
10
120
200
6300
–20 ~ +125
–20 ~ +150
32 ~ 48
1500
Repetitive controllable on-state current
RMS on-state current
Average on-state current
Surge on-state current
Current-squared, time integration
Critical rate of rise of on-state current
Peak forward gate voltage
Peak reverse gate voltage
Peak forward gate current
Peak reverse gate current
Peak forward gate power dissipation
Peak reverse gate power dissipation
Average forward gate power dissipation
Average reverse gate power dissipation
Junction temperature
Storage temperature
Mounting force required
Weight
APPLICATION
Inverters, DC choppers, Induction heaters, DC to DC converters.
Symbol Parameter Conditions Ratings Unit
+ : VGK = –2V
ITQRM
IT(RMS)
IT(AV)
ITSM
I2t
diT/dt
VFGM
VRGM
IFGM
IRGM
PFGM
PRGM
PFG(AV)
PRG(AV)
Tj
Tstg—
—
●ITQRM
Repetitive controllable on-state current
.......... 3500A
●IT(AV) Average on-state current.................... 1200A
●VDRM
Repetitive peak off-state voltage
.................. 6000V
●Anode short type
VDM = 6000V, VD = 3600V, LC = 0.3µH, VRG = 20V
diGQ/dt = 6000A/µs, Tj = 25/125°C(see Fig. 1, 3)
Applied for all conduction angles
f = 60Hz, sinewave θ = 180°, Tf = 70°C
One half cycle at 60Hz, Tj = 125°C
VD = 3600V, IT = 3500A, IGM= 200A, Tj= 125°C
diG/dt = 100A/µs (see Fig. 1, 2)
(Recommended value 40kN)
Typical value
21
21
21
6000
6000
4800
3600
VRRM
VRSM
VR(DC)
VDRM
VDSM
VD(DC)
VLTDS
UnitSymbol Parameter V
V
V
V
V
V
V
Voltage class
Repetitive peak reverse voltage
Non-repetitive peak reverse voltage
DC reverse voltage
Repetitive peak off-state voltage
+
Non-repetitive peak off-state voltage
+
DC off-state voltage+
Long term DC stability voltage
+
MAXIMUM RATINGS
PRELIMINARY
Notice: This is not a final specification.
Some parametric limits are subject to change.