Sensing Band F03-16PE * SUS316 used for core and polyethylene used for sheath to ensure high resistance to both acidic and alkaline liquids. * Sensing Band Stickers that use the same material as the Sensing Band's insulating resin are available in 2 types: adhesivetape type and screw type. Ordering Information Name Model number Remarks Liquid Leakage Sensing Band F03-16PE --- Sensing Band Stickers F03-26PES F03-26PEN 30 Stickers per set 30 Stickers per set Specifications Sheath Polyethylene Core SUS316 stainless steel Ambient operating temperature 15 to 55qC Weight Approx. 16 g (1 m) Dimensions (Unit: mm) Sensing Band Appearance Structure 4 20 1.2 1.7 8 Materials: Electrodes: SUS316 stainless steel, Sheath: Polyethylene Sensing Band Stickers F03-26PEN (screws) F03-26PES (adhesive tape) Appearance Structure 19.2 32 5 3.0 13 13 Cut section 22 3.5 dia.** Material: Polyethylene Adhesive tape (See note.) Material: Polyethylene Note: The shape of the adhesive tape shown above is for securing the F03-16PE. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 1 Sensing Band F03-16PT * Compared to the F03-16PE (polyethylene), the F03-16PT has higher resistance to both high temperatures and chemicals. * Small holes enable the detection of leakage even when installed upside down. Ordering Information Name Model number Remarks Fluoroplastic Sensing Band F03-16PT --- Fluoroplastic Sensing Band Stickers F03-26PTN 10 Stickers per set Specifications Sheath PTFE fluoroplastic Core SUS316 stainless steel Ambient operating temperature -50 to 200qC Weight Approx. 16 g (1 m) Dimensions (Unit: mm) Sensing Band Appearance Structure 1.7 1.2 10 5 2.7 19/0.12 x 0.6t SUS316 Materials: Electrodes: SUS316 stainless steel, Sheath: Fluoroplastic Sensing Band Stickers F03-26PTN (screws) Appearance Structure 25 12 15 Two, 3.5 dia. 3.0 Material: Fluoroplastic PTA Note: The shape of the adhesive tape shown above is for securing the F03-16PE. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 2 Sensing Band F03-15 * Ideal for harsh electrical room environments that are dusty and humid. * For installation in locations requiring insulated materials. Ordering Information Name Model number Remarks Liquid Leakage Sensing Band F03-15 --- Sensing Band Stickers F03-25 30 Stickers per bag Specifications Sheath Flexible, transparent vinyl chloride Core SUS304 stainless steel Ambient operating temperature 15 to 50qC Weight Approx. 48 g (1 m) Dimensions (Unit: mm) Sensing Band Appearance Structure (Stainless steel wire 0.3 mm x 12-wire braided cable) Electrode pairs 8 25 Flexible, transparent vinyl chloride 333 (3 pairs/m) Sensing Band Stickers F03-25 Appearance Structure 252 (0.5) (5) (3) 151 Adhesive tape (1) Material: SUS304 http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 3 F03-15 Chemical Resistivity for F03-16PE/-16PT Material Sheath Polyethylene Core Fluoroplastic Material SUS316 Sheath Polyethylene Fluoroplastic Core SUS316 Water A A A Toluene C B B Acetone C A A Phenol B B A Ammonia A A A Butanol B A --- Ethanol B A A Fluorine A A C Hydrochloric acid A A C Hexane C A --- Hydrogen peroxide solution A A A Benzene C A A Xylene B A A Methanol B A A Cyclohexane C A --- Sulfuric acid C A B Trichloroethylene C A A Phosphoric acid A B B Note: 1. A: Not affected at all or only very slightly affected. B: Slightly affected but, depending on the conditions, sufficient for use. C: Affected but may still be used. (Replace the Sensing Band immediately after detection.) 2. The F03-16PE Sensing Band is made from the following materials. Core: SUS316 Insulated sheath: Polyethylene 3. In order to prevent secondary fire damage, consider the effect of the atmosphere of the environment and the solution to be detected on the Sensing Band. 4. If the Sensing Band changes shape or color when a liquid is detected, replace the Sensing Band. Connecting the Sensing Band Bending the Sensing Band Interval Between Stickers To change the direction of the Sensing Band, bend the Sensing Band in one or two places where the core is not exposed. When securing the Sensing Band with Stickers, attach the Stickers at intervals of 20 to 30 cm in places where the core is not exposed. 20 to 30 cm Bent in 1 place Bent in 2 places Note: Bend the Sensing Band approximately 4 cm (i.e., twice the distance between places where the core is exposed) away from places where a Sticker is attached. If the Sensing Band is bent at places further away than this, the Sensing Band may come away from the surface. Stripping and Connecting Terminals 1. Cut into the Sensing Band approximately 4 to 6 cm in from the end as shown in the diagram below. 2. Strip away approximately the last 9 mm of the sheath to expose the core (SUS line). 3. To connect to the Terminal Block, insert the screwdriver (see note 3) from the top of the Terminal Block and insert the stripped end of the core from the side. (Refer to Dimensions on page 1.) Sensing Band Sticker Note: 1. When using the F03-26PES (adhesive-tape model), be sure to wipe all moisture, oil, and dust from the surface to which the Sticker is to be attached. Failure to do so may result in insufficient adhesion, and the Sticker may peel away from the surface. 2. When using the F03-26PEN (screw model), before installing the Sensing Band, it is necessary to perform stud welding. For details on the pitch of the studs, refer to the information on the dimensions of Sensing Band Stickers. 3. Commercially available screwdrivers can be used. It is recommended, however, that either a 210-350/01 screwdriver or a 209-132 operating tool to connect jumpers, both manufactured by Wago Japan, is used. Contact http://www.wago.com. Insert 4 to 6 cm 9 mm Exposed part of core F03-20 Terminal Block Note: Check that the wiring is secure before using the K7L in applications. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 4 F03-15 Liquid Leakage Sensing Band Precautions Refer to the following installation methods and install the Sensing Band securely using the proper method for the location and environment. 1. Post or Beam Mounting Use fasteners, such as concrete anchors, to secure the Sensing Band every 500 to 1,000 mm to ensure that it does not come loose. If the surface of the post or beam is very uneven, apply two-sided tape to the mounting surface first and then secure the Sensing Band to the tape with the fastener. 2. Conduit Installation For vertical conduits, wrap the Sensing Band around the conduit at a pitch 2 to 3 times the diameter of the conduit. For horizontal conduits, secure the Sensing Band at appropriate intervals along the bottom of the conduit using an insulated adhesive strap, such as Insulock, to ensure that the Sensing Band does not come loose. 3. Dike and Catch Basin installation Use the specified stickers (sold separately) to secure the Sensing Band at appropriate intervals to keep it flat in the dike or catch basin. 4. Floor Installation Estimate the leakage detection area and use stickers to secure the Sensing Band at appropriate intervals on the floor and around equipment. Cover the Sensing Band with plastic or metal molding to protect it from contact with other objects and from being stepped on by workers. Leave a 50- to 100-mm gap in the molding at approximately 500-mm intervals where it touches the floor to allow liquids to pass through. 5. Do not install the Sensing Band in locations where condensation is likely to occur. 6. Mount the Sensing Band as close as possible to the mounting surface. Make sure that any gaps are no more than 2 mm in horizontal installations, such as the floor, and no more than 1 mm with vertical installations, such as posts and beams. 7. Attach an insulated protector, such as plastic molding, securely to the Sensing Band to protect it from contact with power cables carrying over 300 V. 8. Normally leaking materials detected by the Sensing Band will evaporate and the Sensing Band will return to its original state. The Sensing Band may not return to its original state and will have to be replaced, however, if the leaking material contained conductive impurities. Follow the appropriate replacement procedures. 9. The Sensing Band is not designed to be used as electrical wiring and must not be used for any purpose other than leak detection. 10.Do not apply petroleum-based products, such as wax, to the Sensing Band. Otherwise, liquids may be repelled and detection may fail. Dimensions (Unit: mm) Liquid Leakage Point Sensor F03-16PS F03-16PS-F 8 10 2 Electrode Overall length 2,000 mm Sheath: Fluoroplastic, 0.66 dia. 32 dia. 5.5 dia. 2.6-dia. vinyl-insulated round cable with 2 conductors, Conductor cross section: 0.079 mm2 Note: 1. The Terminal Block is made of nylon 66. Mount the Terminal Block in locations not subject to liquid chemicals using M3 screws. 2. Secure the Sockets with M3 screws at a torque of 0.78 to 1.18 Nm. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 5 F03-15 Point Sensor Mounting Bracket F03-26PS R5 10 19.2 1 24 1 8.85 3 R3 22.5 12 6 dia. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 6 F03-15 FAQs Some questions that are frequently asked about the K7L are given below. Use this information when selecting a model. Can one K7L Amplifier be used for detection in more than one place? Yes. By using Terminal Blocks to connect Sensing Bands in parallel, detection can be performed in more than place with only one K7L Amplifier. Total: 400 m max. Can a different terminal block (e.g. a commercially available terminal block or a terminal block constructed by the user) be used instead of the one provided? Yes. When using another terminal block, however, be sure to check that all the terminals are mutually isolated, and that there is no danger of ground faults in connecting cables or Sensing Bands. Terminal TerminalBlocks Block K7L-U Can the K7L Amplifier detect pure water? Yes. Note: 1. When wiring, be sure not to exceed the maximum possible wiring distances for both the connecting cable and the Sensing Band. Exceeding these distances may lead to faulty operation. Connect one Sensing Band to each Terminal Block. 2. Not applicable to the K7L-UD. Even pure water, which has a resistance exceeding 10 M:cm, can nearly always be detected if the K7L is used at its maximum sensitivity. This is because impurities are mixed with the water when it is leaked and the resistance drops. Pure water Impurities in the air Can the K7L Amplifier be used as a replacement for the 61F-GPN-V50 Water Leakage Detector? Can the K7L Amplifier detect oil? Yes. Because the surge withstand capability is different, however, do not use in locations where it will be exposed to impulses and surges, such as outdoor roofs or in pump panels. Also, items such as the power supply voltage and the connection sockets are different. Check these items before application. No. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 7 Liquid Leakage Point Sensor F03-16PS A New Liquid Leakage Point Sensor Has Been Added to the K7L Series. Fluoroplastic Coating on the Bottom Electrode Ensures Chemical Resistance. * * * * Can be used in conjunction with Sensing Bands. Stud screw mounting requires no tools for installation. No tools means the Sensor can be wiped clean quickly and easily. The optional Mounting Bracket enables faster installation than three-screw mounting. * Connect multiple Sensors to one K7L Amplifier for significant cost savings. Ordering Information Sensors Product name Main material Liquid Leakage Point Sensor Polyethylene Mounting Brackets (See note 1.) Terminal Block (See note 2.) Nylon 6.6 Cable material Electrode material Model Outer sheath: PVC Inner sheath: Fluoroplastic SUS304 F03-16PS SUS304 and fluoroplastic coating F03-16PS-F --- --- F03-26PS --- --- F03-20 Note: 1. Use a commercially available bonding agent for PVC. One bag contains 10 Brackets. 2. One bag contains 10 Blocks. Amplifier Product name Model Liquid Leakage Sensor Amplifier K7L-U Specifications Wiring Diagram Material Sensor Amplifier Any number of Sensors can be connected in parallel up to an overall cable length of 400 m. Leakage areas cannot be specified with the K7L. Polyethylene Conductor Outer sheath: PVC, Inner sheath: Fluorine resin Core F03-16PS: SUS304 stainless steel F03-16PS-F: SUS304 and fluorine coating Ambient operating temperature range 10 to 60qC Weight Approx. 30 g Maximum number of Point Sensors connected per Amplifier Any number up to an overall cable length of 400 m. Applicable Amplifier K7L-U (excluding Liquid Leakage Sensor Amplifier with disconnection detection function) 5 6 7 4 3 2 8 1 K7L-U Liquid Leakage Sensor Amplifier 4 3 2 4 3 2 F03-16PS Liquid Leakage Point Sensor 4 3 2 4 3 2 4 3 2 4 3 2 F03-16PS Liquid Leakage Point Sensor Sensing Band F03-20 Terminal Block Overall cable length: 400 m max. Mounting Methods Stud Screw Mounting Securing the Sensor with a Nut Special Bracket Mounting Securing the Sensor with a Wing Nut (See note.) Note: Use a commercially available bonding agent for PVC. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 8 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased product. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERRORS AND OMISSIONS The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. COPYRIGHT AND COPY PERMISSION This catalog shall not be copied for sales or promotions without permission. This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety. 2007. 3 OMRON Corporation In the interest of product improvement, specifications are subject to change without notice. Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: F03-26PES