VALU-BEAM SMI912 Series Intrinsically safe dc sensor * * * * * * * SMI912 Series sensor, with CI3RC2 current amplifier module (left) and intrinsic safety barrier (right) * * Offers economy, performance and reliability in a rugged housing Provides standard limit-switch mounting hole spacing Use with approved intrinsically safety barriers and Banner MAXI-AMPTM model CI3RC2 current trip point amplifier Certified for use in all Classes, Groups, and Divisions of hazardous locations as defined by Article 500 of the National Electrical Code when used with approved I.S. barriers Provides 10 to 30 V dc supply voltage with NPN output Features a light- or dark-operate selection switch Available in opposed, polarized and non-polarized retroreflective, diffuse, convergent, and glass or plastic fiber optic sensing modes Ranges up to 60 meters Integral 3-pin Mini-style QD fitting; QD cordset required, see Accessories Sensing Mode OPPOSED Models Range Long-range opposed, 880 nm SMI91EQD Emitter Effective Beam: 13 mm (0.5 in) SMI91RQD Receiver Short-range opposed, 880 nm SMI91ESRQD Emitter Effective Beam: 3.5 mm (0.14 in) SMI91RSRQD Receiver Non-polarized retroreflective, 650 nm Visible Red SMI912LVQD 150 mm to 9 m (6 in to 30 ft)1 Polarized retroreflective, 650 nm Visible Red SMI912LVAGQD 300 mm to 4.5 m (1 to 15 ft) 1 Models Range Long-range diffuse, 880 nm Infrared SMI912DQD 760 mm (30 in) Short-range diffuse, 880 nm Infrared SMI912DSRQD 380 mm (15 in) 60 m (200 ft) 3 m (10 ft) RETRO P POLAR RETRO Sensing Mode DIFFUSE Focus at: 38 mm (1.5 in) Convergent, 650 nm Visible Red SMI912CVQD Plastic fiber optic, 650 nm Visible Red SMI912FPQD CONVERGENT VISIBLE RED Spot Size at Focus: 1.5 mm (0.06 in) PLASTIC FIBER Glass fiber optic, 880 nm Infrared Glass fiber optic, 880 nm Infrared SMI912EFQD Emitter SMI912RFQD Receiver See performance curves SMI912FQD GLASS FIBER 1 Performance based on use of a model BRT-3 retroreflector (3-inch diameter). Actual sensing range may be more or less than specified, depending on the efficiency and reflective area of the retroreflector used. Original Document 03396 Rev. M 6 November 2014 03396 VALU-BEAM SMI912 Series WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Overview VALU-BEAM SMI912 Series sensors are designed for intrinsically safe operation in hazardous atmospheres. They are certified by FM Approvals and CSA as being intrinsically safe when used with approved intrinsic safety barriers. SMI912 Series sensors may be wired for either two- or three-wire current-sinking operation. In the three-wire hookup, which requires two intrinsic-safety barriers, the sink current is 15 mA. The two-wire hookup, which requires one barrier, sinks 10 mA (OFF state) and 20 mA (ON state). Brown Regulator Sens. +10 to 30V dc L.0. Receiver Demodulator Amp D.0. AID Oscillator Black Current Current Sense Output 36V 27 Ohms Blue Emitter Common SMI912 Series sensors feature rugged, encapsulated construction, along with adjustable sensitivity and switchable light or dark operate. They also include Banner's exclusive Alignment Indicating Device system, which lights an indicator LED whenever the sensor "sees" its modulated light source, and pulses at a rate proportional to the received light signal strength. Intrinsic safety barriers and current trip point amplifier model CI3RC2 are also available (see Accessories). Installation Notes WARNING: Explosion Hazard Do not disconnect equipment unless power has been switched Off or the area is known to be nonhazardous. FM Installation 1. Barriers must be installed in accordance with manufacturer's instructions. 2. Barrier entity parameters must meet the following requirements: * * Voc or Vt Vmax Ca Ci + Ccable Isc or It I max La Li + Lcable 3. Maximum non-hazardous area voltage must not exceed 250V. 4. For guidance on installation, see ANSI/ISA RP12.6, "Installation of Intrinsically Safe Instrument Systems for Hazardous (Classified) Locations." 5. The sensors are suitable for installation without barriers in Class I Div. 2 Groups A, B, C, D; Class II Div. 2 Group G; and Class III Div. 2, when installed in (or through the wall of) a suitable enclosure with provision for connection of rigid metal conduit per the National Electrical Code, as acceptable to the local inspection authority having jurisdiction. 2 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 03396 Rev. M VALU-BEAM SMI912 Series CSA Installation 1. Barriers must be installed in accordance with manufacturer's instructions. 2. Barrier entity parameters must meet the following requirements: * * Voc Vmax Ca Ci + Ccable Isc I max La Li + Lcable 3. Maximum non-hazardous area voltage must not exceed 250V. 4. Install in accordance with Canadian Electrical Code, Part I. 5. The sensors are suitable for installation without barriers in Class I Div. 2 Groups A, B, C, D when installed in (or through the wall of) a suitable enclosure with provision for connection of rigid metal conduit per the Canadian Electrical Code, as acceptable to the local inspection authority having jurisdiction. In Div. 2 installations (without barriers), observe warning at left. 6. If barriers with Volt/Ohm parameters are used, the following parameters shall apply: One Single-Channel Barrier Systems * one 28 V (max), 300 (min) Two Single-Channel Barrier or One Dual-Channel Systems * * * two 28 V (max), 600 (min) one 28 V (max), 300 (min) and one 10 V (max), 50 (min) one 28 V (max), 300 (min) and one 28 V diode return Sensor Entity Parameters * * * * * Vmax (Ui) 30V dc Imax (li) 350 mA Pi 750 mW Ci = 0 F Li = 0 mH Wiring Connections SMI912 Series sensors are certified intrinsically safe ONLY when used with certified energy-limiting intrinsically safe barriers. Banner does not manufacture such barriers; however, our applications engineers can refer you to suppliers of certified barriers that will interface with Banner sensors. SMI912 Series sensors may be wired using Banner Current Amplifier Control Module CI3RC2. Note from the wiring diagrams that the installation may be made with either a single barrier (2-wire hookup) or with a double barrier (3-wire hookup). Emitter-only units (SMI91EQD, ESRQD, and EFQD) use the 2-wire hookup; all other models use either 2- or 3-wire hookup. In the 2-wire configuration, the sensor will act as a current sink, drawing less than 10 mA in the OFF state and more than 20 mA in the ON state. The user must provide a current sensing device ("current sensor" in the diagram) to convert the current to a logic level. In the 3-wire configuration, the output may be used directly to control loads of less than 15 mA. In selecting the barrier, it is important to consider the barrier's resistance. The sensor must have at least 10 volts across the brown and blue power leads for proper operation, and the barrier will cause a voltage drop due to its resistance. The formula that determines how much resistance is allowed is: R = 40 (supply voltage - 10 volts). If the supply voltage is 24 V dc, then the maximum resistance is 560 ohms. If the supply voltage is 18 V dc, then the maximum resistance is 320 ohms. This includes the resistance of any current sensing device used (in the 2-wire configuration), so the barrier resistance must be further reduced by the current sensor resistance. Note that, in the 3-wire hookup, the positive load barrier is in series with the load. This will result in an apparent saturation voltage of the output that is higher than the sensor output by the amount of I x R (current times resistance) drop through the barrier. A "positive input" barrier is required for both supply and for load. The sensor's blue (negative supply) lead is normally connected to the ground terminal of the barrier. The user is responsible for proper installation and maintenance of this equipment, and must conform with the certification requirements relating to barriers and to maximum allowable capacitance and inductance of the field wiring. If in doubt about these requirements, our applications engineers can refer you to the appropriate authority. P/N 03396 Rev. M www.bannerengineering.com - Tel: +1-763-544-3164 3 VALU-BEAM SMI912 Series CAUTION: Electrostatic Discharge (ESD) Special Conditions for Safe Use. Parts of the enclosure are non-conducting and may generate an ignition-capable level of ESD. Cleaning of the equipment shall be done only with a damp cloth. Safe area Barriers not required for Div. 2 30 V dc (reference NOTE #5 for FM & CSA on page 3) Hazardous area + + IN L O A D OUT BLACK I.S. - 15 mA max. V 3 IN + + + 4 SMI900 Series Sensor 2 3 OUT Bottom view (colors shown are for mating cordset MBCC-312) BROWN Operating Voltage INPUT 18-30 V dc 25 mA dc - Connection to control room equipment should not use or generate more than 250 V Blue G Busbar Earth ground (less than 1 ohm) Note: Emitters have no output connection (no connection to black wire) Figure 1. Wiring for 3-Wire Connections Safe area Hazardous area Barriers not required for Div 2 30 V dc max. (Reference Note #5 for FM & CSA) + + IN BLACK I.S. - - V 4 10 mA (OFF state) 20 mA (ON state) + OUT 2 3 2 3 SMI900 Series Sensor Barrier BROWN Sensor Operating voltage 18-30 V dc Input 25 mA dc - G Earth ground (less than 1 ohm) Bottom view (colors shown are for mating cordset MBCC-312) Blue BUSBAR Figure 2. Wiring for 2-Wire Connections 4 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 03396 Rev. M VALU-BEAM SMI912 Series Specifications Supply Voltage and Current Sensor only: requires 10 to 30 V dc, 25 mA maximum Output Configuration Current sinking NPN open-collector transistor Sensing Beam Infrared (880 nm) or visible red (650 nm), depending on model Output Rating Three-wire hookup sinks 15 mA maximum, continuous (10 to 30 V dc) Two-wire hookup sinks 10 mA (OFF state) and 20 mA (ON state), 10 to 30 V dc. Outputs are short-circuit protected. Adjustments Light/Dark Operate select switch on rear of sensor Sensitivity control on rear of sensor allows precise gain setting (turn clockwise to increase gain) Indicators Sensors include Banner's exclusive Alignment Indicating Device (AIDTM) system, which lights a top-mounted red indicator LED whenever the sensor "sees" its modulated light source, and pulses the LED at a rate proportional to the received light signal strength. Output Response Time Opposed-mode receivers: 8 milliseconds ON/4 milliseconds OFF; independent of signal strength All other models: 4 milliseconds ON and OFF 100 millisecond delay on power-up (output does not conduct during this time). Construction Housing: reinforced PBT, totally encapsulated Lenses: molded acrylic Hardware: stainless steel Repeatability Opposed mode: 1.0 millisecond All other modes: 1.3 milliseconds Repeatability is independent of signal strength. Connections Supplied with integral 3-pin Mini-style QD fitting; requires cordset model MBCC (see Accessories), purchased separately. Environmental Ratings Banner tested to NEMA standards 1, 2, 3, 3S, 4, 4X, 12, and 13, IEC IP66 Application Note Special Conditions for Safe Use: Parts of the enclosure are nonconducting and may generate an ignition-capable level of ESD. Cleaning of the equipment shall be done only with a damp cloth. Operating Conditions Temperature: -20 C to +70 C (-4 F to +158 F) Max. Relative Humidity: 90% @ 50 C (non-condensing) Certifications Design Standards ATEX (European) EN 60079-0, EN 60079-11, EN 60079-26 Canadian CAN/CSA C22.2, No. 142-M1987, No.157-92, No. 1010.1, E60079-0, E60079-11 United States FM Class 3600, 3610, and 3810, ANSI/ISA 61010-1 (82.02.01), ANSI/ISA 60079-0, 60079-11, and 60079-26. IECEx IEC 60079-0 (Ed.6.0); IEC 60079-11 (Ed. 6.0) Approvals ATEX (European) II 2 G Ex ib IIC T5 Gb Ta = -40 C to 70 C - 03396; Entity FM12ATEX0094X Entity Parameters: VMax = 30 V, IMax = 350 mA, Ci = 0 F, Li = 0 mH. Canadian SMI91(a) Non-incendive for Class I, Division 2, Groups A, B, C and D, T5 Ta = -40 C to 70 C a = 2LVQD, 2DQD, 2DSRQD, 2FQD, 2CVQD, 2LVAGQD or 2FPQD. SMI91(b) Non-incendive for Class I, Division 2, Groups A, B, C and D, T5 Ta = -40 C to 70 C Intrinsically safe for Class I, Zone 1 Ex ib Group IIC T5 Ta = -40 C to 70 C; - 03396, Entity Entity Parameters: VMax = 30 V, IMax = 350 mA, Ci = 0 F, Li = 0 mH. b = 1RQD, RSRQD, RFQD, EQD, ESRQD or EFQD. United States SMI91(a) Non-incendive for Class I, Division 2, Groups A, B, C and D, T5 Ta = -40 C to 70 C Suitable for Class II and III, Division 2, Groups F and G*, T5 Ta = -40 C to 70 C a = 2LVQD, 2DQD, 2DSRQD, 2FQD, 2CVQD, 2LVAGQD or 2FPQD. SMI91(b) Non-incendive for Class I, Division 2, Groups A, B, C and D, T5 Ta = -40 C to 70 C Suitable for Class II and III, Division 2, Groups F and G*, T5 Ta = -40 C to 70 C Intrinsically safe for Class I, Zone 1 AEx ib Group IIC T5 Gb Ta = -40 C to 70 C - 03396; Entity Entity Parameters: VMax = 30 V, IMax = 350 mA, Ci = 0 F, Li = 0 mH. b = 1RQD, RSRQD, RFQD, EQD, ESRQD or EFQD. IECEx P/N 03396 Rev. M Ex ib IIC T5 Ta= -40 C to +70 C - 03396; Entity - IECEx FMG 14.0029X Entity Parameters: Vmax = 30 V, Imax = 350 mA, Ci=0 f, Li=0 mH www.bannerengineering.com - Tel: +1-763-544-3164 5 VALU-BEAM SMI912 Series VALU-BEAM (R) INSTALL PER MFG. DWG. 03396 MODEL: XXXXXXXXXXXXXXXXX NRTL/C LR41887 Exia INTRINSICALLY SAFE/ SECURITE INSTRINSIQUE Imax (li) = 350mA Vmax (Ui) = 30VDC Ci = 0 Li = 0 FOR HAZARDOUS LOCATIONS, INSTALL PER MFG. DWG. 03396 XXXXX 1725 VALU-BEAM (R) MODEL: XXXXXXXXXXXXXXXXX Imax (li) = 350mA Vmax (Ui) = 30VDC Ci = 0 Li = 0 XXXXX NRTL/C LR41887 Exia FM12ATEX0094X II 2 G Ex ib IIC T5 Gb Ta = -40C to +70C CL I, ZN 1 AEx/Ex ib IIC T5 Gb CL I, DIV 2 GP ABCD (CL II, III, DIV 2 GP EF US only) IECEx FMG 14.0029X Ex ib IIC T5 INTRINSICALLY SAFE/ SECURITE INSTRINSIQUE CL I, DIV 2 GP ABCD (CL II, III, DIV 2 GP EF US only) Performance Curves Opposed Excess Gain Beam Patterns Excess Gain Long-range Opposed Short-range Opposed 1000 1000 E X C E S S G A I N 1500 mm 100 Beam Patterns SMI91EQD & SMI91RQD SMI91EQD/SMI91RQD 40 " 500 mm 20 " 0 10 0 500 mm 20 " 1000 mm 40 " 1500 mm 60 " 0 1 .1 m .33 ' 1m 3.3 ' 10 m 33 ' 60 " 1000 mm 100 m 330 ' 15 m 50' 30 m 45 m 100' 150' DISTANCE 60 m 200' E X C E S S G A I N 100 300 mm 12 " 200 mm 8" 100 mm 10 SMI91ESRQD & SMI91RSRQD 4" 200 mm 8" 12 " 300 mm 0 .01 m .033 ' .1 m .33 ' 0 100 mm 1 75 m 250' 4" SMI91ESRQD/ SMI91RSRQD 0 1m 3.3 ' 10 m 33 ' 0.6 m 2' 1.2 m 1.8 m 4' 6' DISTANCE 2.4 m 8' 3.0 m 10' DISTANCE DISTANCE Retroreflective Retroreflective performance based on use of a model BRT-3 retroreflector (3" diameter). Actual sensing range may be more or less than specified, depending on the efficiency and reflective area of the retroreflector used. Excess Gain Beam Patterns Excess Gain Non-polarized Retroreflective 1000 E X C E S S G A I N with 3" reflector (BR T-3) with 1" reflector (BR T-1) .01 m .033' .1 m 1m .33' 3.3' DISTANCE 100 mm 4" 50 mm 2" 0 0 50 mm 2" 100 mm 4" with BRT-3 REFLECTOR 0 10 m 33' 6" SMI912LVQD 150 mm with BR T-T tape 1 6 1000 100 10 Polarized Retroreflective SMI912LVQD 150 mm 2m 9' 4m 6m 15' 21' DISTANCE Beam Patterns 8m 27' 6" 10 m 33' E X C E S S G A I N SMI912LVAGQD 75 mm 100 with BRT-3 3" retroreflector 10 3" SMI912LVAGQD 50 mm 2" 25 mm 1" 0 0 25 mm 1" 50 mm 2" with BRT-3 REFLECTOR 75 mm 0 1 .01 m .033 ' .1 m 1m .33 ' 3.3 ' DISTANCE www.bannerengineering.com - Tel: +1-763-544-3164 10 m 33 ' 1m 3' 2m 3m 6' 9' DISTANCE 4m 12' 3" 5m 15' P/N 03396 Rev. M VALU-BEAM SMI912 Series Diffuse Diffuse mode performance based on use of 90% reflectance white test card. Excess Gain Beam Patterns Excess Gain Long-range Diffuse Short-range Diffuse 1000 1000 SMI912DSRQD SMI912DQD E X C E S S SMI912DQD 19.5 mm Range is based on 90% reflectance white test card 100 10 .50" 6.5 mm .25" 0 6.5 mm .25" 13 mm .50" 19.5 mm .75" 0 1 1 mm .04 " 10 mm .4 " 100 mm 4" E X C E S S .75" 13 mm 0 G A I N Beam Patterns 160 mm 6" 1000 mm 40 " 310 mm 460 mm 12" 18" DISTANCE 610 mm 24" G A I N Range is based on 90% reflectance white test card 100 .75" 13 mm .50" 6.5 mm 10 10 mm .4 " 100 mm 4" 0 6.5 mm .25" 13 mm .50" 19.5 mm .75" 75 mm 3" 0 1 mm .04 " .25" SMI912DSRQD 0 1 760 mm 30" 19.5 mm 1000 mm 40 " 150 mm 225 mm 6" 9" DISTANCE 300 mm 12" 375 mm 15" DISTANCE DISTANCE Convergent Excess Gain 1000 E X C E S S G A I N Beam Pattern SMI912CVQD Convergent Mode SMI912CVQD 2.4 mm 100 0.09" Convergent Mode 1.6 mm 0.06" 0.8 mm 0.03" 0 10 0 0.8 mm 0.03" 1.6 mm 0.06" 2.4 mm 0.09" 0 1 1 mm .04" 10 mm .4" 100 mm 4" 15 mm 0.60" 30 mm 1.2" 45 mm 1.8" 60 mm 2.4" 75 mm 3.0" DISTANCE 1000 mm 40" DISTANCE Plastic Fiber Optic Excess Gain Beam Pattern Excess Gain Plastic Fiber Optic (Opposed) Plastic Fiber Optic (Diffuse) 1000 1000 SMI912FPQD SMI912FPQD E X C E S S G A I N Beam Pattern SMI912FPQD Opposed Mode 45 mm Opposed mode plastic fibers 30 mm 100 15 mm with PIT46U No Lenses with PIT46U Lenses 10 with PIT26U No Lenses 1 PIT26U 0 10 mm .4 " 100 mm 4" DISTANCE P/N 03396 Rev. M 1000 mm 40 " PIT46U 1.2" 0.6" 0 15 mm 0.6" 30 mm 1.2" 45 mm 1.8" 0 1 mm .04 " 1.8" 25 mm 1" 50 mm 75 mm 2" 3" DISTANCE 100 mm 125 mm 4" 5" E X C E S S G A I N 100 SMI912FPQD - Diffuse Mode 3.75 mm Diffuse mode plastic fiber Range is based on 90% reflectance white test card. 2.50 mm .10" 1.25 mm .05" PBT26U 0 with PBT46U fiber 10 PBT46U 0 1.25 mm .05" 2.50 mm .10" 3.75 mm with PBT26U fiber 1 .1 mm .004 " 1 mm .04 " .15" 0 10 mm .4 " 100 mm 4" .15" 7.5 mm 0.3" 15.0 mm 22.5 mm 0.6" 0.9" DISTANCE 30.0 mm 1.2" 37.5 mm 1.5" DISTANCE www.bannerengineering.com - Tel: +1-763-544-3164 7 VALU-BEAM SMI912 Series Glass Fiber Optic Excess Gain Beam Pattern Excess Gain Beam Pattern Glass Fiber Optic (Opposed) 1000 1000 E X C E S S G A I N SMI91EFQD SMI91RFQD 100 SMI91EFQD/SMI91RFQD 75 mm Opposed mode glass fibers IT23S fibers IT13S IT13S fibers 0 25 mm 1" 50 mm 2" 75 mm 3" 1 0 100 mm 4" 1" IT23S 0 10 10 mm .4 " 2" 50 mm 25 mm 1 mm .04 " 3" 1000 mm 40 " 100 mm 4" 200 mm 300 mm 8" 12 " DISTANCE 400 mm 16 " SMI91EFQD SMI91RFQD E X C 100 E S S G A I N 200 mm 100 mm 10 m 33' E X C E S S G A I N SMI912FQD 75 mm Opposed mode glass fibers IT23S fibers 2" 25 mm IT23S fibers IT13S fibers 1" IT23S fibers 0 0 25 mm 1" 50 mm 2" 75 mm 3" 1 0 100 mm 4" 3" 50 mm 100 10 mm .4 " 100 m 330' 5.0 m 7.5 m 16' 24' DISTANCE 10.0 m 32' 12.5 m 40' Glass Fiber Optic (Retro) 1000 1 mm .04 " 12 " 2.5 m 8' DISTANCE SMI912FQD 10 0 8" 0 1m 3.3' 4" 4" 300 mm 1 .1 m .33' 8" IT23S fibers with L16F Lenses 200 mm Glass Fiber Optic (Opposed) 1000 100 mm IT23S and L9 Lenses DISTANCE 12 " IT23S fibers with L9 Lenses 0 IT23S and L16F Lenses 10 500 mm 20 " SMI91EFQD/ SMI91RFQD 300 mm 1000 mm 40 " 100 mm 4" 200 mm 8" 300 mm 12" 400 mm 16" E X C E S S SMI912FQD Retroreflective model with BRT-3 3" target G A I N 4" w/L16F lens w/L9 lens 0 50 mm 10 with L9 lens and BT13S fibers DISTANCE .1 m .33' BT13S fiber, retroreflective mode, with BRT-3 reflector 150 mm 1m 3.3' 10 m 33' 2" 0 2" 100 mm 0 .01 m .033' DISTANCE 6" 50 mm 1 500 mm 20" SMI912FQD 150 mm 100 mm with L16F lens and BT13S fibers 100 1.25 ' m 4' 2.50 m 8' 3.75 m 12' 5.00 m 16' 4" 6" 6.25 m 20' DISTANCE DISTANCE Glass Fiber Optic (Diffuse) 1000 E X C E S S G A I N SMI912FQD 2.4 mm .1" 1.8mm Diffuse mode Range is based on 90% reflectance white test card 100 0.6 mm with BT13S fibers BT23S BT13S 0 with BT23S fibers 10 SMI912FQD Diffuse Mode 1.2 mm 10 mm .4 " 0 .025" .050" .075" 0 1 mm .04 " .025" 1.2 mm 2.4 mm 0.1 mm .004 " .050" 0.6 mm 1.8 mm 1 .075" 100 mm 4" 7.5 mm .3" 15.0 mm 22.5 mm .6" .9" DISTANCE .1" 30.0 mm 37.5 mm 1.2" 1.5" DISTANCE Dimensions LED Indicator 36.6 mm (1.44") Light/Dark Operate Select (L.O. = CW, D.O. = CCW) 35.6 mm (1.40") Lens Centerline 50.8 mm (2.00") Sensitivity Control (Turn CW to Increase) 39.1 mm (1.54") 17.8 mm (0.70") 4.5 mm (#10) Screw Clearance (2) 26.7 mm (1.05") Mini-style Quick-disconnect 8 5.6 mm (0.22") M30 x 1.5 Thread Hex Nut Supplied Control potentiometers are behind cover screws; remove screws to access controls 25.4 mm (1.00") www.bannerengineering.com - Tel: +1-763-544-3164 P/N 03396 Rev. M VALU-BEAM SMI912 Series Accessories 3-Pin Mini-Style Cordsets Model Length MBCC-306 1.83 m (6.5 ft) MBCC-312 3.66 m (12 ft) MBCC-330 9.14 m (30 ft) SMICC-306 1.83 m (6.5 ft) SMICC-312 3.66 m (12 ft) SMICC-330 9.14 m (30 ft) SM30CC-306 1.83 m (6.5 ft) SM30CC-312 Style Dimensions Pinout (Female) Straight 1 52 Typ. Straight 7/8-16UN-2B 2 3 1 = Black 2 = Brown 3 = Blue o 25.5 1 = Red/Black 2 = Red/White 3 = Green Straight 3.66 m (12 ft) Mounting Brackets SMB30A * Right-angle bracket with curved slot for versatile orientation * Clearance for M6 (1/4 in) hardware * Mounting hole for 30 mm sensor * 12-ga. stainless steel 45 C 61 B A 69 57 70 C 57 B A Hole center spacing: A = 51, A to B = 25.4 Hole size: A = 42.6 x 7, B = o 6.4, C = o 30.1 Hole center spacing: A to B=40 Hole size: A=o 6.3, B= 27.1 x 6.3, C=o 30.5 SMB30SC * Swivel bracket with 30 mm mounting hole for sensor * Black reinforced thermoplastic polyester * Stainless steel mounting and swivel locking hardware included SMB30MM * 12-ga. stainless steel bracket with curved mounting slots for versatile orientation * Clearance for M6 (1/4 in) hardware * Mounting hole for 30 mm sensor 67 B 58 29 A Hole center spacing: A=o 50.8 Hole size: A=o 7.0, B=o 30.0 Current Trip-Point Modules Current Trip-Point Module Model CI3RC2 P/N 03396 Rev. M Description * Self-contained module converts the SMI912 sensor's current output signal to a trip point switch. * SPDT electromechanical relay switches loads that draw up to 5 amps. The SPST solid-state relay can switch a dc load of up to 30 V dc, max.; 20 mA max. * Powered by either 105 to 130 V ac or 210 to 250 V ac. * Supplies dc power to operate a single sensor or both the emitter and receiver of one SMI Series opposed-mode sensor pair. The sensor's input to the CI3RC2 is protected against short circuits. Built-in circuit diagnostics indicate an input overload by flashing an LED status light. * Module has two isolated output switches, a 5-amp rated SPDT electromechanical relay and a solid-state transistor switch used for logic-level interfaces. * May be ordered either alone or as a part of a kit. www.bannerengineering.com - Tel: +1-763-544-3164 9 VALU-BEAM SMI912 Series Current Trip-Point Module Model Description Supply Voltage 105 to 130 V ac or 210 to 250 V ac, 50/60 Hz (8 VA) Output Configuration (SPDT electromechanical relay) Contact rating: 250 V ac maximum, 24 V dc maximum, 5 amps maximum (resistive load), 1/10 HP at 240 V ac. Install transient suppressor (MOV) across contacts which switch inductive loads. Min. load: 12 V dc, 0.1 A. Closure time: 10 milliseconds maximum. Release time: 10 milliseconds maximum. Maximum switching speed: 20 operations/second. Mechanical life: 20,000,000 operations Output Configuration (Solid-state dc relay) SPST optically-coupled transistor; 30 V dc maximum, 20 mA maximum. Emitter Power +24 V dc at 25 mA maximum available at module pin #3 Inputs Trip point for output "OFF": 10 mA Trip point for output "ON": 20 mA Trip point range for input overload indication: 30 mA I 80 mA Indicators Status Indicators for OUTPUT "ON" and INPUT overload/short Construction Housing: rugged polyphenylene oxide (PPO(R)) 1.6" x 2.3" x 4" Standard round-pin 11-pole base. Use RS-11 socket or equivalent. Operating Conditions Temperature: 0 C to +50 C (+32 F to +122 F) Intrinsic Safety Barriers Model (Barrier Only) Barrier Description Kit Model Kit Description CIB-1 Single-channel intrinsically safe barrier CI2BK-1 Includes CI3RC2 current amplifier, one RS-11 socket, one DIN-rail mount, one single-channel intrinsically safe barrier CI2B-1 Dual-channel intrinsically safe barrier (typically used in opposed-mode applications) CI2BK-2 Includes CI3RC2 current amplifier, one RS-11 socket, one DIN-rail mount, one dual-channel intrinsically safe barrier Safe Area Hazardous Area 4 IN + Dual Barrier + OUT SMI Series Emitter Brown 1 3 I.S. - - + + Blue Input: 10 mA (OFF state) 20 mA (ON state) Blue IN Aux. Relay outputs 5 amp contacts Black 4 Brown Common Busbar OPTO-Coupler Output: 20 mA max. 105 to 130V ac AC supply OUT Input CI3RC2 G 210 to 250V ac 1 3 SMI Series Receiver Bottom view of cordset connector on sensor (colors shown are for mating cordset model SMICC-312) Earth ground (less than 1 ohm) Figure 3. Wiring Connections - SMI912 Series Opposed Mode Emitters and Receivers 10 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 03396 Rev. M VALU-BEAM SMI912 Series Safe area Hazardous area Black Input: 10 mA (OFF state) 20 mA (ON state) 3 2 1 4 Relay outputs 5 amp contacts 105 to 130V ac AC supply 5 6 7 8 11 01 9 CI3RC2 Aux. 4 IN + + OUT Brown Input V Common - OPTO-Coupler Output: 20 mA max. I.S. Barrier 210 to 250V ac I.S. - 1 3 SMI Series Sensor Blue Bottom view of cordset connector on sensor (colors shown are for mating cordset model MBCC-312) Busbar G Earth ground (less than 1 ohm) Figure 4. Wiring Connections - All Other SMI912 Series Sensors Repairs and Translations Obtain assistance with product repairs by contacting your local Banner Engineering Corp distributor or by calling Banner directly at (763) 544-3164. Access literature translated into your native language on the Banner website at www.bannerengineering.com or contact Banner directly at (763) 544-3164. Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. www.bannerengineering.com - Tel: +1-763-544-3164