Page 2 HPR10XX REV C 9/98
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
ELECTRICAL SPECIFICA TIONS
Note: Other input to output voltages may be available. Please contact factory.
COMMON SPECIFICA TIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
* For demonstrated MTTF results reference Reliability Report HPR105
NOMINAL RATED RATED INPUT CURRENT REFLECTED
INPUT OUTPUT OUTPUT RIPPLE EFFICIENCY
VOLTAGE VOLTAGE CURRENT NO LOAD RATED LOAD CURRENT
MODEL (VDC) (VDC) (mA) (mA) (mA) (mAp-p) (%)
HPR1000 5 5 200 33 290 8 68
HPR1001 5 12 83 33 290 8 69
HPR1002 5 15 67 33 285 8 70
HPR1003 5 ±5 ±100 33 285 8 70
HPR1004 5 ±12 ±42 33 285 8 70
HPR1005 5 ±15 ±34 33 285 8 70
HPR1006 12 5 200 18 110 10 70
HPR1007 12 12 83 18 107 10 71
HPR1008 12 15 67 18 107 10 71
HPR1009 12 ±5 ±100 18 107 10 71
HPR1010 12 ±12 ±42 18 107 10 71
HPR1011 12 ±15 ±34 18 107 10 71
HPR1012 15 5 200 15 96 10 70
HPR1013 15 12 83 15 94 10 70
HPR1014 15 15 67 15 94 10 71
HPR1015
HPR1016 15 ±12 ±42 15 94 10 71
HPR1017 15 ±15 ±34 15 94 10 71
HPR1018 24 5 200 12 60 15 71
HPR1019 24 12 83 12 60 15 71
HPR1020 24 15 67 12 58 15 72
HPR1021 24 ±5 ±100 12 58 15 72
HPR1022 24 ±12 ±42 12 58 15 72
HPR1023 24 ±15 ±34 12 58 15 72
PARAMETER CONDITIONS MIN TYP MAX UNITS
INPUT
Voltage Range 4.5 5 5.5 VDC
10.8 12 13.2 VDC
13.5 15 16.5 VDC
21.6 24 26.4 VDC
Voltage Rise Time See Typical Performance Curves & Application Notes: "Capacitive Loading Ef fects on Start-Up of DC/DC Converters"
ISOLATION
Rated Voltage 1000 VDC
Test Voltage 60 Hz, 10 Seconds 1000 Vpk
Resistance 10 GΩ
Capacitance 25 100 pF
Leakage Current VISO= 240VAC, 60Hz 2 8.5 µArms
OUTPUT
Rated Power 1.0 W
Voltage Setpoint Accuracy Rated Load, Nominal VIN ±5 %
Ripple & Noise BW = DC to 10MHz 100 mVp-p
BW =10Hz to 2MHz 30 mVrms
Voltage 1mA Load, VOUT = 5V 7 VDC
1mA Load, VOUT = 12V 15 VDC
1mA Load, VOUT = 15V 18 VDC
Temperature Coefficent .01 %/Deg C
REGULATION
Line Regulation High Line to Low Line 1 %/%Vin
Load Regulation (5V out only) Rated Load to 1mA Load 10 %
Load Regulation (All other Models) Rated Load to 1mA Load 3 %
GENERAL
Switching Frequency 170 kHz
Frequency Change Over Line and Load 24 %
Package Weight 2g
MTTF per MIL-HDBK-217, Rev. E Circuit Stress Method
Ground Benign TA = +25°C 3.8 MHr
Fixed Ground TA = +35°C 1. 4 MHr
Naval Sheltered TA = +35°C 685 kHr
Airborne Uninhabited Fighter TA = +35°C 211 kHr
TEMPERATURE
Specification -25 +25 +65 °C
Storage -50 +110 °C